Abstract:Based on the ethylene-propylene rubber (EPR) DC feeder cable laying method to carry out the DC feeder cable insulation crack discharge test, and the discharge signal detection cable insulation fault crack damage in the feasibility is studied. Experimental results show that due to the low operating voltage, insulation good DC feeder cable can not detect discharge signal, when the cable insulation crack occurs, the buried cable would happen tracking discharge under certain conditions; spanned cable, when a smaller cable insulation damage, would happen tracking discharge similarly to buried cable's, insulation damage is large (cable core exposed) would happen pull-arc discharge. Buried cable feasibility simulation results show that the cable tracking discharge phenomenon and its insulation crack has a good correlation, and could be an early warning of the insulation crack damage, but also with the external environment-related. Prone to soil moisture-hour discharge, soil moisture is large and difficult to discharge, and would have a greater DC leakage current; only comprehensive monitoring DC leakage current and discharge signals can effectively monitoring DC feeder cable insulation crack fault.
[1] 王彦利. 地铁直流电力电缆现状、发展及选择[J]. 电气化铁道, 2002(2): 45-48. Wang Yanli. Current, develop and choice of DC power cable of metro [J]. Electrical Railway, 2002(2): 45-48. [2] 谢红, 夏金凤. 城市轨道牵引供电电缆选型分析[J].机车电传动, 2003(2): 33-35. Xie Hong, Xia Jinfeng.Analysis on the electrotype of power cables for urban mass transit traction[J]. Electric Drive for Locomotives, 2003(2): 33-35. [3] 唐崇健, 庞玉春. 轨道交通用直流牵引电缆的特性和要求[J]. 电线电缆, 2003(3): 23-26. Tang Chongjian, Pang Yuchun.Characteristics and requirements of DC traction cable for rail traffic [J]. Electric Wire & Cable, 2003(3): 23-26. [4] Bahra K S, Batty P G. Earthing and bonding of electrified railways [C]. International Conference on Developments in Mass Transit Systems, London, UK, 1998. [5] Hill R J. Electric railway traction part 3 traction power supplies[J]. Power Engineering Journal, 1994, 8(6): 275-286. [6] 方鸣. 城市轨道交通的供电制式与馈电方式[J]. 中国铁路, 2003(4): 49-53. Fang Ming. Powersupply and feeder pattern of urban mass transit[J]. China Railway, 2003(4): 49-53. [7] 沈小军, 达世鹏, 江秀臣, 等. 轨道交通直流馈电电缆故障分析及对策[J]. 高电压技术, 2007, 33(6):174-176. Shen Xiaojun, Da Shipeng, Jiang Xiuchen, et al. Faults analysis of DC feeder cable and counter measures[J].High Voltage Engineering, 2007, 33(6): 174-176. [8] 沈小军, 江秀臣, 达世鹏. 轨道交通直流电缆绝缘诊断技术研究现状及展望[J]. 电工技术学报, 2007, 22(9): 22-27. Shen Xiaojun, Jiang Xiuchen, Da Shipeng. Review and expectation of diagnosis technology on insulation of DC cable of urban transit [J]. Transactions of China Electrotechnical Society, 2007, 22(9): 22-27. [9] Shen Xiaojun, Zhang Yicheng, et al. Feasibility of living monitoring EPR DC cable based on different DC current method[C]. The 9th International Conference on Properties and Applications of Dielectric Materials, Harbin, China, 2009. [10] 杜伯学. 有机绝缘耐电痕性的评定与发展[J]. 高电压技术, 2005, 31(5): 10-13. Du Boxue. Research and development of test method on tracking resistance of polymer insulating materials[J]. High Voltage Engineering, 2005, 31(5): 10-13. [11] 杜伯学, 董典帅, 郑晓磊. 有机绝缘试样漏电痕破坏的非线性分析[J]. 电工技术学报, 2007, 22(9): 11-15. Du Boxue, Dong Dianshuai, Zheng Xiaolei. Nonlinear analysis of tracking failure of polymer insulating material [J]. Transactions of China Electrotechnical Society, 2007, 22(9):11-15.