Transactions of China Electrotechnical Society  2016, Vol. 31 Issue (20): 202-208    DOI:
Orginal Article Current Issue| Next Issue| Archive| Adv Search |
Calculation and Analysis of the Safe Operation Boundary of Shipboard DC Zonal Electric Distribution System
Xiao Han, Ye Zhihao, Ma Fan, Ji Feng
National Key Laboratory of Science and Technology on Vessel Integrated Power System Naval University of Engineering Wuhan 430033 China

Download: PDF (14787 KB)   HTML (1 KB) 
Export: BibTeX | EndNote (RIS)      
Abstract  The new characteristics of the integrated power system (IPS) exist by using DC zonal electrical distribution and the concept of the total supply capability (TSC) in distribution network. This paper presented a safety domain model and a TSC model for the DC zonal electrical distribution system based on the chopper load rate. The concept of {1}-generalized inverse matrix was also introduced to analyze the solution space form of the safety domain model. Furthermore, the visual safe boundary simulation algorithm was adopted to solve the TSC model, and the result was used as the initial iteration value. Then, the choppers in the DC zonal electrical distribution system were paired up. Each group would be selected for the approximating simulation, and a two-dimensional safe boundary section profile was obtained. Finally, Lingo was applied to calculating the TSC critical safety working point. The safe boundary section profiles of the two typical groups were offered, and the load relationship between the choppers in the same region and different regions was analyzed. This paper provides the basis to study the safe and preventive control of the IPS.
Key wordsDC zonal electrical distribution      chopper load rate      the safety domain      total supply capability      safe boundary     
Received: 16 December 2015      Published: 01 November 2016
PACS: TM71  
Service
E-mail this article
Add to my bookshelf
Add to citation manager
E-mail Alert
RSS
Articles by authors
Xiao Han
Ye Zhihao
Ma Fan
Ji Feng
Cite this article:   
Xiao Han,Ye Zhihao,Ma Fan等. Calculation and Analysis of the Safe Operation Boundary of Shipboard DC Zonal Electric Distribution System[J]. Transactions of China Electrotechnical Society, 2016, 31(20): 202-208.
URL:  
https://dgjsxb.ces-transaction.com/EN/     OR     https://dgjsxb.ces-transaction.com/EN/Y2016/V31/I20/202
Copyright © Transactions of China Electrotechnical Society
Supported by: Beijing Magtech