Abstract:For single switch fault on one phase in the open-winding permanent magnet compact in-wheel(PMCW) motor drive system, a new SVPWM fault tolerant control strategy is proposed under 60°coordinate, in which the dual three-phase four-switch inverter is adopted. The voltage analytical model for fault diagnosis is applied in this strategy, and the switch fault is simulated by using bridge arm redundancy switch integrated online. Based on vector decomposition criteria, in a modulation period, one inverter is clamped at the same redundant switch status in triangle vertices, and voltage vector synthesis is performed in another inverter. Two inverters alternately run in clamp and vector synthesis. With no additional devices, the open-winding PMCW motor drive system fault-tolerant operation is achieved, and power balance between the dual inverter is also realized. Simulation and experimental verification of the fault-tolerant control strategy shows that the open-winding PMCW motor drive system can smoothly switch from fault state to fault tolerant operation.
[1] 涂小涛, 辜承林. 新型横向磁通永磁电机不同控制策略的对比实验[J]. 电工技术学报, 2012, 27(3): 62-67. Tu Xiaotao, Gu Chenglin. Experimental research on control of novel transverse-flux permanent magnet motor[J]. Transactions of China Electrotechnical Society, 2012, 27(3): 62-67. [2] Fan Ying, Luo Yong, Zhang Li, et al. Comparison of new self-decelerating permanent-magnet wheel motors with two topologies[C]. IEEE VPPC’13, 2013: 76-81. [3] 王琛琛, 李永东. 多电平变换器拓扑关系及新型拓扑[J]. 电工技术学报, 2011, 26(1): 92-99. Wang Chenchen, Li Yongdong. Multilevel Converter topologies and two novel topologies[J]. Transactions of China Electrotechnical Society, 2011, 26(1): 92-99. [4] Wu Rui, Wen Jialiang. A power loss calculation method of IGBT three-phase SPWM converter[C]. IEEE ISDEA’12, 2012: 1180-183. [5] Ramachandra R, Sekhar Srinivas S. Discontinuous decoupled PWMs for reduced current ripple in a dual two-level inverter fed open-end winding induction motor drive[J]. IEEE Transactions on Power Electronics, 2013, 28(5): 2493-2502. [6] Reddy B V, Somasekhar V T. Decoupled space-vector PWM strategies for a four-level asymmetrical open- end winding induction motor drive with waveform symmetries[J]. IEEE Transactions on Industrial Elec- tronics, 2011, 58(11): 5130-5141. [7] Figarado S, Sivakumar K. Five-level inverter scheme for an open-end winding induction machine with less number of switches[J]. IET Power Electronics, 2009, 3(4): 637-647. [8] Gopal M, Sivakumar K. A dual seven-level inverter supply for an open-end winding induction motor drive[J]. IEEE Transactions on Industrial Electronics, 2009, 56(5): 1665-1673. [9] Rajeevan P P, Sivakumar K. A seveven-level inverter topology for induction motor drive using two-level inverters and floating capacitor fed H-bridges[J]. IEEE Transactions on Power Electronics, 2011, 26(6): 1733-1740. [10] Gaeta A, Scelba G, Consoli A. Modeling and control of three-phase PMSMs under open-phase fault[J]. IEEE Transactions on Industry Applications, 2013, 49(1): 74-83. [11] An Q T, Sun L, Zhao K, Jahns T M. Scalar PWM algorithms for four-switch three-phase inverters[J]. Electronics Letters, 2010, 46(12): 900-902. [12] Errabelli R, Mutschler P. Fault tolerant voltage source inverter for permanent magnet drives[J]. IEEE Transac- tions on Power Electronics, 2011, 27(2): 500-508. [13] 朱景伟, 刁亮, 任宝珠, 等. 具有冗余特性的永磁容错电机短路故障分析与控制[J]. 电工技术学报, 2013, 28(3): 80-86. Zhu Jingwei, Diao Liang, Ren Baozhu, et al. Analysis and control of short-circuit fault in a fault-tolerant permanent magnet motor drive with redundancy[J]. Transactions of China Electrotechnical Society, 2013, 28(3): 80-86. [14] Fabien Meinguet, Ngac Ky Nguyen, Paul Sandulescu, et al. Fault-tolerant operation of an open-end winding five -phase PMSM drive with inverter faults[C]. IEEE Industrial Electronics Conference, 2013: 5191-5196. [15] Shamsi Nejad M A, Nahid Mobarakeh B, Pierfederici S, et al. Control strategies for fault tolerant PM drives using series architecture[C]. IEEE VPPC’10, 2010: 1-6.