Abstract:A real-time initiation approach of power system emergency control is proposed in this paper. In this approach, the system risk is defined and obtained by virtue of the start-up probability and the loss of system. The former can be provided by the fuzzy logic inference taking the imbalance power and the uncertainty of generator relays into account, and the latter is associated with the control cost. And then, based on the system risk, the start-up criterion is presented to decide the control time for system stability and low control cost. The approach is performed on the Hubei Grid under interconnection of North China Grid and Central China Grid. Comparing with the conventional approach, it can be validated that the proposed approach making the most of steady-state information for fast computation can avoid system instability caused by control delay or cascading blackout and ensure low control cost.
王安斯, 罗毅, 涂光瑜, 刘沛. 基于模糊风险分析的紧急控制实时启动方法[J]. 电工技术学报, 2010, 25(8): 138-144.
Wang Ansi, Luo Yi, Tu Guangyu, Liu Pei. Real-Time Initiation Approach of Emergency Control Based on Fuzzy Risk Analysis. Transactions of China Electrotechnical Society, 2010, 25(8): 138-144.
[1] 胡学浩. 智能电网——未来电网的发展态势[J]. 电网技术, 2009, 33(14): 1-5.
Hu Xuehao. Smart grid—a development trend of future power grid[J]. Power System Technology, 2009, 33(14): 1-5.
[2] 李斌, 薄志谦. 面向智能电网的保护控制系统[J]. 电力系统自动化, 2009, 33(20): 7-13.
Li Bin, Bo Zhiqian. Investigation on protection and control of smart grid[J]. Automation of Electric Power Systems, 2009, 33(20): 7-13.
[3] 吴军. 基于功率平衡保护原理的电力系统紧急控制研究[D]. 武汉: 华中科技大学, 2006.
[4] Padiyar K R, Krishna S. Online detection of loss of synchronism using energy function criterion[J]. IEEE Transactions on Power Systems, 2006, 21(1): 46-55.
[5] 张恒旭, 刘玉田. 电力系统动态频率响应时空分布特征量化描述[J]. 中国电机工程学报, 2009, 29(7): 64-70.
Zhang Hengxu, Liu Yutian. Quantitative description of space-time distribution features of dynamic frequency responses[J]. Proceedings of the CSEE, 2009, 29(7): 64-70.
[6] 李响, 张国庆, 郭志忠. 基于输电断面N-1静态安全潮流约束的联切负荷方案[J]. 电力系统自动化, 2004, 28(22): 42-45.
Li Xiang, Zhang Guoqing, Guo Zhizhong. Scheme for load-shedding based on the transmission interface N-1 static state safety power flow restriction[J]. Automation of Electric Power Systems, 2004, 28(22): 42-45.
[7] Emmanuel J Thalassinakis, Evangelos N Dialynas. A Monte-Carlo simulation method for setting the underfrequency load shedding relays and selecting the spinning reserve policy in autonomous power systems[J]. IEEE Transactions on Power Systems, 2004, 19(4): 2044-2052.
[8] 李爱民, 蔡泽祥. 基于轨迹分析的互联电网频率动态特性及低频减载的优化[J]. 电工技术学报, 2009, 24(9): 171-177.
Li Aimin, Cai Zexiang. Frequency dynamics analysis and load shedding assessment based on the dynamic simulation trajectory of interconnected power system[J]. Transactions of China Electrotechnical Society, 2009, 24(9): 171-177.
[9] 滕林, 刘万顺, 貟志皓, 等. 电力系统暂态稳定实时紧急控制的研究[J], 中国电机工程学报, 2003, 23(1): 64-69.
Teng Lin, Liu Wanshun, Yun Zhihao, et al. Study of real-time power system transient stability emergency control[J]. Proceedings of the CSEE, 2003, 23(1): 64-69.
[10] 陈德树. 大电网安全保护技术初探[J]. 电网技术, 2004, 28(9): 14-18.
Chen Deshu. Preliminary research on security protection technology of large-scale power grid[J]. Power System Technology, 2004, 28(9): 14-18.
[11] 吴军, 涂光瑜, 罗毅, 等. 基于功率平衡保护的紧急负荷控制研究[J]. 郑州大学学报(工学版), 2005, 26(2): 47-50.
Wu Jun, Tu Guangyu, Luo Yi, et al. Study on emergency load control based on power balance protection[J]. Journal of Zhengzhou University (Engineering Science), 2005, 26(2): 47-50.
[12] 吴军, 涂光瑜, 罗毅, 等. 电力系统分层紧急负荷控制[J]. 电力系统自动化, 2006, 30(20): 26-31.
Wu Jun, Tu Guangyu, Luo Yi, et al. Hierarchical load emergency control of power system[J]. Automation of Electric Power Systems, 2006, 30(20): 26-31.
[13] Miroslav Begovic, Damir Novosel, Daniel Karlsson, et al. Wide-area protection and emergency control[J]. Proceedings of the IEEE, 2005, 93(5): 876-891.
[14] 于洋. 电力系统连锁故障及相关问题的研究[D]. 杭州: 浙江大学, 2008.
[15] 王茂海, 徐正山, 谢开, 等. 基于WAMS的系统自然频率特性系数确定方法[J]. 电力系统自动化, 2007, 31(3): 15-20.
Wang Maohai, Xu Zhengshan, Xie Kai, et al. Calculation of frequency characteristic coefficients for an interconnected power system based on WAMS[J]. Automation of Electric Power Systems, 2007, 31(3): 15-20.
[16] Anderson P M, Mirheydar M. A low-order system frequency response model[J]. IEEE Transactions on Power Systems, 1990, 5(3): 720-729.
[17] Vladimir V Terzija. Adaptive underfrequency load shedding based on the magnitude of the disturbance estimation[J]. IEEE Transactions on Power Systems, 2006, 21(3): 1260-1266.