Adaptive Linear Active Disturbance Rejection Control Method and Ripple Suppression Compensation Strategy for Three-Phase Isolated AC-DC-DC Power Supply |
Meng Jianhui1, Wu Xiaolong1, Zhang Zili2, Ye Tairan1, Yu Jingsen1, Gu Likang1 |
1. State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources North China Electric Power University Baoding 071003 China; 2. State Grid Handan Electric Power Supply Company Handan 056035 China |
|
|
Abstract Three-phase isolated AC-DC-DC power supplies are widely used in industry due to their advantages of high power density and electrical isolation. However, in some particular application scenarios with frequent load switching, such as electrophoresis and electroplating, since the core isolated DC-DC converter is a typical nonlinear system, the power supply based on the traditional PI linear control method has slow output voltage response speed and large ripple, and cannot cope with the voltage sag or swell caused by the sudden change of load, especially for voltage-sensitive DC loads. Therefore, improving the output voltage response speed and reducing the ripple from the control level is urgent. This paper analyzes the relationship between the key bandwidth parameters and output quantities in the linear active disturbance rejection control based on traditional linear active disturbance rejection control research. An Adaptive linear active disturbance rejection control (A-LADRC) method with adaptive adjustment of the controller bandwidth parameters is proposed. The proposed control method can collect the current value supplied to the load terminal by the system in real-time, and select it according to the designed controller bandwidth. According to the rules, the bandwidth parameters of the controller are adjusted online to realize the rapid adjustment of the output voltage under the sudden load change. In view of the increase of the output voltage ripple caused by the voltage six-pulse component in the uncontrolled rectification of the front stage of the AC-DC-DC research system, the six-fold frequency pulsation of the power supply is analyzed by formula. Then a duty cycle compensation control (DCCC) strategy is designed to adaptively adjust the duty cycle compensation of the converter according to the feedback value of the system output voltage. This method can provide the compensation amount of the converter duty cycle according to the detected output voltage deviation, assisting A-LADRC in fine-tuning the system output voltage to reduce voltage ripple. Finally, the proposed method is verified by a 400 V/50 A experimental prototype. The experiments compare and verify the traditional PI control, linear active disturbance rejection control, and the A-LADRC with the duty cycle compensation control proposed in this paper. The experimental results show that among the output voltages at system startup under the same control parameters, the proposed A-LADRC control takes the least time to reach stability, and the time is 0.03 s, which is about 80 % less than that of the PI control, and overshoot is significantly reduced. In the sudden load simulation experiment, the output voltage dropped from 200 V to 30 V under PI control. Under the control method proposed in this paper, the output voltage only suddenly dropped to 194 V, and the sag amplitude was reduced by about 96 % compared with PI control. During PI control, the output voltage ripple fluctuation amplitude is 3.2 V. After using the control method proposed in this paper, the voltage ripple fluctuation amplitude is about 0.31 V, about 90 % lower than that of PI control. The results show that the proposed method can effectively improve the response speed of the system output voltage, reduce the voltage ripple, and solve the problems caused by the AC-DC-DC power supply in particular application scenarios from the control level.
|
Received: 23 May 2022
|
|
|
|
|
[1] Lee S, Park J W.A new control for synchronous rectifier of phase-shifted full-bridge converter to improve efficiency in light-load condition[J]. IEEE Transactions on Industry Applications, 2021, 57(4): 3822-3831. [2] 杨超, 许海平, 袁志宝, 等. 双PWM控制下三电平半桥隔离型双向DC-DC变换器的全局最小峰值电流研究[J]. 电工技术学报, 2020, 35(8): 1679-1689. Yang Chao, Xu Haiping, Yuan Zhibao, et al.Global minimum peak current control of the three level isolated half-bridge bi-directional DC-DC converters with PWM-phase-shifting control[J]. Transactions of China Electrotechnical Society, 2020, 35(8): 1679-1689. [3] 张辉, 梁誉馨, 孙凯, 等. 直流微电网中多端口隔离型DC-DC变换器的改进虚拟电容控制策略[J]. 电工技术学报, 2021, 36(2): 292-304. Zhang Hui, Liang Yuxin, Sun Kai, et al.Improved virtual capacitor control strategy of multi-port isolated DC-DC converter in DC microgrid[J]. Transactions of China Electrotechnical Society, 2021, 36(2): 292-304. [4] 叶海涵, 陈武. 隔离型链式储能系统优化设计研究[J]. 电力工程技术, 2020, 39(4): 171-179. Ye Haihan, Chen Wu.Optimization design of isolated cascaded energy storage system[J]. Electric Power Engineering Technology, 2020, 39(4): 171-179. [5] 高明, 王大志, 李召. 移相全桥变换器的PWM全阶鲁棒滑模控制[J]. 电工技术学报, 2018, 33(10): 2293-2302. Gao Ming, Wang Dazhi, Li Zhao.A PWM full order robustness sliding mode control for phase-shifted full-bridge converter[J]. Transactions of China Elec- trotechnical Society, 2018, 33(10): 2293-2302. [6] Leso M, Zilkova J, Girovsky P.Development of a simple fuzzy logic controller for DC-DC con- verter[C]//2018 IEEE 18th International Power Elec- tronics and Motion Control Conference (PEMC), Budapest, Hungary, 2018: 86-93. [7] 年珩, 叶余桦. 三端口隔离双向DC-DC变换器模型预测控制技术[J]. 电工技术学报, 2020, 35(16): 3478-3488. Nian Heng, Ye Yuhua.Model predictive control of three-port isolated bidirectional DC-DC converter[J]. Transactions of China Electrotechnical Society, 2020, 35(16): 3478-3488. [8] Liu Hemiao, Zhao Yulian, Al Shurafa M, et al.A novel PID control strategy based on PSO-BP neural network for phase- shifted full-bridge current-doubler synchronous rectifying converter[C]//2021 IEEE 4th Advanced Information Management, Communicates, Electronic and Automation Control Conference (IMCEC), Chongqing, China, 2021: 1241-1245. [9] 高志强. 自抗扰控制思想探究[J]. 控制理论与应用, 2013, 30(12): 1498-1510. Gao Zhiqiang.On the foundation of active dis- turbance rejection control[J]. Control Theory & Applications, 2013, 30(12): 1498-1510. [10] 李志华, 曾江, 黄骏翅, 等. 基于线性自抗扰控制的微网逆变器时-频电压控制策略[J]. 电力系统自动化, 2020, 44(10): 145-154. Li Zhihua, Zeng Jiang, Huang Junchi, et al.Time- frequency voltage control strategy of microgrid inverter based on linear active disturbance rejection control[J]. Automation of Electric Power Systems, 2020, 44(10): 145-154. [11] Gao Zhiqiang.Scaling and bandwidth parameteri- zation based controller tuning[C]//Proceedings of the American Control Conference, Denver, CO, 2003: 4989-4996. [12] Zhou Xuesong, Zhong Weibao, Ma Youjie, et al.Control strategy research of D-STATCOM using active disturbance rejection control based on total disturbance error compensation[J]. IEEE Access, 2021, 9: 50138-50150. [13] 许文波, 魏泽宇, 孔伟, 等. PMSM伺服系统线性自抗扰控制器的参数整定[J]. 控制理论与应用, 2022, 39(1): 165-178. Xu Wenbo, Wei Zeyu, Kong Wei, et al.Parameters tuning of linear active disturbance rejection controller for PMSM servo system[J]. Control Theory & Appli- cations, 2022, 39(1): 165-178. [14] Lin Ping, Wu Zhen, Liu Kunzhi, et al.A class of linear-nonlinear switching active disturbance reje- ction speed and current controllers for PMSM[J]. IEEE Transactions on Power Electronics, 2021, 36(12): 14366-14382. [15] 祝国平, 阮新波, 王学华, 等. 两级式单相逆变器二次纹波电流的抑制与动态特性的改善[J]. 中国电机工程学报, 2013, 33(12): 72-80, 188. Zhu Guoping, Ruan Xinbo, Wang Xuehua, et al.Suppression of the second harmonic current and improvement of the dynamic performance for two- stage single-phase inverters[J]. Proceedings of the CSEE, 2013, 33(12): 72-80, 188. [16] 刘斌, 贺建军, 粟梅, 等. 两级式单相逆变输入端纹波电流双反馈抑制[J]. 电工技术学报, 2013, 28(8): 187-193, 217. Liu Bin, He Jianjun, Su Mei, et al.Input ripple current active mitigating for two-stage single-phase inverter based on double channel current feedback[J]. Transactions of China Electrotechnical Society, 2013, 28(8): 187-193, 217. [17] Bandyopadhyay S, Qin Zian, Bauer P.Decoupling control of multiactive bridge converters using linear active disturbance rejection[J]. IEEE Transactions on Industrial Electronics, 2021, 68(11): 10688-10698. [18] 丁杰, 高双, 赵世伟, 等. 基于耦合电感的对称式交错并联低输入电流纹波高增益DC-DC变换器[J]. 电工技术学报, 2021, 36(7): 1507-1515. Ding Jie, Gao Shuang, Zhao Shiwei, et al.Symmetrical interleaved low input current ripple high step-up DC-DC converter based on coupled indu- ctor[J]. Transactions of China Electrotechnical Society, 2021, 36(7): 1507-1515. [19] Zhou Yihan, Chen Guipeng, Wang Fei, et al.A ZVZCS hybrid dual full-bridge converter suitable for wide input voltage range[J]. IEEE Transactions on Industrial Electronics, 2021, 68(12): 12058-12068. [20] 殷晓东, 罗登, 李祖勇, 等. 一种双向隔离DC-DC变换器二次纹波电压抑制方法[J]. 电工技术学报, 2018, 33(6): 1356-1363. Yin Xiaodong, Luo Deng, Li Zuyong, et al.A second-order ripple voltage suppression algorithm of bidirectional isolation DC-DC converter[J]. Transa- ctions of China Electrotechnical Society, 2018, 33(6): 1356-1363. [21] 马树波. kW级全砖DC-DC模块电源的设计与实现[D]. 成都: 电子科技大学, 2020. [22] 王兆安, 刘进军. 电力电子技术[M]. 5版. 北京: 机械工业出版社, 2009. [23] 杨林, 曾江, 马文杰, 等. 基于改进二阶线性自抗扰技术的微网逆变器电压控制[J]. 电力系统自动化, 2019, 43(4): 146-153. Yang Lin, Zeng Jiang, Ma Wenjie, et al.Voltage control of microgrid inverter based on improved second-order linear active disturbance rejection control[J]. Automation of Electric Power Systems, 2019, 43(4): 146-153. [24] 梁青, 王传榜, 潘金文, 等. 线性自抗扰控制参数b0辨识及参数整定规律[J]. 控制与决策, 2015, 30(9): 1691-1695. Liang Qing, Wang Chuanbang, Pan Jinwen, et al.Parameter identification of b0 and parameter tuning law in linear active disturbance rejection control[J]. Control and Decision, 2015, 30(9): 1691-1695. [25] You Jiang, Cheng Lianbin, Fu Bin, et al.Analysis and control of input-parallel output-series based combined DC/DC converter with modified connection in output filter circuit[J]. IEEE Access, 2019, 7: 58264-58276. [26] 黄先进, 赵鹃, 游小杰. 一种基于输入串联输出并联移相全桥变换器的改进交错控制方法[J]. 电工技术学报, 2020, 35(增刊1): 81-90. Huang Xianjin, Zhao Juan, You Xiaojie.An improved interlace control method based on input series output parallel phase-shifted full-bridge converter[J]. Transa- ctions of China Electrotechnical Society, 2020, 35(S1): 81-90. [27] Zaoskoufis K, Tatakis E C.Isolated ZVS-ZCS DC-DC high step-up converter with low-ripple input current[J]. IEEE Journal of Emerging and Selected Topics in Industrial Electronics, 2021, 2(4): 464-480. |
|
|
|