Calculation and Influencing Factors of Icing Freezing Coefficient of Overhead Transmission Line |
He Qing1, Li Junhui1,2, Deng Menyan1, Zhang Jian2, Du Dongmei1 |
1. School of Energy, Power and Mechanical Engineering North China Electric Power University Beijing 102206 China; 2. Power Transmission and Transformation Engineering Department China Electric Power Research Institute Beijing 100055 China |
|
|
Abstract The freezing coefficient is one of the most important parameters in the ice prediction model. In order to improve the calculation accuracy of the freezing coefficient, a new method for calculating the freezing coefficient collision the impact coefficient, the current joule heat and the wire surface temperature is proposed. On this basis, the comprehensive calculation and analysis of the trend of the freezing coefficient obtained by the calculation method before and after the improvement with the main influencing factors are analyzed and compared. Finally, the calculation accuracy of the new method is verified by comparison with the experimental results. The new method of freezing coefficient calculation not only improves the accuracy of ice prediction calculation, but also the influence of parameters such as micro-meteorological environment and wire characteristics on the freezing coefficient.
|
Received: 11 August 2018
Published: 12 October 2019
|
|
|
|
|
[1] 许家浩, 郑伟, 黄宵宁, 等. 微气象条件下输电线路导线覆冰预测模型[J]. 中国电力, 2014, 47(2): 58-63. Xu Jiahao, Zheng Wei, Huang Xiaoning, et al.Transmission line icing prediction model under micro- meteorological conditions[J]. Electric Power, 2014, 47(2): 58-63. [2] 蒋兴良, 马俊, 王少华, 等. 输电线路冰害事故及原因分析[J]. 中国电力, 2005, 38(11): 27-30. Jiang Xingliang, Ma Jun, Wang Shaohua, et al.Analysis of ice accidents and causes of transmission lines[J]. Electric Power, 2005, 38(11): 27-30. [3] 张战恩. 覆冰环境条件下空气横掠导线对流换热问题研究[D]. 长沙: 长沙理工大学, 2011. [4] Peng Jin, Li Yadong, Guo Kunya, et al.Fault probability prediction of transmission lines under icing disaster[C]//IEEE Control and Decision Conference, Chongqing, China, 2017: 6942-6947. [5] 陈凌. 旋转圆柱体覆冰增长模型与线路覆冰参数预测方法研究[D]. 重庆: 重庆大学, 2011. [6] 张暕. 架空输电线路覆冰机理及预测模型的研究[D]. 北京: 华北电力大学, 2018. [7] 朱永灿, 黄新波, 贾建援, 等. 输电导线覆冰生长及影响因素数值分析模型[J]. 西安交通大学学报, 2015, 49(7): 120-125. Zhu Yongcan, Huang Xinbo, Jia Jianwan, et al.Numerical simulation for icing and influence on transmission line[J]. Journal of Xi’an Jiaotong University, 2015, 49(7): 120-125. [8] Farzaneh M.Atmospheric icing of power networks[M]. Berlin: Springer Netherlands, 2008. [9] 张志劲, 黄海舟, 蒋兴良, 等. 复合绝缘子雾凇覆冰厚度预测模型[J]. 电工技术学报, 2014, 29(6): 318-325. Zhang Zhijin, Huang Haizhou, Jiang Xingliang, et al.Model for predicting thickness of rime accreted on composite insulators[J]. Transactions of China Electrotechnical Society, 2014, 29(6): 318-325. [10] Gu Xiaosong, Wang Hanqing, Liu Heyun.Calculation model of ice melting joule heat for overhead lines[C]//International Conference on Electrical & Control Engineering, Wuhan, China, 2010: 5079-5082. [11] 兰强. 抑制导线覆冰的临界电流计算模型与影响因素研究[D]. 重庆: 重庆大学, 2012. [12] 蒋兴良, 申强, 舒立春, 等. 利用旋转多圆柱导体覆冰质量预测湿增长过程覆冰参数[J]. 高电压技术, 2009, 35(12): 3071-3076. Jiang Xingliang, Shen Qiang, Shu Lichun, et al.Prediction of ice coating parameters in wet growth process using radiant multi-cylinder conductor icing quality[J]. High Voltage Engineering, 2009, 35(12): 3071-3076 [13] 韩兴波, 蒋兴良, 毕聪来, 等. 基于分散型旋转圆导体的覆冰参数预测[J]. 电工技术学报, 2019, 34(5): 1096-1105. Han Xingbo, Jiang Xingliang, Bi Conglai, et al.Prediction of icing environment parameters based on decentralized rotating conductors[J]. Transactions of China Electrotechnical Society, 2019, 34(5): 1096-1105. [14] 蒋兴良, 姜方义, 汪泉霖, 等. 基于最优时间步长模型的输电导线雾凇覆冰预测[J]. 电工技术学报, 2018, 33(18): 4408-4418. Jiang Xingliang, Jiang Fangyi, Wang Quanlin, et al.Prediction of rime accretion on transmission line based on optimal time step model[J]. Transactions of China Electrotechnical Society, 2018, 33(18): 4408-4418. [15] 薛艺为, 阳林, 郝艳捧, 等. 输电线路悬式复合绝缘子雨凇与轻雾凇覆冰形态和覆冰过程对比研究[J]. 电工技术学报, 2016, 31(8): 212-219. Xue Yiwei, Yang Lin, Hao Yanpeng, et al.A comparative study on icing morphology and process of glaze and light rime in suspension composite insulators on transmission lines[J]. Transactions of China Electrotechnical Society, 2016, 31(8): 212-219. [16] 刘国特, 郝艳捧, 阳林, 等. 基于改进Messinger覆冰模型导线防冰临界电流计算及其影响因素分析[J]. 电工技术学报, 2016, 31(18): 176-183. Liu Guote, Hao Yanzhan, Yang Lin, et al.Calculation of critical ice current and its influencing factors based on improved Messinger ice-covered model[J]. Transactions of China Electrotechnical Society, 2016, 31(18): 176-183. [17] 刘胜春, 司佳钧, 郭昊, 等. 输电线路导线覆冰模拟计算与试验研究[J]. 中国电机工程学报, 2014, 34(增刊1): 246-255. Liu Shengchun, Si Jiazhen, Guo Hao, et al.Simulation calculation and experimental study of conductor wire icing[J]. Proceedings of the CSEE, 2014, 34(S1): 246-255. |
|
|
|