In order to investigate the effect of acid and antioxidant 2, 6-di-tert-butyl-p-cresol (DBPC) on the sulfur corrosion in oil, antioxidant DBPC and two kinds of acid were added into transformer oil which contains corrosive sulfur DBDS.Then the oil-paper insulation was experienced accelerated thermal aging under N2 environment.After the aging experiment, the copper winding was unfolded and the corrosion depositions on the copper and paper surface were observed.The GC-MS was used to measure the residual DBDS concentration in the oil.The activation energy of the corrosion reaction between DBDS and copper winding under the effect of acid was calculated using the Arrhenius equation.The results show that the corrosion degree of the copper conductor surface will be accelerated by acid; DBPC can mitigate the corrosion on copper surface to a certain extent; and Cu2S deposition can be hardly formed on the paper surface under N2 condition.In addition, the activation energy of the reaction between DBDS and copper winding is about 88.37 kJ/mol using the Arrhenius equation, whereas with the effect of the acid the activation energy decreased by almost 30.64%.The corrosion reaction between DBDS and copper winding will be easier to conduct under the effect of acid.
廖瑞金,胡恩德,杨丽君,黄加佳. 变压器油中酸与抗氧化剂协同作用对油硫腐蚀的影响[J]. 电工技术学报, 2016, 31(11): 204-210.
Liao Ruijin Hu Ende Yang Lijun Huang Jiajia. The Effect of Acid and DBPC on the Sulfur Corrosion Mechanism in Power Transformer. Transactions of China Electrotechnical Society, 2016, 31(11): 204-210.
[1] Wang M,Vandermaar A J.Review of condition assessment of power transformers in service[J].IEEE Transactions on Dielectrics and Electrical Insulation,2002,18(5):12-15.
[2] 刘捷丰,廖瑞金,吕彦东,等,电力变压器油纸绝缘含水量定量评估的时域介电特征量[J].电工技术学报,2015,30(2):197-201.
Liu Jiefeng,Liao Ruijin,Lü Yandong,et al.Time domain dielectric characteristic for quantitative assessment of moisture content in transformer oil-paper insulation[J].Transactions of China Electrotechnical Society,2015,30(2):197-201.
[3] 杨丽君,齐超亮,吕彦东,等.变压器油纸绝缘状态的频域介电特征参量及评估方法[J].电工技术学报,2015,30(1):213-218.
Yang Lijun,Qi Chaoliang,Lü Yandong,et al.Characteristic parameters and assessment method of frequency-domain dielectric spectroscopy of oil-paper insulation for transformers[J].Transactions of China Electrotechnical Society,2015,30(1):213-218.
[4] 高竣,廖瑞金,王有元,等.基于扩展Debye模型的变压器油纸绝缘老化特征量研究[J].电工技术学报,2016,31(4):212-215.
Gao Jun,Liao Ruijin,Wang Youyuan,et al.Ageing characteristic quantities of oil-paper insulation for transformers based on extended Debye model[J].Transactions of China Electrotechnical Society,2016,31(4):212-215.
[5] 郑君良,江修波,蔡金锭,等.去极化电力解谱分析油纸绝缘等效电路参数研究[J].电力系统保护与控制,2014,42(21):54-58.
Zheng Junliang,Jiang Xiubo,Cai Jinding,et al.Research on spectrum analysis of the depolarization current to identify the parameter of oil/paper insulation equivalent circuit[J].Power System Protection and Control,2014,42(21):54-58.
[6] 廖瑞金,刘捷丰,吕彦东,等,变压器油纸绝缘含水量定量评估的频域介电特征参量研究[J].电工技术学报,2015,30(1):205-210.
Liao Ruijin,Liu Jiefeng,Lü Yandong,et al.Frequency domain dielectric characteristic parameters for quantitative assessment of moisture content of oil-paper insulation in power transformers[J].Transactions of China Electrotechnical Society,2015,30(1):205-210.
[7] 林燕桢,蔡金锭.回复电压极化谱特征量与油纸绝缘变压器微水含量关系分析[J].电力系统保护与控制,2014,42(5):149-152.
Lin Yanzhen,Cai Jinding.Analysis of the relationship between the characteristic of the return voltage polarization spectrum and micro water content of oil-paper insulation transformer[J].Power System Protection and Control,2014,42(5):149-152.
[8] 赵云峰,张永强,宋友,等,基于模糊和证据理论的变压器本体绝缘纸状态评估方法[J].电力系统保护与控制,2014,42(23):58-62.
Zhao Yunfeng,Zhang Yongqiang,Song You,et al.Application of fuzzy and evidence theory in power transformers condition assessment[J].Power System Protection and Control,2014,42(23):58-62.
[9] Saha T K.Review of modern diagnostic techniques for assessing insulation condition in aged transformers[J].IEEE Transactions on Dielectrics and Electrical Insulation,2003,10(5):903-917.
[10]Emsley A M,Heywood R J,Ali M,et al.Degradation of cellulosic insulation in power transformers part 4:effect of aging on the tensile strength of paper[J].IEEE Proceedings-Science,Measurement and Technology,2000,174(6):285-290.
[11]Lundgaard L E,Hansen W,Linhjell D,et al.Aging of oil-impregnated paper in power transformers[J].IEEE Transactions on Power Delivery,2004,19(1):230-239.
[12]Rocha A H.Faults in 500 kV shunt reactors caused by corrosive sulfur in the insulation oil[C]//Proceedings of the Sixty-eighth Annual International Conference of Doble Clients,Insulation Materials Session,Boston,2001:1-10.
[13]钱艺华,胡红红,姚唯建.腐蚀性硫导致变压器故障的综合分析及处理[J].变压器,2008,45(1):28-30.
Qian Yihua,Hu Honghong,Yao Weijian.Analysis and treatment of transformer faulty caused by corrosive sulfur[J].Transformer,2008,45(1):28-30.
[14]Claes B,Mats D,Jan H,et al.Oil corrosion and conducting Cu2S deposition in power transformer windings[C]//IGRE Main Session,Paris,2006:1-4.
[15]CIGRE WG A2-32.Copper sulphide in transformer insulation,final report [R].GIGRE WG A2-32,2009.
[16]Maina R,Tumiatti V,Pompili M,et al.Corrosive sulfur effect in transformer oils and remedial procedures[J].IEEE Transactions on Dielectrics and Electrical Insulation,2009,16(6):1655-1663.
[17]Scatiggio F,Tumiatti V,Maina R,et al.Corrosive sulfur in insulating oils:its detection and correlated power apparatus failures[J].IEEE Transactions on Power Delivery,2008,23(1):508-509.
[18]Animoto T,Nagao E,Tanimura J,et al.Identification of affecting factors of copper sulfide deposition on insulating paper in oil[J].IEEE Transactions on Dielectrics and Electrical Insulation,2009,16(1):265-272.
[19]Kato F,Amimoto T,Nishiura R,et al.Suppressive effect and its duration of Triazole-based passivators on copper sulfide deposition on kraft paper in transformer[J].IEEE Transactions on Dielectrics and Electrical Insulation,2013,20(5):1915-1922.
[20]Amimoto T,Hosokawa N,Nagao E,et al.Concentration dependence of corrosive sulfur on copper sulfide deposition on insulating paper used for power transformer insulation[J].IEEE Transactions on Dielectrics and Electrical Insulation,2009,16(5):1489-1495.
[21]Kawarai H,Uehara Y,Mizuno K,et al.Influences of oxygen and 2,6-di-tert-butyl-p-cresol on copper sulfide deposition on insulating paper in oil-immersed transformer insulation[J].IEEE Transactions on Dielectrics and Electrical Insulation,2012,19(6):1884-1889.
[22]Lundgaard L E,Hansen W,lngebrigtsen S.Ageing of mineral oil impregnated cellulose by acid catalysis[J].IEEE Transactions on Dielectrics and Electrical Insulation,2008,15(2):540-546.
[23]Scatiggio F,Tumiatti V.Corrosive sulfur induced failures in oil-filled electrical power transformers and shunt reactors[J].IEEE Transactions on Power Delivery,2009,24(3):1240-1248.
[24]Toyama S,Tanimura J,Yamada N,et al.Highly sensitive detection method of dibenzyl disulfide and the elucidation of the mechanism of copper sulfide generation in insulating oil[J].IEEE Transactions on Dielectrics and Electrical Insulation,2009,16(2):509-515.
[25]Maina R,Tumiatti V,Pompili M,et al.Dielectric loss characteristics of copper contaminated transformer oils[J].IEEE Transactions on Power Delivery,2010,25(3):1673-1677.
[26]Kawarai H,Fujita Y,Tanimura J,et al.Role of dissolved copper and oxygen on copper sulfide generation in insulating oil[J].IEEE Transactions on Dielectrics and Electrical Insulation,2009,16(5):1430-1435.
[27]Toyama S,Mizuno K,Kato F,et al.Influence of inhibitor and oil components on copper sulfide deposition on kraft paper in oil-immersed insulation[J].IEEE Transactions on Dielectrics and Electrical Insulation,2011,18(6):1877-1882.
[28]Levine I N.Physical chemistry[M].New York:McGraw-Hill Science,Engineering and Math,2002.