Adaptive Filter Application in Current Vector Dead Time Compensation |
Yang Rongfeng, Chen Wei, Yu Yong, Xu Dianguo |
Harbin Institute of Technology Harbin 150001 China |
|
|
Abstract An adaptive filter method is proposed that extracts the DC components of the d-q frame current to compensate the dead-time effect in pulse width modulation( PWM) for inverter control. In addition to current space vector compensation method, phase current noise negative influence to this method is discussed. To eliminate the noise, an effective adaptive filter and its related dynamic convergence parameter method are presented which are simple and easy for application. Measured results demonstrate this method can obtain precise d-q frame current and compensate the dead time voltage properly.
|
Received: 30 January 2008
Published: 17 February 2014
|
|
|
|
|
[1] Naomitsu Urasaki, Tomonobu Senjyu, Katsumi Uezato, et al. On-line dead-time compensation method for voltage source inverter fed motor drives[J]. Applied Power Electronics Conference and Exposition, 19th Annual IEEE, 2004, 1: 122-127. [2] 窦汝振, 刘钧, 温旭辉. SVPWM控制逆变器死区补偿方法的研究[J]. 电力电子技术, 2004, 38(6): 59- 61. [3] 徐德丰, 韩中林, 洪雷. PWM控制方式下死区对变频器性能的影响分析[J]. 低压电器, 2004(12): 53- 57. [4] Hyun Soo Kim, Kyeong Hwa Kim, Myung Joong Youn. On-line dead-time compensation method based on time delay control[J]. IEEE Transactions on Control Systems Technology, 2003, 11(2): 279-285. [5] Kim S H, Park T S, Yoo J Y, et al. Dead time compen- sation in a vector-controlled induction machine[C]. PESC 98 Record. 29th Annual IEEE, 1998, 2: 1011- 1016. [6] 郑伟, 季筱隆, 刘玮, 等. 一种基于电流矢量的死区时间补偿方案[J]. 电气传动, 2005, 35(4): 34-36. |
|
|
|