A Neutral DC Current Blocking Device for Grounding Transformer Based on Inverse Parallel Thyristors Protection |
Wang Sheng1, 2, Lu Jiming1, Mao Chengxiong1, Wang Dan1, Mei Guihua3 |
1. Huazhong University of Science and Technology Wuhan 430074 China2. Chongqing Electric Power Company Chongqing 400080 China3. Guangdong Electric Power Research Institute Guangzhou 510600 China |
|
|
Abstract When HVDC power system operates in ground return mode, the AC grounding transformers around the electrodes always suffer from DC biases due to the DC currents through their neutral points. In this paper, a novel transformer neutral DC current blocking device (NCBD) based on inverse parallel thyristors protection is proposed and developed to solve such problem. Based on the analysis of the topology and operating principles of NCBD, the main circuit is simplified by removing the front-end rectifier circuit and the turn-off circuit of thyristor. Thus, the cost of the device can be cut down a lot. Moreover, the reliability and intelligence of NCBD are improved by its dual redundant structure, which is made up of a set of hardware integrated circuit and a set of microcomputer measure-controlling system. Simulation results, high current tests and field operation results confirm that the NCBD can resolve the demand of DC bias restraint effectively, and provide a practical based engineering solution.
|
Received: 01 April 2009
Published: 04 March 2014
|
|
|
|
|
[1] 薛向党, 郭晖, 郑云祥, 等. 在地磁感应电流作用时分析和计算电力变压器特性的一种新方法——时域和频域法[J]. 电工技术学报, 2000, 15(2): 1-5. [2] 曾连生. 直流输电接地极电流对电力变压器的影 响[J]. 高电压技术, 2005, 31(4): 57-61. [3] 李国栋, 毛承雄, 陆继明, 等. AC/DC混合输电系统分散协调控制[J]. 中国电机工程学报, 2005, 25 (19): 37-42. [4] Price P R. Geomagnetically induced current effects on transformers[J]. IEEE Transactions on Power Delivery, 2002, 17(4): 1002-1008. [5] 李晓萍, 文习山, 陈慈萱. 单相变压器直流偏磁励磁电流仿真分析[J]. 高电压技术, 2005, 31(9): 8-10. [6] 马志强. 变压器直流偏磁的原理性仿真[J]. 广东电力, 2004, 17(2): 5-9. [7] Kappenman J G, Norr S R, Sweezy G A, et al. GIC mitigation: A neutral blocking/ bypass device to prevent the flow of GIC in power systems[J]. IEEE Transactions Power Delivery, 1991, 6(3): 1271-1281. [8] Bolduc L, Granger M, Paré G, et al. Development of a DC current blocking device for transformer neutrals[J]. IEEE Transactions on Power Delivery, 2005, 20(1): 163-168. [9] 蒯狄正, 万达, 邹云. 直流输电地中电流对电网设备影响的分析与处理[J]. 电力系统自动化, 2005, 29(2): 81-82. [10] 朱艺颖, 蒋卫平, 曾昭华, 等. 抑制变压器中性点直流电流的措施研究[J]. 中国电机工程学报, 2005, 25(13): 1-7. [11] Dawalibi F P, Li Changyi, Li Yexu, et al. Mitigation of transformer saturation due to neutral HVDC current[C]. IEEE/PES Transmission and Distribution Conference and Exhibition, Dalian China, 2005: 1-6. [12] 马玉龙, 肖湘宁, 姜旭, 等. 用于抑制大型电力变压器直流偏磁的接地电阻优化配置[J]. 电网技术, 2006, 30(3): 62-65. [13] 赵杰, 黎小林, 吕金壮. 等. 抑制变压器直流偏磁的串接电阻措施[J]. 电力系统自动化, 2006, 30(12): 88-91. [14] 马志强. 消减变压器中性点直流电流抑制直流偏磁的电位补偿方法[J]. 广东电力, 2007, 20(5): 1-5. |
|
|
|