Abstract:Compared to previous Z-source inverter topology, improved Z-source inverter has advantages such as low Z-source capacitor voltage stress and inherent inrush current limitation. This paper investigates the third harmonic injection control strategy of improved Z-source inverter. Compared to simple boost control, the third harmonic injection control can reduce the voltage stress and Z-source inductor current ripple. Theoretical analysis, simulation and experimental results are presented to demonstrate the features of the control.
[1] Peng F Z. Z-source inverter[J]. IEEE Transactions on Industry Applications, 2003, 39(2): 504-510. [2] 彭方正, 房绪鹏, 顾斌, 等. Z源变换器[J]. 电工技术学报, 2004, 19(2): 47-51. [3] Xu P, Zhang X, Zhang C W, et al. Study of Z-source inverter for grid-connected PV systems[C]. IEEE Power Electronics Specialist Conference, 2006: 3252-3256. [4] Badin R, Peng F Z, Kim H G. Grid interconnected Z-source PV system[C]. IEEE Power Electronics Specialist Conference, 2007: 2328-2333. [5] Shen M S, Joseph A, Huang Y, at al. Design and development of a 50kW Z-source inverter for fuel cell vehicles[C]. IEEE International Power Electronics and Motion Control Conference, 2006: 1-5. [6] Holland K, Peng F Z. Control strategy for fuel cell vehicle traction drive systems using the Z-source inverter[C]. IEEE Vehicle Power and Propulsion Conference, 2005: 639-644. [7] 汤雨, 谢少军. Z源逆变器及其软启动方法: 中国, 200810019291.3[P]. [8] Peng F Z, Shen M S, Qian Z M. Maximum boost control of the Z-source inverter[C]. IEEE Power Electronics Specialist Conference, 2004: 255-260. [9] Shen M S, Wang J, Peng F Z, et al. Maximum constant boost control of the Z-source inverter[C]. IEEE Industry Applications Society Annual Meeting, 2004: 142-147. [10] Shen M S, Joseph A, Wang J, et al. Comparison of traditional inverters and Z-source inverter for fuel cell vehicles[C]. IEEE Power Electronics in Transpor- tation, 2004: 125-132.