Partial Discharge Location Using Improved Phase Difference Method Considering Frequency-Dependent Characteristic of Phase Velocity |
Rao Xianjie1, Zhou Kai1, Huang Yonglu1, Wang Xianjin1, Xie Min2 |
1. School of Electrical Engineering Sichuan University Chengdu 610065 China; 2. State Grid Wuxi Power Supply Company Wuxi 214000 China |
|
|
Abstract The precision location of partial discharge (PD) in power cable is of great significance to the reliability of the urban power grid. However, the location accuracy of the traditional phase difference method is greatly influenced by noise and the frequency-dependent characteristic of phase velocity. Thus, this paper presents a new improved phase difference method to locate partial discharge source. This method takes into account the effect of phase velocity frequency change and the distribution characteristics of the PD frequency band, so it has good anti-noise capability. Firstly, the basic principle of the proposed method is introduced. To locate the PD source, the frequency range of PD signal is utilized to unwrap the phase difference. After that, the phase difference is modified by phase velocity. Then, simulations in Matlab prove the effectiveness of the proposed method. Finally, the PD source of a 250m defective power cable is located. It is shown that the proposed method has high location accuracy and can obtain better results in practical test.
|
Received: 18 May 2020
|
|
|
|
|
[1] 李长明, 伍国方, 李春阳, 等. XLPE绝缘高压直流电缆终端内缺陷对电场分布的影响[J]. 电机与控制学报, 2018, 22(12): 62-67. Li Changming, Wu Guofang, Li Chunyang, et al.Effect of the defects inside XLPE insulated HVDC cable termination on the electric field distribution[J]. Electric Machines and Control, 2018, 22(12): 62-67. [2] 乐彦杰, 汪洋, 郑新龙, 等. 交联聚乙烯与浸渍纸绝缘直流电缆接头电场分布[J]. 电机与控制学报, 2019, 23(2): 75-86. Le Yanjie, Wang Yang, Zheng Xinlong, et al.Electric field distributions in the joint of XLPE and mass impregnated HVDC cables[J]. Electric Machines and Control, 2019, 23(2): 75-86. [3] 饶显杰, 周凯, 谢敏, 等. 稳定图法在极化等效电路参数辨识中的应用[J]. 电工技术学报, 2020, 35(10): 2248-2256. Rao Xianjie, Zhou Kai, Xie Min, et al.Application of stabilization diagram method for solving polarization equivalent circuit parameters[J]. Transactions of China Electrotechnical Society, 2020, 35(10): 2248-2256. [4] 李露露, 雍静, 曾礼强, 等. 基于系统电力扰动的交叉互联电缆绝缘整体老化在线监测[J]. 电工技术学报, 2018, 33(14): 3396-3405. Li Lulu, Yong Jing, Zeng Liqiang, et al.On-line monitoring of insulation overall aging for cross-bonded cables based on system power disturbances[J]. Transactions of China Electrotechnical Society, 2018, 33(14): 3396-3405. [5] 秦雪, 钱勇, 许永鹏, 等. 基于2D-LPEWT的特征提取方法在电缆局部放电分析中的应用[J]. 电工技术学报, 2019, 34(1): 170-178. Qin Xue, Qian Yong, Xu Yongpeng, et al.Application of feature extraction method based on 2D-LPEWT in cable partial discharge analysis[J]. Transactions of China Electrotechnical Society, 2019, 34(1): 170-178. [6] 周凯, 黄永禄, 谢敏, 等. 短时奇异值分解用于局放信号混合噪声抑制[J]. 电工技术学报, 2019, 34(11): 2435-2443. Zhou Kai, Huang Yonglu, Xie Min, et al.Mixed noises suppression of partial discharge signal employing short-time singular value decom-position[J]. Transactions of China Electrotechnical Society, 2019, 34(11): 2435-2443. [7] Kreuger F H, Wezelenburg M G, Wiemer A G, et al.Partial discharge part XVIII: errors in the location of partial discharges in high voltage solid dielectric cables[J]. IEEE Electrical Insulation Magazine, 1993, 9(6): 15-25. [8] 杜言, 廖瑞金, 周湶, 等. 基于小波变换的电缆局部放电定位中时延算法研究[J]. 高压电器, 2007, 43(5): 389-393. Du Yan, Liao Ruijin, Zhou Quan, et al.Study on time delay estimation algorithm in cable partial discharge location based on wavelet transform[J]. High Voltage Apparatus, 2007, 43(5): 389-393. [9] 唐炬, 陈娇, 张晓星, 等. 用于局部放电信号定位的多样本能量相关搜索提取时间差算法[J]. 中国电机工程学报, 2009, 29(19): 125-130. Tang Ju, Chen Jiao, Zhang Xiaoxing, et al.Time difference algorithm based on energy relevant search of multi-sample applied in PD location[J]. Pro-ceedings of the CSEE, 2009, 29(19): 125-130. [10] 刘卫东, 刘尚合, 胡小锋, 等. 基于互相关信息积累的非周期微弱局部放电源探测方法[J]. 高电压技术, 2017, 43(3): 966-972. Liu Weidong, Liu Shanghe, Hu Xiaofeng, et al.Aperiodic weak partial discharge source detection based on accumulation of cross-correlation esti-mation information[J]. High Voltage Engineering, 2017, 43(3): 966-972. [11] 谢敏, 周凯, 赵世林, 等. 考虑相速度频变特性的改进互相关算法局部放电定位[J]. 电网技术, 2018, 42(5): 1661-1667. Xie Min, Zhou Kai, Zhao Shilin, et al.Research on partial discharge location using modified cross-correlation method considering frequency characteri-stic of phase velocity[J]. Power System Technology, 2018, 42(5): 1661-1667. [12] Mardiana R, Su C Q.Partial discharge location in power cables using a phase difference method[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2010, 17(6): 1738-1746. [13] 李保杰, 王庆华, 李甜, 等. 基于优化脉冲时间窗的相位差算法的电力电缆局部放电双端在线定位技术[J]. 高压电器, 2019, 55(10): 134-140. Li Baojie, Wang Qinghua, Li Tian, et al.On-line double-ended power cable PD location method based on phase difference algorithm of optimized pulse time window[J]. High Voltage Apparatus, 2019, 55(10): 134-140. [14] Lan Sheng, Hu Yuequn, Kuo Chengchien.Partial discharge location of power cables based on an improved phase difference method[J]. IEEE Transa-ctions on Dielectrics and Electrical Insulation, 2019, 26(5): 1612-1619. [15] Mohamed F P, Siew W H, Soraghan J, et al.Partial discharge location in power cables using a double ended method based on time triggering with GPS[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2013, 20(6): 2212-2221. [16] Zhou Zhiqiang, Zhang Dandan, He Junjia, et al.Local degradation diagnosis for cable insulation based on broadband impedance spectroscopy[J]. IEEE Transa-ctions on Dielectrics and Electrical Insulation, 2015, 22(4): 2097-2107. [17] 饶显杰, 周凯, 谢敏, 等. 基于频域反射法的特征时域波形恢复技术[J]. 高电压技术, 2021, 47(4): 1420-1427. Rao Xianjie, Zhou Kai, Xie Min, et al.Recovery technique of characteristic time domain waveform based on frequency domain reflection method[J]. High Voltage Engineering, 2021, 47(4): 1420-1427. [18] 张磊祺, 盛博杰, 姜伟, 等. 基于电缆传递函数和信号上升时间的电力电缆局部放电在线定位方法[J]. 高电压技术, 2015, 41(4): 1204-1213. Zhang Leiqi, Sheng Bojie, Jiang Wei, et al.On-line power cable partial discharge localisation method based on cable transfer function and detected pulse rise-time[J]. High Voltage Engineering, 2015, 41(4): 1204-1213. [19] 高树国, 刘贺晨, 范辉, 等. 考虑波速特性的小波变换模极大值法的电力电缆局部放电定位研究[J]. 电网技术, 2016, 40(7): 2244-2250. Gao Shuguo, Liu Hechen, Fan Hui, et al.PD location method of power cable based on wavelet transform modulus maxima considering wave characteristics[J]. Power System Technology, 2016, 40(7): 2244-2250. [20] 谢敏, 周凯, 黄永禄, 等. 一种基于短时奇异值分解的局部放电白噪声抑制方法[J]. 中国电机工程学报, 2019, 39(3): 915-922, 970. Xie Min, Zhou Kai, Huang Yonglu, et al.A white noise suppression method for partial discharge based on short time singular value decomposition[J]. Proceedings of the CSEE, 2019, 39(3): 915-922, 970. [21] 周凯, 谢敏, 赵世林, 等. 基于改进FastICA的局部放电在线监测窄带干扰高保真性抑制方法[J]. 电工技术学报, 2018, 33(11): 2604-2612. Zhou Kai, Xie Min, Zhao Shilin, et al.Periodic narrowband noise rejection with high fidelity of partial discharge on line monitoring based on improved FastICA algorithm[J]. Transactions of China Electrotechnical Society, 2018, 33(11): 2604-2612. [22] Papazyan R, Eriksson R.Calibration for time domain propagation constant measurements on power cables[J]. IEEE Transactions on Instrumentation and Measurement, 2003, 52(2): 415-418. [23] 周凯, 赵世林, 何珉, 等. 考虑短距离电缆中行波特性的振荡波局部放电定位方法[J]. 电网技术, 2017, 41(6): 2047-2054. Zhou Kai, Zhao Shilin, He Min, et al.An oscillating wave test method based on traveling wave characteri-stics of partial discharges for defect location in short cables[J]. Power System Technology, 2017, 41(6): 2047-2054. |
|
|
|