电工技术学报  2015, Vol. 30 Issue (12): 336-343    DOI:
电力系统 |
基于多阶FDTD雷电感应过电压计算新方法
1,sup 于建立 sup 1,2 sup,詹清华3,王建国1,1,sup 蔡力 sup 1,sup 戚为 sup 4 sup
1. 武汉大学电气工程学院 武汉 430072;
2. 东北电力大学输变电技术学院 吉林 132012;
3. 广东电网公司 佛山 528000;
4. 国网宁波鄞州供电局 宁波 315100
New Method of Lightning Induced Over-voltage Based on Multiple Order FDTD
Fan Yadong,Zhan Qinghua,Cai Li1,Qi Wei4
1. Wuhan University Wuhan 430072 China;
2. Technological School of Transmission and Transformation, Northeast Dianli University Jilin 132012 China;
3. Guangdong Grid Corporation Foshan 528000 China;
4. State Grid Ningbo Yinzhou Power Supply Company Ningbo 315100 China
全文: PDF (348 KB)  
输出: BibTeX | EndNote (RIS)      
摘要 传统的经验公式法估算架空线雷电感应过电压误差大且存在影响因素考虑不全面的局限性.对此提出一种基于多阶时域有限差分的数值计算新方法.该方法采用一阶时域有限差分(FDTD)法计算回击电流所引发的雷电电磁脉冲(LEMP);采用二阶时域有限差分(FDTD 2nd)法求解耦合电路的Agrawal微分方程,计算不同工况时LEMP激励下架空导线的感应过电压.该方法采用多阶FDTD技术实现了高稳定性和高精度的数值计算,与火箭引雷试验对比证明计算准确性.仿真计算表明:回击电流幅值对感应电压幅值影响明显,对波形影响小;回击电流波头陡度对感应电压波形影响较大,对幅值影响较弱;多导线之间有“屏蔽效应”,该效应受导线排布方式影响明显.
服务
把本文推荐给朋友
加入我的书架
加入引用管理器
E-mail Alert
RSS
作者相关文章
关键词 时域有限差分二阶时域有限差分雷电电磁脉冲雷电感应过电压    
Abstract:Traditional empirical formula methods exist great errors and limitations of factors considering in estimating the overhead line lightning induced over-voltage. Therefore, a new numerical method based on multiple order finite difference time domain(FDTD) was proposed in this paper. The lightning electromagnetic pulse(LEMP) near the return channel is obtained by using the FDTD method; The Agrawal differential equations of coupling circuit are solved by the Second-order FDTD method. Based on the two steps, the over-voltage and over-current of overhead line excited by LEMP in different conditions can be obtained. This method achieves high stability and high precision numerical calculation by using multiple order FDTD technology, and compered with observed data from rocket triggered lightning flash, it was verified to be correct. The simulation results showed that: the effect of return stroke current amplitude on the induction voltage amplitude is significantly, and little on waveform; The effect of return stroke current wave gradient on the induction voltage waveform is obviously, and little on amplitude; There is "shielding effect" between multi-conductor, and the “effect” affected by conductor arrangement obviously.
Key wordsFinite difference time domain (FDTD)    2nd FDTD    lightning electromagnetic pulse (LEMP)    lightning induced over-voltage   
收稿日期: 2014-09-10      出版日期: 2015-09-14
PACS: TM86  
基金资助:国家自然科学基金(51207116), 南方电网公司科技项目(K-GD2014-0755)
作者简介: 樊亚东 女,1967年生,博士生导师,教授,研究方向为工程电磁场及应用.于建立(通讯作者) 男,1983年生,博士生,讲师,研究方向为电力系统过电压.
引用本文:   
1,sup 于建立 sup 1,2 sup,詹清华,王建国,1,sup 蔡力 sup 1,sup 戚为 sup 4 sup. 基于多阶FDTD雷电感应过电压计算新方法[J]. 电工技术学报, 2015, 30(12): 336-343. Fan Yadong,Zhan Qinghua,Cai Li,Qi Wei. New Method of Lightning Induced Over-voltage Based on Multiple Order FDTD. Transactions of China Electrotechnical Society, 2015, 30(12): 336-343.