Abstract:LCL circuit is analyzed in detail and a novel design principle about LCL is presented. Besides the filter function, the LCL circuit may work in voltage/current mode. Voltage/current mode is referenced that the output voltage/current of LCL circuit depends on the input voltage only and the change of loads has no effect on the output voltage/current when the frequency of the input voltage is the fundamental. In addition, the mode of the LCL is free to change during the operation. Therefore, the overload may be prevented with the LCL, worked at either voltage mode or current mode. Furthermore, the load short-circuit current may be controlled with LCL so that the impact on the inverter system with the short-circuit current may be minimized. In control system, the amplitude and phase of the output voltage (or current) fundamental component is also extracted in order to develop the control voltage. The design principle and the control method are verified by simulation results. And the design principle is verified by experiment results.
江渝, 王恒, 黄敏, 姜琦, 郑群英. 具有LCL电路的电压/电流模式单相逆变系统设计和控制[J]. 电工技术学报, 2013, 28(1增): 436-443.
Jiang Yu, Wang Heng, Huang Min, Jiang Qi, Zheng Qunying. Study on the Design and Control of Single-Phase Inverter System with Voltage/Current Mode Based on LCL Circuit. Transactions of China Electrotechnical Society, 2013, 28(1增): 436-443.
[1] Cha H I, Kim S S, Kang M G, et al. Real-time digital control of PWM inverter with PI compensator for uninterruptible power supply[C]. IEEE Annual Conference of the Industrial Electronics Society, 1990: 1124-1128. [2] Tomoki Yokoyama, Atsuo Kawamura. Disturbance observer based fully digital controlled PWM inverter for CVCF operation[J]. IEEE Transactions on Power Electronics, 1994, 9(5): 473-480. [3] 孔雪娟. 数字控制PWM逆变电源关键技术研究[D]. 武汉: 华中科技大学, 2005. [4] 张凯. 基于重复控制原理的CVCF-PWM逆变器波形控制技术研究[D]. 武汉: 华中科技大学, 2000. [5] Kukrer O, Komurcugil H. Deadbeat control method for single-phase UPS inverter with compensation of computation delay[J]. Proceedings of the IEEE Electronics Applications, 1999: 123-128. [6] Tai Tsangli, Chen Jianshiang. UPS inverter design using discrete-time sliding-mode control scheme[J]. IEEE Transactions on Industrial Electronics, 2002, 49(1): 67-75. [7] 周宇飞, 丘水生, 任言真. 开关变换器的时变滑模控制方法研究[J]. 电力电子技术, 2000, 34(4): 22-25. Zhou Yufei, Qiu Shuisheng, Ren Yanzhen. Study on time-varying sliding-mode control in DC/DC converter[J]. Power Electronics, 2000, 34(4): 22-25. [8] 石辛民, 郝整清. 模糊控制及其MATLAB仿真[M]. 北京: 清华大学出版社, 2008. [9] Naser M Abdel Rahim, John E Quaicoe. Analysis and design of a multiple feedback loop control strategy for single-phase voltage-source UPS inverters[J]. IEEE Transaction on Power Electronics, 1996, 11 (4): 532-541. [10] Jung Shihliang, Huang Hsiangsung, Chang Mengyueh, et al. DSP-based multiple-loop control strategy for single-phase inverters used in AC power sources[C]. IEEE Annual Power Electronics Specialists Conference, 1997: 706-712. [11] Liserre M, Dell’Aquila A, Blaabjerg F. Stability improvements of an LCL-filter based three-phase active rectifier[C]. IEEE Annual Power Electronics Specialists Conference, 2002, 3: 1195-1201. [12] 王要强, 吴凤江, 孙力, 等. 带LCL输出滤波器的并网逆变器控制策略研究[J]. 中国电机工程学报, 2011, 31(12): 34-39. Wang Yaoqiang, Wu Fengjiang, Sun Li, et al. Control strategy for grid-connected inverter with an LCL output filter[J]. Proceeding of the CSEE, 2011, 31(12): 34-39. [13] 郭小强, 邬伟扬, 顾和荣, 等. 并网逆变器LCL接口直接输出电流控制建模及稳定性分析[J]. 电工技术学报, 2010, 25(3): 102-109. [14] 江渝, 林泽科, 刘和平, 等. 变压器式可控电抗器在线状态的控制方案[J]. 重庆大学学报, 2010, 33(1): 67-72. Jiang Yu, Lin Zeke, Liu Heping et al. A novel control method for controllable reactor of transformer type[J]. Journal of Chongqing University, 2010, 33(1): 67-72.