Analysis on Lightning Current Distribution of Tall Buildings by Using Matlab and ATPDRAW
Liu Rongmei, Li Yunfeng, Wang Youhua, Wang Xun
Province-Ministry Joint Key Laboratory of Electromagnetic Field and Electrical Apparatus Reliability Hebei University of Technology Tianjin 300130 China
Abstract:The lightning current distribution characteristics of tall buildings struck by lightning was analyzed. The electrical parameters of every conductor were calculated first so as to calculate the current distribution in a tall building. The capacitance matrix of conductor branches is determined in terms of the average potential method, and the inductance matrix of conductor branches is calculated by Neuman’s formula. The electromagnetic coupling within every reinforcing steel conductor is described as parameter matrix form. According to the above algorithm, using the Matlab computer program, we can obtain the capacitance and inductance parameters of each branch, after that use ATPDRAW software for simulation. The calculation results were well consistent with the simulation results.
刘荣美, 李云峰, 汪友华, 王旭. 利用Matlab与ATPDRAW分析高层建筑物雷电流分布[J]. 电工技术学报, 2013, 28(2增): 152-156.
Liu Rongmei, Li Yunfeng, Wang Youhua, Wang Xun. Analysis on Lightning Current Distribution of Tall Buildings by Using Matlab and ATPDRAW. Transactions of China Electrotechnical Society, 2013, 28(2增): 152-156.
[1] 刘继, 王秀英, 李小玲. 大型现代电子计算机对雷电的防护及其接地系统的电磁兼容问题电力技术. 中国电力, 1985, 18(2): 46-56. Liu Ji, Wang Xiuying and Li Xiaoling. Lightning protection for large modern computer and Emc of its grounding system[J]. Electric Power, 1985, 16(5): 306-311. [2] 张小青. 高层建筑钢筋结构体雷电暂态计算模型. 中国电机工程学报, 1996, 16(5): 306-311. Zhang Xiaoqin. Calculation of lighting transients in the steel constructions of high buildings. Proceedings of the CSEE, 1996, 16(5): 306-311. [3] Corona R, Porrino A. Calculation of impulse current distributions and magnetic field in lightning protection structure: a computer and its laboratory validation[J]. IEEE Transactions on Magnetics, 1992, 28(2): 1134-1137. [4] 陈水明. 雷击建筑物时室内电子系统过电压防护研究:[博士学位论文]. 北京: 清华大学电机系, 1997. [5] 陈水明, 张小青, 吴维韩. 雷直击建筑物时电流分布的计算和试验研究. 清华大学学报(自然科学版), 1999, 39(5): 28-30. Chen Shuiming, Zhang Xiaoqin, Wu Weihan. Surge current distribution in a reinforced concrete structure during building struck by lightning. J Tsinghua Univ(Sci&Tech), 1999, 39, 5: 28-30. [6] 张小青. 建筑物内电子设备的防雷保护[M]. 北京: 电子工业出版社, 2000. [7] 陈慧, 小青, 建筑物防雷系统电气参数的计算[J]. 电力学报. 2004, 19(2): 87-90. Chen Hui, Zhang Xiaoqin. Calculation of the electrical parameters of building lightning protection systems. Journal of Electric Power, 2004, 19(2): 87-90. [8] 杨大晟, 张小青. 基于 PSCAD/EMTDC 仿真的电涌保护器暂态分析. 电工技术学报, 2010, 25(12): 79-83. Yang Dasheng, Zhang Xiaoqing. Transient analysis for surge protective device based on PSCAD/ EMTDC simulation. Transactions of China Electrotechnical Society, 2010, 25(12): 79-83. [9] 李瑞芳, 吴广宁, 曹晓斌, 等. 雷电流幅值概率计算公式. 电工技术学报, 2011, 26(4): 161-167. Li Ruifang, Wu Guangning, Cao Xiaobin, et al. Formula for probability of lightning current amplitude. Transactions of China Electrotechnical Society, 2011, 26(4): 161-167. [10] 杨琳, 吴广宁, 田晓菲. 基于 EMTP 的水平接地体冲击时-频特性分析. 电工技术学报, 2011, 26(6): 194-198. Yang Lin, Wu Guangning, Tian Xiaofei. Analysis of impulse characteristic grounding electrode in frequency and time domain based on EMTP. Transactions of China Electrotechnical Society, 2011, 26(6): 194-198.