Abstract Wide-area voltage monitoring and control system needs a fast, accurate index. This paper addresses a linearized motor voltage stability index(LMVSI) considering induction motor load characteristics. The proposed index has two advantages: ① no need of computing the network equivalents, this will improve the accuracy and computation speed of the index. ② full linearity, so this can be used to predict the load margin. NewEngland 39-bus test system and a 474-bus system are used to test the linearity degree, the computation speed of the index and the real monitoring results of the developed real-time voltage stablity monitoring system, respectively. Test results indicate that the proposed LMVSI is computationally light, fairly linear and highly accurate.
|
Received: 12 January 2009
Published: 04 March 2014
|
|
|
|
|
[1] Rehtanz C. Wide area monitoring and control for transmission capability enhancement[R]. GIGRE, Paris, France, 2006. [2] Taylor C W, Erickson D C, Martin K E, et al. WACS-Wide-Area stability and voltage control system: R&D and online demonstration[J]. Proceedings of the IEEE, 2005, 93(5): 892-906. [3] 薛禹胜, 徐伟, Dong Zhaoyang, 等. 关于广域测量系统及广域控制保护系统的评述[J]. 电力系统自动化, 2007, 31(15): 1-5. [4] Verbic G, Gubina F. A new concept of voltage- collapse protection based on local phasors[J]. IEEE Transactions on Power Delivery, 2004, 19(2): 576-581. [5] Milosevic B, Begovic M M. Voltage-stability protection and control using a wide-area network of phasor measurements[J]. IEEE Transactions on Power Systems, 2003, 18(1): 121-127. [6] Smon I, Verbic G, Gubina F. Local voltage-stability index using Tellegen’s theorem[J]. IEEE Transactions on Power Systems, 2006, 21(3): 1267-1275. [7] Smon I, Pantos M, Gubina F. An improved voltage-collapse protection algorithm based on local phasors[J]. Electric Power Systems Research, 2008, 78(3): 434-440. [8] Corsi S, Taranto G N. A real-time voltage instability identification algorithm based on local phasor measurements[J]. IEEE Transactions on Power Systems, 2008, 23(3): 1271-1279. [9] Corsi S, Pozzi M. A real-time EHV bus-bar indicator of local voltage instability[C]. IFAC Symp. Power Plants and Power Systems Control, Calgary, AB, Canada, 2006. [10] 刘道伟, 谢小荣, 穆刚, 等. 基于同步相量测量的电力系统在线电压稳定指标[J]. 中国电机工程学报, 2005, 25 (1): 13-17. [11] 黄志刚, 邬炜, 韩英铎. 基于同步相量测量的电压稳定评估算法[J]. 电力系统自动化, 2002, 26(2): 28-33. [12] 邱晓燕, 李兴源, 王建, 等. 电力系统实时等值及电压稳定性分析[J]. 电网技术, 2004, 28(7): 7-9. [13] 赵金利, 余贻鑫, Zhang Pei. 基于本地相量测量的电压失稳指标工作条件分析[J]. 电力系统自动化, 2006, 32(24): 1-4. [14] 李大虎, 曹一家. 基于同步相量测量的实时电压稳定分析方法[J]. 电力系统自动化, 2006, 30(12): 17-22. [15] 闫常友, 刘建飞, 杨奇逊. 基于当地量的电压稳定指标[J]. 电力系统自动化, 2006, 30(5): 29-32. [16] 孙华东, 周孝信, 李若梅. 计及感应电动机负荷的静态电压稳定性分析[J]. 中国电机工程学报, 2005, 25(24): 1-7. [17] 孙华东, 周孝信. 计及感应电动机负荷的电力系统在线电压稳定指标[J]. 中国电机工程学报, 2006, 26(6): 1-7. [18] 林舜江, 李欣然, 刘杨华. 考虑负荷动态模型的在线小干扰电压稳定指标[J]. 电力系统自动化, 2008, 32(9): 25-29. [19] 西安交通大学等合编. 电力系统计算[M]. 北京: 水利电力出版社, 1978. [20] He R, Ma J, Hill D J. Composite load modeling via measurement approach[J]. IEEE Transactions on Power Systems, 2006, 21(2): 663-672. [21] 曹一家, 李大虎. 基于广域测量系统的大区域电网负荷建模的研究[J]. 电力科学与技术学报, 2007, 22(2): 1-7. [22] 谢会玲, 鞠平, 陈谦, 等. 广域电力系统负荷整体建模方法[J]. 电力系统自动化, 2008, 32(1): 1-5. [23] Canizares C A. Voltage stability assessment: concepts, practices and tools[R]. IEEE/PES Power System Stability Subcommittee, Final Document, Tech. Rep., Aug. 2002. [24] 周双喜, 朱凌志, 郭锡玖, 等. 电力系统电压稳定性及其控制[M]. 北京:中国电力出版社, 2004. |
|
|