Transactions of China Electrotechnical Society  2021, Vol. 36 Issue (zk1): 311-320    DOI: 10.19595/j.cnki.1000-6753.tces.L90125
Current Issue| Next Issue| Archive| Adv Search |
Dynamic Characteristics Test of Insulation Pull Rod for Circuit Breaker
Wang Haoran1, Chen Yun1, Wu Zehua2, Zhang Pengfei1, Liao Wei3, Peng Zongren2
1. China Electric Power Research Institute Beijing 100192 China;
2. State Key Laboratory of Electrical Insulation and Power Equipment Xi'an Jiaotong University Xi'an 710049 China;
3. State Grid Shanghai Municipal Electric Power Company Shanghai 200122 China

Download: PDF (4045 KB)   HTML (1 KB) 
Export: BibTeX | EndNote (RIS)      
Abstract  Insulation pull rod is the main driving mechanism of the circuit breaker, which requires not only excellent electrical performance but also good mechanical properties. Exploring the dynamic characteristics and response of the insulation pull rod during operation is of great significance for material performance control and technical specification formulation. In this paper, the circuit breaker simulator was used for the first time to carry out the endurance impact test. The strain distribution and response during operation, as well as the influence of operation times on the insulation pull rod were obtained. The results show that the stress of the insulation pull rod is uneven during the operation process. The main frequency components of impact response are 0~600Hz, and the maximum strain is distributed on the contact side, where the rod bonded with the metal part. In addition, with the increase of the operation times, the first characteristic peak of the frequency response re-mains unchanged, while the high frequency component decreases. The results can provide reference and basis for the test methods, requirement and specifications of rod materials.
Key wordsGas insulated switchgear (GIS)      circuit breaker      insulation pull rod      frequency response      dynamic characteristics     
Received: 28 June 2020     
PACS: TM561  
Service
E-mail this article
Add to my bookshelf
Add to citation manager
E-mail Alert
RSS
Articles by authors
Wang Haoran
Chen Yun
Wu Zehua
Zhang Pengfei
Liao Wei
Peng Zongren
Cite this article:   
Wang Haoran,Chen Yun,Wu Zehua等. Dynamic Characteristics Test of Insulation Pull Rod for Circuit Breaker[J]. Transactions of China Electrotechnical Society, 2021, 36(zk1): 311-320.
URL:  
https://dgjsxb.ces-transaction.com/EN/10.19595/j.cnki.1000-6753.tces.L90125     OR     https://dgjsxb.ces-transaction.com/EN/Y2021/V36/Izk1/311
Copyright © Transactions of China Electrotechnical Society
Supported by: Beijing Magtech