A Quasi-Online Estimation of Metallized Film Capacitor for Fault Diagnosis Used in Electric Vehicle Drive System |
Zhang Chao1, Du Bochao1, Cui Shumei1, Zheng Wei2, Han Shouliang2 |
1. Department of Electrical Engineering Harbin Institute of Technology Harbin 150001 China; 2. Zhengzhou Yutong Bus Co. Ltd Zhengzhou 450061 China |
|
|
Abstract Metallized film capacitor is an important part of electric vehicle drive system, and the performance and safety of drive system is directly related to the health of the capacitor. To solve the problem of monitoring and diagnosis for film capacitor, a quasi-online capacitance estimation method is proposed in this paper, and this method is suited to the PMSM drive system. First, when the vehicle stops, a specific harmonic is injected into the d axis of the motor to produce a twice frequency characteristic disturbance in the DC bus. Then, the current of capacity can be reconstructed by dc bus current, IGBT on-off state and motor phase current. Finally, second order generalized integrals are used to extract the characteristic disturbance to estimate the capacity value. The experimental results demonstrate that this method can exactly estimate the capacity value to support fault diagnosis.
|
Received: 01 July 2018
Published: 05 March 2020
|
|
|
|
|
[1] 马皓, 王林国. 铝电解电容器退化分析与故障预诊断[J]. 电力系统自动化, 2005, 29(15): 68-72. Ma Hao, Wang Linguo.Degradation analysis and failure prediction of aluminum electrolytic capacitors[J]. Automation of Electric Power Systems, 2005, 29(15): 68-72. [2] 卢西伟, 刘志刚, 王磊, 等. 基于累积损伤理论的铝电解电容疲劳损伤估算方法[J]. 电工技术学报, 2011, 26(4): 13-18. Lu Xiwei, Liu Zhigang, Wang Lei, et a1. Estimate approach for fatigue damage of aluminum electrolytic capacitor based on accumulated damage theory[J]. Transactions of China Electrotechnical Society, 2011, 26(4): 13-18. [3] Amaral A, Buatti G, Ribeiro H, et al.Using DFT to obtain the equivalent circuit of aluminum electrolytic capacitors[C]//International Conference on Power Electronics and Drive Systems, Bangkok, Thailand, 2007: 434-438. [4] Amaral A M R, Cardoso A J M. A simple offline technique for evaluating the condition of aluminum electrolytic capacitors[J]. IEEE Transactions on Industry Electronics, 2009, 56(8): 3230-3237. [5] Amaral A M R, Cardoso A J M. Using newton- raphson method to estimate the condition of aluminum electrolytic capacitors[C]//International Symposium on Industrial Electronics, Vigo, Spain, 2007: 827-832. [6] Amaral A M R, Marques Cardoso A J. Simple experimental techniques to characterize capacitors in a wide range of frequencies and temperatures[J]. IEEE Transactions on Instrumentation and Measure- ment, 2010, 59(5): 1258-1267. [7] Chen Yaoming, Wu Hsuchin, Chou Mingwei, et al.Online failure prediction of the electrolytic capacitor for LC filter of switching-mode power converters[J]. IEEE Transactions on Industrial Electronics, 2008, 55(1): 400-406. [8] 唐伟杰, 姚凯, 胡文斌, 等. 一种无电流传感器的CCM Buck变换器输出电容ESR和C的在线监测方法[J]. 中国电机工程学报, 2015, 35(21): 5569-5576. Tang Weijie, Yao Kai, Hu Wenbin, et al.An online monitoring scheme of output capacitor’s ESR and C for CCM Buck converters without current sensors[J]. Proceedings of the CSEE, 2015, 35(21): 5569-5576. [9] Md Waseem Ahmad, Nikunj Agarwal, Sandeep Anand.Online monitoring technique for aluminum electrolytic capacitor in solar PV-based DC system[J]. IEEE Transactions on Industrial Electronics, 2016, 63(11): 7059-7066. [10] Md Waseem Ahmad, Nikunj Agarwal, Nandha Kumar P, et al.Low-frequency impedance monitoring and corresponding failure criteria for aluminum electrolytic capacitors[J]. IEEE Transactions on Industrial Electronics, 2017, 64(7): 5657-5666. [11] Markus A Vogelsberger, Thomas Wiesinger, Hans Ertl.Life-cycle monitoring and voltage-managing unit for DC-link electrolytic capacitors in PWM converters[J]. IEEE Transactions on Power Elec- tronics, 2011, 26(2): 493-503. [12] Xing-Si Pu, Thanh Hai Nguyen, Dong-Choon Lee, et al.Fault diagnosis of DC-link capacitors in three-phase AC/DC PWM converters by online estimation of equivalent series resistance[J]. IEEE Transactions on Industrial Electronics, 2013, 60(9): 4113-4127. [13] Nikunj Agarwal, Abhinav Arya, Md Waseem Ahmad, et al.Lifetime monitoring of electrolytic capacitor to maximize earnings from grid-feeding PV system[J]. IEEE Transactions on Industrial Electronics, 2016, 63(11): 7049-7058. [14] Maawad Makdessi, Ali Sari, Pascal Venet, et al.Accelerated ageing of metallized film capacitors under high ripple currents combined with a DC voltage[J]. IEEE Transactions on Power Electronics, 2015, 30(5): 2435-2444. [15] Li Zhiwei, Li Hua, Lin Fuchang, et al.Lifetime prediction of metallized film capacitors based on capacitance loss[J]. IEEE Transactions on Plasma Science, 2013, 41(5): 1313-1318. [16] Nikunj Agarwa, Md Waseem Ahmad, Sandeep Anand.Quasi-online technique for health monitoring of capacitor in single phase solar inverter[J]. IEEE Transactions on Power Electronics, 2018, 33(6): 5283-5291. [17] Yvan Avenas, Laurent Dupont, Nick Baker, et al.Condition monitoring: a decade of proposed tech- niques[J]. IEEE Industrial Electronic Magazine, 2015, 9(4): 22-36. [18] 代新, 林福昌, 李劲, 等. 金属化聚丙烯膜脉冲电容器端部接触老化研究[J]. 中国电机工程学报, 2001, 21(8): 51-54. Dai Xin, Lin Fuchang, Li Jin, et al.Electrode-end contact degradation of metallized of polypropylene pulse capacitors[J]. Proceedings of the CSEE, 2001, 21(8): 51-54. [19] 王贺超, 夏长亮, 阎彦, 等. 基于谐振控制的表贴式永磁同步电机弱磁区电流谐波抑制[J]. 电工技术学报, 2014, 29(9): 83-91. Wang Hechao, Xia Changliang, Yan Yan, et al.Current harmonic suppression in the flux-weakening control of surface permanent magnet synchronous motors using resonant controllers[J]. Transactions of China Electrotechnical Society, 2014, 29(9): 83-91. [20] 王翔, 郝瑞祥, 王剑. 变压器直流偏磁对光伏并网逆变器的影响及抑制方法[J]. 电工技术学报, 2013, 28(12): 237-244. Wang Xiang, Hao Ruixiang, Wang Jian.Research on the impact of transformer DC bias on PV grid- connected inverter and restraining method[J]. Transactions of China Electrotechnical Society, 2013, 28(12): 237-244. |
|
|
|