Research on Electromagnetic Environment to Chest via Witricity
Zhao Jun1, Yang Xinsheng1, Xu Guizhi1, Li Yang2
1. Province-Ministry Joint Key Laboratory of Electromagnetic Field and Electrical Apparatus Reliability Hebei University of Technology Tianjin 300130 China 2. Tianjin Key Laboratory of Advanced Electrical Engineering and Energy Technology Tianjin Polytechnic University Tianjin 300387 China
Abstract:Magnetic coupling resonance wireless energy transmission(Wireless electricity, Witricity) is a new technology put forward by MIT in 2007.Witricity achieves middle distance wireless energy transmission through magnetic coupling resonance and it has good application prospect in the field of implantable devices. The specific absorption rate (SAR) is applied to express the magnitude of electromagnetic energy which is absorbed by local tissue of human body. In this paper a small size resonator was designed and the experiment results show that the small size Witricity system can transmit energy well. The SAR is calculated by finite difference time domain (FDTD) method through building 3D numerical model of chest and implantable coil. Results show that when transporting energy to chest implantable devices via Witricity, the maximum SAR value for 1g and 10g organism are 0.454?3W/kg and 1.072?9W/kg respectively which are both below international limit value.
赵军, 杨新生, 徐桂芝, 李阳. Witricity系统对作用于人体胸腔电磁环境的研究[J]. 电工技术学报, 2013, 28(2增): 200-203.
Zhao Jun, Yang Xinsheng, Xu Guizhi, Li Yang. Research on Electromagnetic Environment to Chest via Witricity. Transactions of China Electrotechnical Society, 2013, 28(2增): 200-203.
[1] A Kurs, A Karalis, R Moffatt, et al. Wireless power transfer via strongly coupled magnetic resonances[J]. Science, 2007, 317: 83-86. [2] Bernardi P, Cavagnaro M, Pisa S. Specific absorption rate and temperature increases in the head of a cellular-phone user[J]. Microwave Theory and Techniques, 2000, 48(7): 1118-1126. [3] Li QX, Gandhi OP. Thermal implications of the new relaxed IEEE RF safety standard for head exposures to cellular telephones at 835 and 1?900MHz[J]. Microwave Theory and Techniques, 2006, 54(7): 3146- 3154. [4] IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3?kHz to 300GHz, ANSI/IEEE, C95.1-1992, 1992. [5] F Zhang, X Liu, S A Hackworth, et al. In vitro and in vivo studies on wireless powering of medical sensors and implantable devices[C]. IEEE-NIH 2009 Life Science Systems and Applications Workshop, 2009: 9-10. [6] Fei Zhang, Steven A. Hackworth, et al. Wireless energy transfer platform for medical sensors and implantable devices[C]. 31st Annual International Confe- rence of the IEEE EMBS, 2009:1045-1048