[1] Bagshaw A P, Liston A D, Bayford R H, et al. Electrical impedance tomography of human brain function using reconstruction algorithms based on the finite element method[J]. Neuroimage, 2003, 20(2): 752-764.
[2] Seagar A D, Barber D C, Brown B H. Thepretical limits to sensitivity and resolution in impedance imaging[J]. Clinical Physics and Physiological Measurement, 1987, 8(Supp.A): 13-31.
[3] Cherepenin V, Karpov A, Korjenevsky A, et al. A 3D electrical impedance tomography system for breast cancer detection[J]. Physiological Measurement. 2001, 22(1): 9-18.
[4] Seo J K, Pyo H C, Park C, et al. Image reconstruction of anisotropic conductivity tensor distribution in MREIT: computer simulation study[J]. Physics in Medicine and Biology, 2004, 49(5): 4371-4382.
[5] 付志红, 余慈拱, 侯兴哲, 等. 瞬变电磁法视电阻率成像的接地网断点诊断方法[J]. 电工技术学报, 2014, 29(9): 253-259. Fu Zhihong, Yu Cigong, Hou Xingzhe, et al. Transient electromagnetic apparent resistivity imaging for break point diagnosis of grounding grids[J]. Transactions of Electrotechnical Society, 2014, 29(9): 253-259.
[6] 刘瑞芳, 李俊峰, 桑秉谦, 等. 基于电磁场数值计算的变频供电感应电机耦合电容与轴电压的分析[J]. 电工技术学报, 2015, 30(14): 161-169. Liu Ruifang, Li Junfeng, Sang Bingqian, et al. Modeling of coupled capacitances and bearing voltage in induction motors fed by inverters based on numerical calculation of electromagnetic field[J]. Transactions of Electrotechnical Society, 2015, 30(14): 161-169.
[7] Kuchment P, Kunyansky L. Synthetic focusing in ultrasound modulated tomography[J]. Inverse Pro- blems and Imaging, 2010, 4(4): 665-673.
[8] Kuchment P. Mathematics of hybrid imaging: a brief review[J]. Mathematical Legacy of Leon Ehrenpreis, 2011, 1(16): 183-208.
[9] 陈民铀, 高兵, 杨帆, 等. 基于电-热-机械应力多物理场的IGBT焊料层健康状态研究[J]. 电工技术学报, 2015, 30(20): 252-260. Chen Minyou, Gao Bing, Yang Fan, et al. Healthy evaluation on IGBT solder based on electro-thermal- mechanical analysis[J]. Transactions of Electro- technical Society, 2015, 30(20): 252-260.
[10] Xu Y, He B. Magnetoacoustic tomography with magnetic induction (MAT-MI)[J]. Physics in Medi- cine and Biology, 2005, 50(21): 5175-5187.
[11] Li Y L, Ma Q Y, Zhang D, et al. Acoustic dipole radiation model for magnetoacoustic tomography with magnetic induction[J]. Chinese Physics B, 2011, 20(8): 084302(1-3).
[12] Liu G Q, Huang X, Xia H, et al. Magnetoacoustic tomography with current injection[J]. Chinese Science Bulletin, 2013, 58(1): 3600-3606.
[13] 林颖, 郭志红, 陈玉峰. 基于卷积递归网络的电流互感器红外故障图像诊断[J]. 电力系统保护与控制, 2015, 43(16): 87-94. Lin Ying, Guo Zhihong, Chen Yufeng. Convolutional- recursive network based current transformer infrared fault image diagnosis[J]. Power System Protection and Control, 2015, 43(16): 87-94.
[14] Xu Y, Wang L V. Time resversal and its apllication to tomography with diffracting sources[J]. Physical Review Letters, 2004, 92(3): 033902(1-8).
[15] 刘国强. 医学电磁成像[M]. 北京: 科学出版社, 2006. |