A Control Scheme of Current-Source PWM Rectifier Under Unbalanced Supply Conditions |
Li Heming, Zhu Xiaorong, Shi Xinchun, Peng Yonglong |
North China Electric Power University Baoding 071003 China |
|
|
Abstract Under unbalanced supply conditions, when the three-phase current-source rectifier (CSR) is used with the normal controllers, unbalanced input voltages cause abnormal even harmonics at the DC output and odd harmonics in the input currents, which worsen the performance of the CSR. In this paper, instantaneous active power balance equations at CSR AC side are deduced firstly, and then a new current-conference calculation scheme of three-phase CSR under unbalanced supply conditions is proposed, which can not only eliminate the harmonics in the DC current, but also achieve sinusoidal input current and controllable power factor. Furthermore, a novel current controller based on sliding-mode control in stationary frame is proposed, which achieves high performance current tracking. The effectiveness of the proposed unbalanced correction scheme and the current controller are validated through simulation results.
|
Received: 22 April 2009
Published: 04 March 2014
|
|
|
|
|
[1] 鲍建宇. 电流型多电平拓扑及其控制策略的研究[D]. 杭州: 浙江大学, 2008. [2] 张崇巍, 张兴. PWM整流器及其控制[M]. 北京: 机械工业出版社, 2003. [3] 李亚斌, 李和明, 彭咏龙.大功率三相电流型晶闸管SVPWM整流器多桥并联技术[J]. 电工技术学报, 2007, 22(2): 84-90. [4] 朱晓荣, 李和明, 彭咏龙, 等. 基于反步法的电流型PWM整流器控制策略[J]. 电工技术学报, 2007, 22(2): 78-83. [5] Enjeti P N, Choudhury S A. A new control strategy to improve the performance of a PWM ac to dc converter under unbalanced operating conditions[J]. IEEE Transactions on Power Electronics, 1993, 8(4): 493- 500. [6] Vincenti D, Jin H. A three-phase regulated PWM rectifier with on-line feedforward input unbalance correction[J]. IEEE Transactions on Industrial Electronics, 1994, 41(5): 526-532. [7] 李玉玲, 张仲超. 电流型变流器在电网电压不平衡时的控制[J]. 电力系统自动化, 2005, 29(16): 72-75. [8] 李玉玲. 电流型PWM整流器及其控制策略的研究[D]. 杭州: 浙江大学, 2006. [9] Rioual P, Pouliquen H, Louis J. Regulation of a PWM rectifier in the unbalanced network state using a generalized model[J]. IEEE Transactions on Power Electronics, 1996, 11(3): 495-502. [10] Song H, Nam K. Dual current control scheme for PWM converter under unbalanced input voltage conditions[J]. IEEE Transactions on Industrial Electronics, 1999, 46(5): 953-959. [11] 张兴, 季建强, 张崇巍, 等. 基于内模控制的三相电压型PWM整流器不平衡控制策略研究[J]. 中国电机工程学报, 2005, 25(13): 51-56. [12] Yongsug Suh, Thomas A Lipo. Control scheme in hybrid synchronous stationary frame for PWM AC/DC converter under generalized unbalanced operating conditions[J]. IEEE Transactions on Industry Application, 2006, 42(3): 825-835. [13] 周国梁, 石新春, 付超, 等. VSC-HVDC离散模型及其不平衡控制策略[J]. 电工技术学报, 2008, 23 (12): 137-143. [14] Komatsu Y, Kawabata T. A control method of active power filter in unsymmetrical voltage system[C]. In Conference Proceedings of EPE, 1995: 904-907. [15] 朱晓荣, 彭咏龙, 李和明, 等. 电流型PWM整流器的非线性控制[J]. 中国电机工程学报, 2007, 27 (28): 96-101. [16] 赵文杰. 不确定非线性系统的变结构控制研究[D].保定: 华北电力大学, 2004. |
|
|
|