Transactions of China Electrotechnical Society  2022, Vol. 37 Issue (24): 6284-6293    DOI: 10.19595/j.cnki.1000-6753.tces.211698
Current Issue| Next Issue| Archive| Adv Search |
Improved Strategy and Experimental Research on Passive Shimming in Magnetic Resonance Imaging Magnet
Qu Hongyi1,2, Liu Xin2,3, Wang Hui1, Liu Jianhua1,2, Wang Qiuliang1,2,3
1. Institute of Electrical Engineering Chinese Academy of Science Beijing 100190 China;
2. Ganjiang Innovation Academy Chinese Academy of Sciences Ganzhou 341000 China;
3. College of Rare Earths University of Science and Technology of China Hefei 230026 China

Download: PDF (10597 KB)   HTML (1 KB) 
Export: BibTeX | EndNote (RIS)      
Abstract  Passive shimming is used to correct the inhomogeneous magnetic field of the MRI magnets. Due to the inevitable calculation errors, passive shimming must be repeated many times (iteration) to obtain a required high homogeneous static magnetic field. At present, the relevant research mainly focuses on constructing the optimization model or improving the solution algorithm. The research method is usually the numerical simulation method, ignoring the problems encountered in the shimming practice, and there is no optimization based on the shimming process. To improve the performance and efficiency of shimming, this paper presented an improved strategy for the passive shimming technology in MRI magnets: measuring the actual magnetic field of multiple representative pieces to correct the calculation; constructing a linear optimization model with the target magnetic field as a variable; adopting “Odd-Even” approach to simplify the assembly of the shim system. Finally, the experiment for the improved shimming technology was performed on a 1.5T MRI superconducting magnet. The results show that the magnetic field homogeneity that meets the imaging requirements could be obtained only through two iterations, and the design value was reached after the third iteration. Compared with the results of the method before improvement, the new shimming strategy has a significant effect.
Key wordsMagnetic resonance imaging magnet      passive shimming      corrected model      "Odd-Even" approach     
Received: 25 October 2021     
PACS: TM153  
Service
E-mail this article
Add to my bookshelf
Add to citation manager
E-mail Alert
RSS
Articles by authors
Qu Hongyi
Liu Xin
Wang Hui
Liu Jianhua
Wang Qiuliang
Cite this article:   
Qu Hongyi,Liu Xin,Wang Hui等. Improved Strategy and Experimental Research on Passive Shimming in Magnetic Resonance Imaging Magnet[J]. Transactions of China Electrotechnical Society, 2022, 37(24): 6284-6293.
URL:  
https://dgjsxb.ces-transaction.com/EN/10.19595/j.cnki.1000-6753.tces.211698     OR     https://dgjsxb.ces-transaction.com/EN/Y2022/V37/I24/6284
Copyright © Transactions of China Electrotechnical Society
Supported by: Beijing Magtech