Abstract:Ambient temperature is an important factor influencing contact erosion of electromagnetic relay. In this paper, based on results of 1×105 cycle operations with the same load under different temperatures (room temperature: +20℃, high temperature: +125℃), the erosion of contacts and the data of tests are analyzed, and the reasons of different contact erosions and different results of tests under the two ambient temperatures are given. Then, the static and dynamic model of electromagnetic relay is built; some parameters under the influence of different contact erosions are calculated and analyzed. Finally, the different failure modes of contacts are predicted under the two ambient temperatures, and some measures of prevention and improvement are given.
翟国富, 王其亚, 程贤科, 陈志君. 常温和高温环境下电磁继电器触点侵蚀及失效模式分析[J]. 电工技术学报, 2010, 25(9): 80-86.
Zhai Guofu, Wang Qiya, Cheng Xianke, Chen Zhijun. Contact Erosion and Failure Mode Analysis of Electromagnetic RelayUnder the Circumstance of Room and High Temperatures. Transactions of China Electrotechnical Society, 2010, 25(9): 80-86.
[1] 李震彪, 张欢, 梁盼望, 等. 电源电压对继电器闭合与分断时间及触点弹跳的影响[J]. 华中科技大学学报, 2008, 36(12): 104-107. [2] 李震彪, 张欢, 郑必成, 等. 电源电压和触点材料对继电器分断时间的影响[J]. 低压电器, 2008(15): 1-3, 28. [3] 李震彪, 黄良, 吴细秀, 等. 42V汽车继电器触点电弧特性[J]. 低压电器, 2007 (15): 1-4, 43. [4] Jemaa N B, Doublet L, Morin L, et al. Break arc study for the new electrical level of 42V in automotive applications[J]. IEEE Trans. on Compon. Packag. Technol., 2002, 25(3): 420-426. [5] Sallais D, Jemma N B, Carvou E. An arc study at high DC current levels in automotive applicatioin[J]. IEEE Trans. on Compon. Packag. Technol., 2007, 30(3): 540-545. [6] Jemma N B. Short arc duration laws and distributions at low current (<1A) and voltage (14~42VDC)[J]. IEEE Trans. on Compon. Packag. Technol., 2001, 24(3): 358-362. [7] Witter G, Polevoy I. Contact erosion and material transfer for contacts in automotive relays[C]. Proceedings of the 42nd IEEE Holm Conference on Electrical Contacts, 1996, 223-228. [8] 程礼春, 李震彪, 邹积岩. 再论汽车继电器触点电侵蚀[J]. 汽车电器, 1997(4): 5-9. [9] Chen Z K, Witter G. A comparison of contact erosion for opening velocity variations for 13 volt circuits[C]. Proceedings of the 52th IEEE Holm Conference, 2006: 15-20. [10] Jemaa N B, Morin L, Benhenda S, et al. Anodic to cathodic arc transition according to break arc lengthening[J]. IEEE Trans. on Compon. Packag. Technol., 1998, 21(4): 599-603. [11] Jemaa N B, Nedelec L. Transition from the anodic arc phase to the cathodic metallic arc phase in vacuum at low DC electrical level[J]. IEEE Trans. on Compon. Packag. Technol., 2002, 25(4): 651-655.