Open Circuit Fault Diagnosis of T-Type Inverter |
Ma Xiaojun, Li Minyu, Wei Shuguang, Shi Hao |
Department of Control Engineering Academy of Armored Force Engineering Beijing 100072 China; |
|
|
Abstract In this paper, the variations of load current and bus capacitor voltage in the case of open circuit fault of T-type inverter are analyzed. Then the fault characteristics of different open circuit switches are summarized. A fault diagnosis strategy based on load current and bus capacitor voltage variation law is proposed. Firstly, the fault of the inverter is judged by detecting bus capacitor voltage. The modulation ratio is limited to 0.25 after the fault is then detected. Finally, the precise location of the fault switch is realized by judging the variation law of load current and bus capacitor voltage in different sectors. The proposed fault diagnosis strategy does not need additional sensors, and it is easy to implement in engineering. Simulation and experimental results verify the feasibility of the proposed fault diagnosis strategy.
|
Received: 10 February 2017
Published: 24 May 2018
|
|
|
|
|
[1] Schweizer M, Kolar J W.Design and implementation of a highly efficient three-level T-type converter for low-voltage applications[J]. IEEE Transactions on Power Electronics, 2013, 28(2): 899-907. [2] Gu Mingchen, Xu Peng, Zhang Li, et al.A SiC-based T-type three-phase three-level grid tied inverter[C]// IEEE 10th Conference on Industrial Electronics and Applications (ICIEA), Auckland, New Zealand, 2015: 1116-1121. [3] 杨龙飞. 基于T型三电平技术的储能变流器研究[D]. 北京: 北京交通大学, 2013. [4] 夏玲芳. T型三电平逆变器技术研究[D]. 南京: 南京航空航天大学, 2014. [5] 王若醒, 吴迎霞, 杨恢宏, 等. 两级式T型三电平光伏逆变器的关键技术研究及实现[J]. 电力系统保护与控制, 2015, 43(4): 58-62. Wang Ruoxing, Wu Yingxia, Yang Huihong, et al.Research on key technologies of double-stage T-type three-level photovoltaic inverter[J]. Power System Protection and Control, 2015, 43(4): 58-62. [6] Bin Lu.A literature review of IGBT fault diagnostic and protection methods for power inverters[J]. IEEE Transactions on Industry Applications, 2009, 45(5): 1770-1777. [7] 安群涛, 孙力, 孙立志, 等. 三相逆变器开关管故障诊断方法研究进展[J]. 电工技术学报, 2011, 26(4): 135-144. An Quntao, Sun Li, Sun Lizhi, et al.Recent developments of fault diagnosis methods for switches in three-phase inverters[J]. Transactions of China Electrotechnical Society, 2011, 26(4): 135-144. [8] 徐殿国, 刘晓峰, 于泳. 变频器故障诊断及容错控制研究综述[J]. 电工技术学报, 2015, 30(21): 1-12. Xu Dianguo, Liu Xiaofeng, Yu Yong.A survey on fault diagnosis and tolerant control of inverters[J]. Transactions of China Electrotechnical Society, 2015, 30(21): 1-12. [9] 于泳, 蒋生成, 杨荣峰, 等. 变频器IGBT开路故障诊断方法[J]. 中国电机工程学报, 2011, 31(9): 30-35. Yu Yong, Jiang Shengcheng, Yang Rongfeng, et al.IGBT open circuit fault diagnosis method for inverter[J]. Proceedings of the CSEE, 2011, 31(9): 30-35. [10] Wojciech Sleszynski, Janusz Nieznanski.Open transistor fault diagnostics in voltage-source inverters by analyzing the load currents[J]. IEEE Transactions on Industrial Electronics, 2009, 56(11): 4681-4688. [11] Estima J O, Cardoso A J M. A new approach for real-time multiple open-circuit fault diagnosis in voltage-source inverters[J]. IEEE Transactions on Industry Applications, 2011, 47(6): 2487-2494. [12] Ui Min Choi, Hae Gwang Jeong, Kyo Beum Lee, et al.Method for detecting an open-switch fault in a grid-connected NPC inverter system[J]. IEEE Transa- ctions on Power Electronics, 2012, 27(6): 2726-2739. [13] 汤清泉, 颜世超, 卢松升, 等. 三电平逆变器的功率管开路故障诊断[J]. 中国电机工程学报, 2008, 28(21): 26-32. Tang Qingquan, Yan Shichao, Lu Songsheng, et al.Open-circuit fault diagnosis of transistor in three- level inverter[J]. Proceedings of the CSEE, 2008, 28(21): 26-32. [14] 陈丹江, 叶银忠, 华容. 基于波形实时分析的动车组三电平逆变器故障诊断技术[J]. 电工技术学报, 2014, 29(6): 106-113. Chen Danjiang, Ye Yinzhong, Hua Rong.Fault diagnosis for three-level inverter of CRH based on real-time waveform analysis[J]. Transactions of China Electrotechnical Society, 2014, 29(6): 106-113. [15] 崔江, 王强, 龚春英. 结合小波与Concordia变换的逆变器功率管故障诊断技术研究[J]. 中国电机工程学报, 2015, 35(12): 3110-3116. Cui Jiang, Wang Qiang, Gong Chunying.Inverter power switch fault diagnosis technique research based on wavelet and concordia transform[J]. Proceedings of the CSEE, 2015, 35(12): 3110-3116. [16] 陈丹江, 叶银忠. 基于多神经网络的三电平逆变器器件开路故障诊断方法[J]. 电工技术学报, 2013, 28(6): 120-126. Chen Danjian, Ye Yinzhong.Fault diagnosis of three level inverter based on multi neural network[J]. Transactions of China Electrotechnical Society, 2013, 28(6): 120-126. [17] 于生宝, 何建龙, 王睿家, 等. 基于小波包分析和概率神经网络的电磁法三电平变换器故障诊断方法[J]. 电工技术学报, 2016, 31(17): 102-112. Yu Shengbao, He Jianlong, Wang Ruijia, et al.Fault diagnosis of electromagnetic three-level inverter based on wavelet packet analysis and probabilistic neural networks[J]. Transactions of China Electro- technical Society, 2016, 31(17): 102-112. [18] 姜卫东, 王群京, 史晓锋, 等. 中点箝位型三电平逆变器在空间矢量调制时中点电位的低频振荡[J].中国电机工程学报, 2009, 29(3): 49-55. Jiang Weidong, Wang Qunjing, Shi Xiaofeng, et al.Low frequency oscillation of neutral point voltage of neutral-point-clamped three-level VSI under SVPWM control[J]. Proceedings of the CSEE, 2009, 29(3): 49-55. [19] 张兵, 王政, 储凯, 等. NPC型三电平逆变器容错控制模式下的母线电容电压波动分析及其抑制[J].电工技术学报, 2015, 30(7): 52-61. Zhang Bing, Wang Zheng, Chu Kai, et al.Analysis of fluctuation in DC link capacitor voltage of NPC three-level inverter and its mitigation under fault tolerant control mode[J]. Transactions of China Electrotechnical Society, 2015, 30(7): 52-61. |
|
|
|