Application and Research of Phase Acquisition for Catenary Voltage in Electronic-Switching Passing Neutral Section System
Ran Wang1, Trillion Q.Zheng1, Ma Haoyu1, Li Xiong1, Liu Bing2
1. School of Electrical Engineering, Beijing Jiaotong University Beijing 100044 China; 2. Huawei Technologies Co., Ltd Shenzhen 518129 China; 3. China Academy of Railway Sciences Beijing 100044 China
Abstract:In the electronic-switching passing neutral section system, the dead time of no power supply for locomotive is very short. The phase of contact voltage must be measured should be accuracy and fast. In this paper, several common voltage tracking algorithm are research. Simulation results show that the zero crossing detection and phase-locked loop are not suit for the electronic-switching passing neutral section system voltage phase detector, meanwhile weighted least squares method detect the voltage phase and frequency fast and accuracy,even when there are harmonics in the voltage wave. This algorithm is used in experiment, the voltage phase detection methods, and results verify the analysis is effective in this paper.
冉旺, 郑琼林, 马浩宇, 李雄, 刘冰. 接触网电压相位检测在电子开关带载过分相系统中的应用与研究[J]. 电工技术学报, 2013, 28(1增): 231-236.
Ran Wang, Trillion Q.Zheng, Ma Haoyu, Li Xiong, Liu Bing. Application and Research of Phase Acquisition for Catenary Voltage in Electronic-Switching Passing Neutral Section System. Transactions of China Electrotechnical Society, 2013, 28(1增): 231-236.
[1] Bahrani B, Rufer A, Aeberhard, M. Catenary voltage support: adopting modern locomotives with active line-side converters[J]. IEEE Transactions on Smart Grid, 2012, 3(1): 377-387. [2] 刘冰, 冉旺, 李雄, 郑琼林. 电子开关实现带电自动过分相的研究[J]. 电力电子, 2011(3): 26-29. Liu Bing, Ran Wang, Li Xiong, et al. Research on power electronic switch used in the auto-passing neutral section with electric load[J]. Power Electronics, 2011(3): 26-29. [3] Wang Ran, Trillion Q. Zheng, Xiong Li, et al. Research on power electronic switch system used in the auto-passing neutral section with electric load[C]. International Conference on Electrical Machines and Systems, 2011: 1-4. [4] Amanci A Z, Dawson F P. Synchronization system with zero-crossing peak detection algorithm for power system applications[C]. 2011 International Power Electronics Conferrenc, 2011: 2984-2991. [5] 胡峣, 殷德奎, 王模昌. 一种迟滞比较式的FPGA过零检测电路[J]. 红外与激光工程, 2006, 35(10): 266-270. Hu Yao, Yin Dekui, Wang Mochang. Digital zero-cross detecting circuit in FPGA based on the principle of hysteresis comparator[J]. Infrared and Laser Engineering, 2006, 35(10): 266-270. [6] Chung S. K. Phase-locked loop for grid-connected three-phase power conversion systems[J]. Electric IEE Proceedings Power Applications, 2000, 147(3): 213-219. [7] Oliveira da Silva S A, Novochadlo R, Modesto R A. Single-phase PLL structure using modified p-q theory for utility connected systems[C]. Power Electronics Specialists Conference, 2008: 4706-4711. [8] Santos C H G,Silva S M,Cardoso Filho B J. A fourier-based PLL for single-phase grid connected systems[C]. Energy Conversion Congress and Exposition, 2010, 4(4): 2626-2632. [9] Sidhu T S, Sachdev M S. An iterative technique for fast and accurate measurement of power system frequency[J]. IEEE Transactions Power Delivery, 1998, 13(1): 109-115. [10] Sang-Joon Lee, Jun-Koo Kang, Seung-Ki Sul. A new phase detecting method for power conversion systems considering distorted conditions in power system[C]. 34th Industry Applications Conference, 1999, 4(4): 2167-2172. [11] 龚漫奇, 缪克英. 微积分(下)[M]. 北京:北京交通大学出版社, 2004. [12] Hong-Seok Song, Kwanghee Nam, Mutschler P. Very fast phase angle estimation algorithm for a single-phase system having sudden phase angle jumps[C]. 37th Industry Applications Conference, 2002, 3(2): 925-931.