Research on Shaft Voltage and Bearing Current of Induction Motor Driven By PWM Inverter |
Bai Baodong1,2, Liu Weifeng1, Wang Yu1, Zhang Jian1 |
1.Theory and Common Technologies of Modern Electrical Equipments Key Lab Shenyang University of Technology Shenyang 110870 China 2.Special Electric Machines and High Voltage Apparatus Key Lab National Education Ministry and Shenyang University of Technology Shenyang 110870 China |
|
|
Abstract In this paper, a lumped common mode equivalent circuit model of a variable frequency motor driven by PWM inverter is proposed and the formulas of the key parameters in the equivalent circuit are presented. By researching a 3kW variable frequency motor, the simulation results and the experiment results provide the feasibility of the equivalent circuit and the parameters of the inverter fed induction motor. Base on the relationship between the common mode voltage and the generation mechanism of shaft voltage and bearing current, the impact of the carrier frequency and the motor running frequency to common mode voltage, shaft voltages and bearing currents is studied, which provides a theoretical basis for further studying of the suppression measures of bearing currents and increasing the life of a the inverter fed induction motor.
|
Received: 11 October 2013
Published: 22 May 2014
|
|
|
|
|
[1] Macdonald D, Gray W. PWM drive related bearing failures[J]. IEEE Industry Application Magazine, 1999, 5(4): 41-47. [2] 钟玉林, 赵争鸣. 改进式SHEPWM对三电平变频器系统的共模电压和轴电压的抑制作用[J]. 电工技术学报, 2009, 24(6): 48-55. Zhong Yulin, Zhao Zhengming. Common mode voltage and shaft voltage suppression on a three level NPC inverter system applying improved SHEPWM[J]. Transactions of China Electrotechnical Society, 2009, 24(6): 48-55. [3] 武玉才, 李永刚, 李和明. 基于轴电压的隐极同步发电机转子典型故障诊断[J]. 电工技术学报, 2010, 25(6): 178-184. Wu Yucai, Li Yonggang, Li Heming. Diagnosis of non-salient pole synchronous generator rotor typical faults based on shaft voltage[J]. Transactions of China Electrotechnical Society, 2010, 25(6): 178-184. [4] 朱梅生, 李志超, 卢继平. 水轮发电机轴绝缘监测方法及效果分析[J]. 电力系统保护与控制, 2010, 38(4): 126-129. Zhu Meisheng, Li Zhichao, Lu Jiping. Monitor method and effect anlaysis of shaft isolation of turbine generator[J]. Power System Protection and Control, 2010, 38(4): 126-129. [5] 张舸. 三峡电站水轮发电机组大轴绝缘监视的方案研究及工程应用[J]. 电力系统保护与控制, 2010, 38(14): 153-155. Zhang Ge. Research on the shaft insulation monitoring plan for Three Gorges Power Plant water-turbine generator setand its engineering application[J]. Power System Protection and Control, 2010, 38(14):153-155. [6] 姜彤, 周春阳, 徐永金, 等. 汽轮发电机中静止励磁轴电压的分析与抑制[J]. 电力系统保护与控制, 2012, 40(6): 142-146. Jiang Tong, Zhou Chunyang, Xu Yongjin, et al. Analysis and suppression of shaft voltage in turbonator with static excitation system[J]. Power System Protection and Control, 2012, 40(6): 142-146. [7] 黄守道, 张文娟, 高剑, 等. 准谐振控制器在抑制永磁同步电动机共模电压上的应用[J]. 电工技术学报, 2013, 28(3): 93-98. Huang Shoudao, Zhang Wenjuan, GaoJian, et al.Application of quasi-resonant controller for suppressing the common-mode voltage of permanent magnet synchronous motor[J]. Transactions of China Electrotechnical Society, 2013, 28(3): 93-98. [8] Annette Muetze, Andreas Binder.Calculation of influence of insulated bearings and insulated inner bearing seats on circulating bearing currents in machines of inverter-based drive systems[J].IEEE Transactions on Industry Applications, 2006, 42(4): 965-972. [9] 袁佳歆, 潘建兵, 饶斌斌, 等. 三相逆变器的最小共模电压PWM控制[J]. 电工技术学报, 2012, 27(8): 42-48. Yuan Jiaxin, Pan Jianbing, Rao Binbin, et al. Research on minimum common-mode voltage PWM control strategy for three-phase inverters[J]. Transactions of China Electrotechnical Society, 2012, 27(8): 42-48. [10] 贾贵玺, 周晓畅, 李华. 高压变频器输出差模滤波器设计和共模电压抑制[J]. 电工技术学报, 2011, 26(1): 161-165. Jia Guixi, Zhou Xiaochang, Li Hua. Differential mode filter design and common-mode voltage suppression at the high voltage VFD output terminals[J]. Transactions of China Electrotechnical Society, 2011, 26(1): 161-165. [11] Doyle Busse, Jay Erdman. System electrical parameters and their effects on bearing currents[J]. IEEE Transactions on Industry Applications, 1997, 33(2): 577-584. [12] Shaotang Chen, Thomas A, Lipo. Modeling of motor bearing currents in PWM inverter drives[J]. IEEE Transactions on Industry Applications, 1996, 32(6): 1365-1370. [13] Annette Muetze, William H Oh. Scaling effects of inverter induced bearing currents in AC Machines[J]. IEEE Transactions on Industry Applications, 2008, 44(3): 769-776. [14] Hirofumi Akagi, Shunsuke Tamura. A passive EMI filter for eliminating both bearing current and ground leakage current from an inverter-driven motor[J]. IEEE Transactions on Power Electronics, 2006, 21(5): 1459-1468. [15] David Hyypio. Migation of bearing electroerosion of inverter-fed motors through passive common mode voltage suppression[J]. IEEE Transactions on Industry Applications, 2005, 41(2): 576-583. [16] Umar Tabrez Shami, Hirofumi Akagi. Experimental discussions on a shaft end to end voltage appearing in an inverter driven motor[J]. IEEE Transactions on Power Electronics, 2009, 24(6): 1532-1540. |
|
|
|