Abstract:One of the important issues in the operation of three phase grid-connected converters is fast and precise detection of fundamental-frequency positive and negative sequence components present in three phase input voltages. A new detection algorithm based on complex least squares is proposed. This algorithm can detect amplitude and phase of grid voltage positive and negative sequence accurately and rapidly when the voltage contains high order harmonics and random noise. Because of the assumption that the frequency is known, the algorithm can’t track grid frequency variation. Kalman filter has many similarities with least squares, and it contains state equation and output equation which can estimate more grid information. Based on the above ideas, this paper proposes an improved algorithm which not only separates positive and negative sequence components, but also detects frequency variation. The simulation and experimental results verify the correctness and validity of the algorithm.
[1] Chen S Z, Cheung N C, Wong K C, et al. Integral sliding-mode direct torque control of doubly-fed induction generators under unbalanced grid voltage[J]. IEEE Transactions on Energy Conversion, 2010, 25(2): 356-368. [2] Yazdani A, Iravani R. A unified dynamic model and control for the voltage-sourced converter under unbalanced grid conditions[J]. IEEE Transactions on Power Delivery, 2006, 21(3): 1620-1629. [3] Hu Jiabing, He Yikang. Modeling and control of grid-connected voltage-sourced converters under generalized unbalanced operation conditions[J]. IEEE Transactions on Energy Conversion, 2008, 23(3): 903-913. [4] Shu Z, Guo Y, Lian J. Steady-state and dynamic study of active power filter with efficient FPGA-based control algorithm[J]. IEEE Transactions on Industrial Electronics, 2008, 55(4): 1527-1536. [5] Li Y W, Blaabjerg F, Vilathgamuwa D M, et al. Design and comparison of high performance stationary- frame controllers for DVR implementation[J]. IEEE Transactions on Power Electronics, 2007, 22(2): 602-612. [6] 赵国亮, 刘宝志, 肖湘宁, 等. 一种无时延的改进d-q变换在动态电压扰动识别中的应用[J]. 电网技术, 2004, 28(7): 53-57. [7] 张庆超, 肖玉龙. 一种改进的电压暂降检测方法[J]. 电工技术学报, 2006, 21(2): 123-126. [8] Rodriguez P, Pou J, Bergas J, et al. Decoupled double synchronous reference frame PLL for power converters control[J]. IEEE Transactions on Power Electronics, 2007, 22(2): 584-592. [9] Ghartemani M K, Reza Iravani M. A method for synchronization of power electronic converters in polluted and variable-frequency environments[J]. IEEE Transactions on Power Systems, 2004, 19(3): 1263-1270. [10] Huang C H, Lee C H, Shih K J, et al. Frequcncy estimation of distorted power system signals using a robust algorithm[J]. IEEE Transactions on Power Delivery, 2008, 23(1): 41-51.