Abstract:A new type AC/DC/AC high frequency converter is presented, which is based on the series resonance and suitable for the contactless power transfer (CPT) system. This converter can avoid shortcomings of traditional AC/DC/AC converter which include DC filter and DC adjuster, and it can simplify the control of the sine voltage output of second circuit. This paper introduces the topology and operating principle of the converter. Different running modes are analyzed with accurate modeling. Simulation and experiments verify the analysis results.
王智慧, 孙跃, 苏玉刚, 戴欣, 唐春森. 适用于非接触电能传输系统的新型AC/DC/AC变换器[J]. 电工技术学报, 2010, 25(1): 84-89.
Wang Zhihui, Sun Yue, Su Yugang, Dai Xin, Tang Chunsen. A New Type AC/DC/AC Converter for Contactless Power Transfer System. Transactions of China Electrotechnical Society, 2010, 25(1): 84-89.
[1] Eun-Soo K, Sung In K, Kwang Ho Y, et al. A contactless power supply for photovoltaic power generation system[C]. Applied Power Electronics Conference and Exposition, Twenty-Third Annual IEEE, 2008: 1910-1913.
[2] Sergeant P, Van B A. Inductive coupler for contactless power transmission[J]. Electric Power Applications, IET, 2008, 2(1): 1-7.
[3] 戴欣, 孙跃. 单轨行车新型供电方式及相关技术分析[J]. 重庆大学学报(自然科学版), 2003, 26(1):50-53.
[4] Hu A P, Chen Z J, Hussmann S, et al. A dynamically on-off controlled resonant converter designed for coal mining battery charging applications[J]. Power System Technology, 2002(2): 1039-1044.
[5] Boys J T, Elliott G A, Covic G A. An appropriate magnetic coupling co-efficient for the design and comparison of ICPT pickups[J]. IEEE Transactions on Power Electronics, 2007, 22(1): 333-335.
[6] 孙跃, 王智慧. 非接触电能传输系统的频率稳定性研究[J]. 电工技术学报, 2005, 20(11):56-59.
[7] Calleja H, Ordofiez R. Control circuit for an induction heating inverter with active PFC[C]. PESC’98 Record, 29th Annual IEEE, 1998: 485-490.
[8] Calleja H, Ordonez R. Improved induction-heating inverter with power factor correction[C]. PESC’99 Record, 30th Annual IEEE, 1999: 1132-1137.
[9] Uchihori Y, Kawamura Y, Tokiwa M, et al. New induction heated fluid energy conversion processing appliance incorporating auto-tuning PID control- based PWM resonant IGBT inverter with sensorless power factor correction[C]. PESC '95 Record, 26th Annual IEEE, 1995: 1191-1197.