Research on Train Auxiliary Power System Based on PQ Droop Control Inverter Parallel Technology |
Shen Kun1, 2, Zhang Jing1, Wang Jian2 |
1. Hunan University Changsha 410082 China 2. Zhuzhou CSR Times Electric Co., Ltd. Zhuzhou 412001 China |
|
|
Abstract In this paper, the inverter parallel technology is applied in the DC600V train auxiliary power system, which is able to improve its reliability and redundancy. The existing inverter parallel technologies and the train auxiliary power system’s characters such as multi-inverters, long-distance, high reliability and system redundancy, etc. are analyzed. A solution based on PQ (active power and reactive power) droop control inverter parallel technology is proposed for the DC600V train auxiliary power system. Then, in dqo coordinates the PQ droop control algorithm is analyzed. A MATLAB/Simulink emulation model is used for testing the auxiliary inverter parallel system as well as an experimental system with two auxiliary inverters paralleled. Simulation and experimental results verify that the power system still operate normally after load changed or power lost, which reveals that the constructed inverter parallel system can fully qualify the high reliability and system redundancy of train auxiliary power system.
|
Received: 06 January 2010
Published: 07 March 2014
|
|
|
|
|
[1] 徐林云. DC600V列车供电系统[J]. 铁道车辆, 2001, 39(3): 13-17. [2] 蒋芳政. 25T型客车供电系统新技术及运用中存在的问题[J]. 铁道车辆, 2005, 43(4): 38-43. [3] 徐德鸿. 电力电子系统建模及控制[M]. 北京: 机械工业出版社, 2005. [4] Guerrero J M, Vicuna L G, Matas J, et al. A wireless controller to enhance dynamic performance of parallel inverters in distributed generation systems[J]. IEEE Transactions Electronics, 2004, 19(5): 1205-1213. [5] Golestan S, Adabi F, Rastegar H, et al. Load sharing between parallel inverters using effective design of output impedance[C]. Australasian Universities Power Engineering Conference 2008(AUPEC’08), 2008, 199: 1-5. [6] 肖岚, 陈良亮, 李睿, 等. 基于有功和无功环流控制的DC-AC逆变器并联系统分析与实现[J]. 电工技术学报, 2005, 20(10): 7-12. [7] 林新春, 段善旭, 康勇. 基于下垂特性控制的无互联线并联UPS建模与稳定性分析[J]. 中国电机工程学报, 2004, 24(2): 33-38. [8] 姚玮, 陈敏, 陈晶晶, 等. 一种用于无互连线逆变器并联的多环控制方法[J]. 电工技术学报, 2008, 23(1): 84-89. [9] Mohamed Y A R I, El-Saadany E F. Adaptive decentralized droop controller to preserve power sharing stability of paralleled inverters in distributed generation microgrids[J]. IEEE Transactions on Power Electronics, 2008, 23(6): 2806-1816. [10] 阚加荣, 谢少军. 提高无互联线逆变器并联稳定性的一种功率运算方法[J]. 电工技术学报, 2007, 22(3): 85-90. [11] 张尧, 马皓, 雷彪, 等. 基于下垂特性控制的无互联线逆变器并联动态性能分析[J]. 中国电机工程学报, 2009, 29(3): 42-48. |
|
|
|