Insulation Characteristics and Influencing Factors of Transformer Oil Containing Cellulose Particles under Low-Frequency Voltage |
Liu Yunpeng1,2, Zhao Jiaying1, Liu Hechen1,2, Zhao Tao1, Yin Ziao1 |
1. Hebei Key Laboratory of Green and Efficient New Electrical Materials and Equipment North China Electric Power University Baoding 071003 China; 2. State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources North China Electric Power University Beijing 102206 China |
|
|
Abstract Low-frequency transformer is the key equipment in low-frequency transmission systems, and its insulation characteristics under low-frequency voltage are important for its design and operation. In this paper conducted transformer oil breakdown tests at different cellulose particle size (low, medium, and high) levels to study the insulation characteristics of transformer oil containing cellulose particles under low-frequency voltage. The test frequency was selected as 20, 30, 40, and 50 Hz, and the content of cellulose particles in oil samples was selected as low, medium, and high particle size levels. According to the IEC 60156 standard, the pressure was increased step by step at a constant rate of 2 kV/s to the oil sample breakdown, and the oil sample in the oil cup was replaced every 6 times after the breakdown. In order to ensure the consistency of the test, 30 times of breakdown tests were repeated respectively at each frequency and particle size level, and the effective value of breakdown voltage was recorded. The Weibull distribution method was used to analyze the test results. The test results show that at the low particle size level, the breakdown voltage at 50 Hz is taken as the reference, and the breakdown voltage at 20, 30, and 40 Hz is increased by 12.25%, 25.62%, and 39.14%, respectively. At the high particle level, the breakdown voltage increases by 21.45%, 83.69%, and 97.30% at 20, 30, and 40 Hz, respectively. At the same time, the accumulation process of cellulose particles at the electrode was observed by experiments, and the movement of cellulose particles in transformer oil at different frequencies was analyzed by multi-physical field simulation. In this paper, an observation test was carried out on the motion characteristics of cellulose particles for transformer oil with high particle size levels. 18 kV was selected as the test voltage and carried out at room temperature. The distribution state of cellulose particles between electrodes was observed with a camera. Finally, COMSOL finite element software “AC-DC module” and “Particle tracking module” are used to simulate the motion trajectory of particles in the slightly uneven field of transformer oil under four frequencies. The results show that the agglomeration rate of particles towards the electrode at a low frequency 20 Hz was significantly lower than that at a power frequency 50 Hz. More impurities would accumulate near the electrode at 50 Hz, and the bridge of impurities was broader than that at 20 Hz. The results show that the AC voltage frequency significantly affects the bridge formation characteristics and breakdown voltage of cellulose particles in transformer oil. When the transformer is running, the breakdown voltage of transformer oil increases with the decrease of AC voltage frequency, and the higher the granularity level, the more significant the difference in breakdown voltage between frequencies. The frequency of AC voltage will affect the moving speed of impurity particles and the formation process of impurity Bridges in transformer oil. The research results of this paper provide essential data support for the design, operation, and maintenance of low-frequency transformers.
|
Received: 01 November 2022
|
|
|
|
|
[1] 林进钿, 倪晓军, 裘鹏. 柔性低频交流输电技术研究综述[J]. 浙江电力, 2021, 40(10): 42-50. Lin Jintian, Ni Xiaojun, Qiu Peng.Review of flexible low-frequency AC transmission technology[J]. Zhejiang Electric Power, 2021, 40(10): 42-50. [2] 王邦彦, 王秀丽, 王碧阳, 等. 海上风电分频送出系统可靠性评估模型及方法[J]. 电网技术, 2022, 46(8): 2899-2909. Wang Bangyan, Wang Xiuli, Wang Biyang, et al.Reliability evaluation model and method of offshore wind power fractional frequency delivery system[J]. Power System Technology, 2022, 46(8): 2899-2909. [3] Chen Hao, Johnson M H, Aliprantis D C.Low- frequency AC transmission for offshore wind power[J]. IEEE Transactions on Power Delivery, 2013, 28(4): 2236-2244. [4] 张永泽, 唐炬, 潘成, 等. 油流速度对含气泡变压器油击穿特性的影响[J]. 电工技术学报, 2022, 37(2): 479-487. Zhang Yongze, Tang Ju, Pan Cheng, et al.Impact of velocity on breakdown characteristics of transformer oil containing bubbles[J]. Transactions of China Electrotechnical Society, 2022, 37(2): 479-487. [5] 董明, 杨凯歌, 马馨逸, 等. 纳米改性变压器油中载流子输运特性分析[J]. 电工技术学报, 2020, 35(21): 4597-4608. Dong Ming, Yang Kaige, Ma Xinyi, et al.Analysis of charge-carrier transport characteristics of transformer oil-based nanofluids[J]. Transactions of China Elec- trotechnical Society, 2020, 35(21): 4597-4608. [6] 李博, 程涣超, 孙倩, 等. 交直流电压分量对变压器油中典型模型击穿特性影响[J]. 电工技术学报, 2011, 26(2): 34-38. Li Bo, Cheng Huanchao, Sun Qian, et al.Influences of AC and DC voltage component on typical insulation model breakdown characteristics in trans- former oil[J]. Transactions of China Electrotechnical Society, 2011, 26(2): 34-38. [7] 王有元, 李熙, 李原龙, 等. 交直流复合电压下铜颗粒在油中的分布及对绝缘油击穿特性的影响[J]. 电工技术学报, 2018, 33(23): 5581-5590. Wang Youyuan, Li Xi, Li Yuanlong, et al.Distri- bution of copper particle in insulating oil and its influence on breakdown strength of insulating oil under combined AC and DC voltage[J]. Transactions of China Electrotechnical Society, 2018, 33(23): 5581-5590. [8] 郝建, 但敏, 廖瑞金, 等. 颗粒属性对矿物绝缘油直流击穿特性的影响差异及原因分析[J]. 电工技术学报, 2019, 34(24): 5270-5281. Hao Jian, Dan Min, Liao Ruijin, et al.Influence of particle properties on DC breakdown characteristics of mineral oil and its difference reason analysis[J]. Transactions of China Electrotechnical Society, 2019, 34(24): 5270-5281. [9] Lu W, Liu Q.Effect of cellulose particles on impulse breakdown in ester transformer liquids in uniform electric fields[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2015, 22(5): 2554-2564. [10] 贺博, 王鹏, 吴锴, 等. 多物理场中染污绝缘油内杂质相动力学行为研究综述[J]. 电工技术学报, 2022, 37(1): 266-282. He Bo, Wang Peng, Wu Kai, et al.Reviews on impurity phase dynamics in contaminated insulating oil under multi-physical field conditions[J]. Transa- ctions of China Electrotechnical Society, 2022, 37(1): 266-282. [11] 陈彬, 韩超, 刘阁. 颗粒污染物对变压器油击穿电压的影响[J]. 高电压技术, 2018, 44(12): 3903-3909. Chen Bin, Han Chao, Liu Ge.Effect of particulate contamination on breakdown voltage of transformer oil[J]. High Voltage Engineering, 2018, 44(12): 3903-3909. [12] 贾江波, 张乔根, 师晓岩, 等. 交流电压下绝缘子附近导电微粒运动特性[J]. 电工技术学报, 2008, 23(5): 7-11. Jia Jiangbo, Zhang Qiaogen, Shi Xiaoyan, et al.Motion of conducting particle near PTFE spacer under AC voltage[J]. Transactions of China Electrotechnical Society, 2008, 23(5): 7-11. [13] Zhang Jing, Li Jian, Huang Dali, et al.Influence of nonmetallic particles on the breakdown strength of vegetable insulating oil[C]//2015 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP), Ann Arbor, MI, 2015: 609-612. [14] Hao Jian, Dan Min, Liao Ruijin, et al.Effect of moisture on particles accumulation and oil breakdown characteristics in mineral oil and natural ester under non-uniform DC electrical field[J]. IEEE Access, 2019, 7: 101785-101794. [15] 杜岳凡, 李成榕, 吕玉珍, 等. TiO2纳米颗粒对矿物及植物纳米变压器油中电荷输运特性的影响[J]. 高电压技术, 2013, 39(8): 1941-1946. Du Yuefan, Li Chengrong, Lü Yuzhen, et al.Effect of TiO2 nanoparticles on charge transport characteristics in mineral and plant nanotransformer oil[J]. High Voltage Technology, 2013, 39(8): 1941-1946. [16] 姚志松, 姚磊. 变压器油的选择、使用和处理[M]. 北京: 机械工业出版社, 2007. [17] Mahmud S, Golosnoy I O, Chen G, et al.Numerical simulations of bridging phenomena in contaminated transformer oil[C]//Annual Report Conference on Electrical Insulation and Dielectric Phenomena, Montreal, QC, Canada, 2012: 383-386. [18] Mahmud S, Golosnoy I O, Chen G, et al.Effect of Kraft paper barriers on bridging in contaminated transformer oil[C]//2014 IEEE Conference on Elec- trical Insulation and Dielectric Phenomena (CEIDP), Des Moines, IA, USA, 2014: 110-113. [19] 梁晨, 伍衡, 李原龙, 等. 油中碳颗粒对交直流复合电压下绝缘油击穿特性的影响[J]. 绝缘材料, 2018, 51(4): 21-27. Liang Chen, Wu Heng, Li Yuanlong, et al.Effect of carbon particles on breakdown strength of insulating oil under AC/DC composite voltage[J]. Insulating Materials, 2018, 51(4): 21-27. [20] 郝建, 秦威, 但敏, 等. 交流和直流电压下纤维和金属颗粒对天然酯击穿特性的影响差异研究[J]. 高电压技术, 2020, 46(1): 195-204. Hao Jian, Qin Wei, Dan Min, et al.Influence difference of fiber and metal particles on breakdown characteristics of natural ester under AC and DC voltages[J]. High Voltage Engineering, 2020, 46(1): 195-204. [21] 赵涛, 律方成, 刘云鹏, 等. 纤维素颗粒物对变压器油冲击击穿特性影响的试验研究[J]. 电工技术学报, 2018, 33(7): 1626-1633. Zhao Tao, Lü Fangcheng, Liu Yunpeng, et al.Experimental study on effect of cellulose particulate matter on impact and breakdown characteristics of transformer oil[J]. Transactions of the China Electro- technical Society, 2018, 33(7): 1626-1633. [22] Kurgan E.Comparison of different force calculation methods in DC dielectrophoresis[J]. Electrotech. Rev, 2012, 88: 11-14. [23] 李原, 张乔根, 赵毅. 直流电压下纤维小桥对油纸复合绝缘局部放电特性的影响[J]. 高电压技术, 2018, 44(11): 3611-3618. Li Yuan, Zhang Qiaogen, Zhao Yi.Effect of cellulose bridge on characteristics of partial discharge in oil- paper insulation under DC voltage[J]. High Voltage Engineering, 2018, 44(11): 3611-3618. [24] 张晓星, 张锦斌, 唐炬, 等. 镍掺杂碳纳米管传感器检测变压器油中溶解气体的气敏性[J]. 中国电机工程学报, 2011, 31(4): 119-124. Zhang Xiaoxing, Zhang Jinbin, Tang Ju, et al.Ni- doped carbon nanotube sensor for detecting dissolved gases in transformer oil[J]. Proceedings of the CSEE, 2011, 31(4): 119-124. [25] Mahmud S, Chen G, Golosnoy I O, et al.Experimental studies of influence of DC and AC electric fields on bridging in contaminated transformer oil[J]. IEEE Transactions on Dielectrics & Electrical Insulation, 2015, 22(1): 152-160 [26] Zhao Tao, Liu Yunpeng, Lü Fangcheng, et al.Cellu- lose particle dynamics simulation in transformer oil under non-uniform electric field[C]//2017 IEEE 19th International Conference on Dielectric Liquids (ICDL), Manchester, UK, 2017: 1-4. [27] 蔡文莱, 黄亚军, 刘伟阳, 等. 柔性微粒介电泳分离过程的多尺度模拟[J]. 力学学报, 2019, 51(2): 405-414. Cai Wenlai, Huang Yajun, Liu Weiyang, et al.Multi- scale simulation of the dielectrophoresis separation process of flexible microparticle[J]. Chinese Journal of Theoretical and Applied Mechanics, 2019, 51(2): 405-414. [28] Morgan H, Green N G.Dielectrophoretic manipu- lation of rod-shaped viral particles[J]. Journal of Electrostatics, 1997, 42(3): 279-293. [29] 陈巧莹. 基于介电泳原理的微尺度颗粒行为分析及微传感器研究[D]. 成都: 西南交通大学, 2019. [30] 孙治谦, 周衍涛, 李宁, 等. 非均匀正弦交流电场液滴介电泳迁移规律研究[J]. 高校化学工程学报, 2021, 35(3): 464-470. Sun Zhiqian, Zhou Yantao, Li Ning, et al.Investi- gation of droplet dielectrophoresis movement under non-uniform AC electric fields[J]. Journal of Chemi- cal Engineering of Chinese Universities, 2021, 35(3): 464-470. [31] Mahmud S, Chen G, Golosnoy I O, et al.Experi- mental studies of influence of different electrodes on bridging in contaminated transformer oil[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2015, 22(5): 2433-2441. [32] Li Yuan, Zhang Qiaogen, Li Jinzhong, et al.Study on micro bridge impurities in oil-paper insulation at DC voltage: their generation, growth and interaction with partial discharge[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2016, 23(4): 2213-2222. [33] Li Yuan, Zhang Qiaogen, Ding Yuqin, et al.Effect of cellulose impurities on partial discharges in oil- pressboard insulation under DC voltage[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2017, 24(4): 2271-2273. |
|
|
|