Abstract:Proportional-resonant control with harmonic compensator of PWM rectifiers can selectively eliminate grid current harmonic. However, the eliminated current harmonic order is limited by the current loop bandwidth. To make current loop stable, delay compensation must be considered when higher order harmonics need to be eliminated. With the increasing of eliminated harmonic numbers, the controller computation expense will become heavy. The influence of grid voltage harmonic on grid current is analyzed in this paper. The grid voltage predictive method is proposed to minimize the grid current harmonic as well as to obtain high dynamic performance with proportional-resonant current controller. Experimental results show that the grid current harmonic caused by grid voltage harmonic can be eliminated effectively by the proposed method.
高吉磊, 林飞, 郑琼林. 基于网压预测的单相PWM整流器比例谐振控制[J]. 电工技术学报, 2011, 26(5): 45-45.
Gao Jilei, Lin Fei, Trillion Q Zheng. Proportional-Resonant Control of Single-Phase PWM Rectifiers Based on Grid Voltage Prediction. Transactions of China Electrotechnical Society, 2011, 26(5): 45-45.
[1] Hong Seok S, Keil R, Mutschler P, et al. Advanced control scheme for a single-phase PWM rectifier in traction applications[C]. Industry Applications Conference, 2003, 3: 1558-1565. [2] 刘志刚, 李宝昌, 汪至中. 电能反馈型电子负载的设计与实现[J]. 铁道学报, 2001, 23(3): 37-41. [3] Hung G K, Chang C C, Chen C L. Analysis and implementation of a delay-compensated deadbeat current controller for solar inverters[J]. IEE Proc. -Circuits Devices Syst., 2001, 148(5): 279-286. [4] Yu B, Chang L C. Improved predictive current controlled PWM for single-phase grid-connected voltage source inverters[C]. Power Electronics Specialists Conference, Recife, 2005: 231-236. [5] Teodorescu R, Blaabjerg F, Liserre M, et al. Proportional-resonant controllers and filters for grid-connected voltage-source converters[J]. IEE Proceedings of Electric Power Applications, 2006, 153(5): 750-762. [6] Liserre M, Teodorescu R, Blaabjerg F. Stability of photovoltaic and wind turbine grid-connected inverters for a large set of grid impedance values[J]. IEEE Transactions on Power Electronics, 2006, 21(1): 263-272. [7] Kang B J, Liaw C M. Robust hysteresis current- controlled PWM scheme with fixed switching frequency[J]. IEE Proceedings of Electric Power Applications, 2001, 148(6): 503-512. [8] 李春龙, 沈颂华, 卢家林, 等. 基于状态观测器的PWM整流器电流环无差拍控制技术[J]. 电工技术学报, 2006, 21(12): 84-89. [9] Lezana P, Silva C A, Rodríguez J, et al. Zero-steady- state-error input-current controller for regenerative multilevel converters based on single-phase cells[J]. IEEE Transactions on Industrial Electronics, 2007, 54(2): 733-740. [10] Zhou K L, Wang D W. Digital repetitive controlled three-phase PWM rectifier[J]. IEEE Transactions on Power Electronics, 2003, 18(1): 309-316. [11] Wu X H, Panda S K, Xu J X. DC link voltage and supply-side current harmonics minimization of three phase PWM boost rectifiers using frequency domain based repetitive current controllers[J]. IEEE Trans- actions on Power Electronics, 2008, 23(4): 1987- 1997. [12] Yepes A G, Freijedo F D, López Ó, et al. High-performance digital resonant controllers imple- mented with two integrators[J]. IEEE Transactions on Power Electronics, 2011, 26(2): 563-576. [13] 邹仁. 四象限变流器瞬态电流控制的仿真研究[J]. 机车电传动, 2003(6): 17-20. [14] 张凯. 基于重复控制原理的CVCF-PWM逆变器波形控制技术研究[D]. 武汉: 华中理工大学, 2000. [15] 耿攀, 戴珂, 魏学良, 等. 三相并联型有源电力滤波器电流重复控制[J]. 电工技术学报, 2007, 22(2): 127-131. [16] Ye Y Q, Zhou K L, Zhang B, et al. High-performance repetitive control of PWM DC-AC converters with real-time phase-lead FIR filter[J]. IEEE Transactions on Circuits and Systems, 2006, 53(8): 768-772. [17] Zhang B, Wang D W, Zhou K L, et al. Linear phase lead compensation repetitive control of a CVCF PWM inverter[J]. IEEE Transactions on Industrial Electronics, 2008, 55(4): 1595-1602. [18] Costa Castelló R, Griñó R, Fossas E. Odd-harmonic digital repetitive control of a single-phase current active filter[J]. IEEE Transactions on Power Electronics, 2004, 19(4): 1060-1068.