Abstract:Aiming at the problem of high energy consumption of intake pump with time- dependent static head, the law of self-adaptive head (SAH) varied by the variation of operating condition is presented, which based on the integrated analysis of the pump’s performance. The relation ship between the pump’s operational condition and its efficiency and static head is also proposed. To achieve the lowest energy consumption performance, the variable-speed control method under the constrained condition is presented, which based on the law of SAH. Operation points of maximum efficiency could be deduced exactly by SAH control method, matching variation of static head to keep operation points on the curve of maximum efficiency which is consistent with the affinity laws. The object of energy saving could be achieved by SAH control method that improves the efficiency of pump in the maximal degree. The experimental result indicates that when the same variation of speed is considered, SAH control method is better than the conventional variable-speed control method which based on the law of design head according highest efficiency of nominal speed (DHHE) in the aspect of electricity saving effect, and the electricity saved of the pump per thousand ton water by the SAH control method increases with less pump speed when the flux of different conditions meets a inequality.
何中杰, 彭建州, 汪雄海. 基于扬程自适应的机泵高效节能控制[J]. 电工技术学报, 2009, 24(11): 48-52.
He Zhongjie, Peng Jianzhou, Wang Xionghai. A High Efficient Self-Adaptive Head-Based Control for Energy Saving of a Pump. Transactions of China Electrotechnical Society, 2009, 24(11): 48-52.
[1] Xu B, Yang J, Yang H Y. Comparison of energy- saving on the speed control of the VVVF hydraulic elevator with and without the pressure accumulator[J]. Mechatronics, 2005, 15(10): 1159-1174. [2] Johnson K E, Pao L Y, Balas M J, et al. Control of variable-speed wind turbines: standard and adaptive techniques for maximizing energy capture[J]. IEEE Control Systems Magazine, 2006, 26(3): 70-81. [3] Yang H Y, Yang J, Xu B. Computational simulation and experimental research on speed control of VVVF hydraulic elevator[J]. Control Engineering Practice, 2004, 12(5): 563-568. [4] Ardanuy J F, Wilhelmi J R, Mora J J F, et al. Variable-speed hydro generation: operational aspects and control[J]. IEEE Transactions on Energy Conversion, 2006, 21(2): 569-574. [5] Xu X Y, Yu W N. Application of neuron-based adaptive control system to the operation of marine water pumps[C]. Canadian Conference on Electrical and Computer Engineering, 2005: 1355-1358. [6] 汪雄海, 石宏宇. 污水泵站系统的预测控制[J]. 电工技术学报, 2003, 18(5): 79-82, 86. [7] He Z J, Wang X H. Adaptive parameter estimation- based predictive multi-model switching control of drainage systems[C]. The Sixth World Congress on Intelligent Control and Automation, 2006: 6540- 6543. [8] 张承慧, 夏东伟, 石庆升. 计及变频器和电机损耗的全变速泵站效率优化控制[J]. 电工技术学报, 2006, 21(5): 52-57. [9] Mahdi M J, Miguel A M, Abbas A. Optimal design and operation of irrigation pumping stations[J]. Journal of Irrigation and Drainage Engineering, 2003, 129(3): 149-154. [10] 何中杰, 汪昆, 汪雄海. 污水排放系统优化控制机理及策略[J]. 电工技术学报, 2006, 21(5): 117-121. [11] Ghoneim A A. Design optimization of photovoltaic powered water pumping systems[J].Energy Conversion and Management, 2006, 47( 11-12): 1449-1463.