Abstract:A triggered vacuum switch (TVS) is one of the important apparatuses in the field of pulsed power system, especially the electromagnetic launch. It has many advantages, such as wide operating voltage range, high current capability, high transfer charge, flexible trigger system, high trigger reliability, rapid dielectric recovery, long life, low noise, etc. A sample of surface-breakdown TVS with six-gap rod electrode system was fabricated in this paper. A trigger system was designed and a platform for the TVS test was set up. Experiment results show that, the sample designed has working voltage of 0.05~25kV, working current of more than 100kA in peak value and charge transfer of more than 25C. The total delay of TVS is less than 1.5μs, including the wait time of 800ns and collapse time of 700ns. At last, the working polarities are discussed, showing that the positive working mode is more reliable and advantageous.
戴玲, 周正阳, 南敬, 王延召, 林福昌. 基于六间隙棒电极结构的沿面击穿型触发真空开关的工作特点[J]. 电工技术学报, 2012, 27(10): 128-134.
Dai Ling, Zhou Zhengyang, Nan Jing, Wang Yanzhao, Lin Fuchang. Characteristics of a Surface-Breakdown Triggered Vacuum Switch with Six-Gap Rod Electrode System. Transactions of China Electrotechnical Society, 2012, 27(10): 128-134.
[1] Green A J, Christopoulos J. Plasma buildup and breakdown delay in a triggered vacuum gap[J]. IEEE Trans. Plasma Sci., 1979, PS-7(2): 111-115. [2] Shang W, Damstra G C. The main gap discharge type and mechanism of a triggered vacuum gap[C]. Proc. 17th ISDEIV, 1996: 51-55. [3] Zhengyang Z, Xiongying D, Minfu L, et al. Plasma stability in a triggered vacuum switch[J]. IEEE Transaction on Plasma Science, 2009, 37(4): 555-559. [4] Lafferty J M. Triggered vacuum gaps[J]. Proc. IEEE, 1966, 54(1): 23-32. [5] Farrall G A. Low voltage firing characteristics of a triggered vacuum gap[J]. IEEE Trans. Electron Devices, 1966, ED-13(4): 432-438. [6] Rich J A, Farrall G A, Imam I, et al. Development of a high-power vacuum interrupter[S]. General Electric Company, Schenectady, NY, EPRIEL-1895, 1981. [7] Warren T, Dickens J, Neuber A, et al. Development of improved triggered vacuum switches [C]. Proceeding of Pulsed Power Conference, 1999, 2: 1264-1267. [8] Alferov D F, Sidorov V A. Modernized triggered vacuum discharge switch with a six-gap Electrode System[J]. Instruments and Experimental Techniques, 1996, 39(3): 390-395. [9] Alferov D F, Ivanov V P, Sidorov V A. High-current vacuum switching devices for power energy storages [J]. IEEE Transaction on Magnetics, 1999, 35(1): 323-327. [10] Zhou Z, Duan X, Liao M, et al. Operational Characteristics of a field-breakdown triggered vacuum switch[J]. IEEE Trans. Magn., 2009, 45(1): 564-567.