An Extended Dynamic Optimization Model for AGC Generators Dispatch Under CPS |
Zhao Xia1,Zhang Rongrong1,Zhao Ruifeng2,Yan Wei1,Yu Juan1 |
1.State Key Laboratory of Power Transmission Equipment & System Security and New Technology Chongqing University Chongqing 400030 China; 2.Electric Power Dispatching Control Centre of GDPC Guangzhou 510600 China |
|
|
Abstract In order to overcome the problem of the lagging control within the conventional automatic generation control (AGC) and improve the adaptability of the interconnected power system to the new control performance standard (CPS),the dynamic optimization model for AGC generators dispatch has been proposed.However,the existing model still have some defects,such as neglecting the effect of network security constraints and power loss,etc.An extended dynamic optimization model for AGC generators dispatch under CPS is thus proposed in this paper with the following modifications:①the active power loss and the loading limits through the branches and boundaries are integrated;②the original objective of ancillary service cost is revised;and ③the completion of electricity production contract is added as a new objective function.The modified IEEE 14-bus test system is used to verify the extended model and the physical interpretations of treating the CPS1 index as an objective and/or a constraint are also discussed.
|
Received: 23 June 2015
Published: 16 March 2016
|
|
|
|
|
[1] Jaleeli N,Vanslyck L S,Ewart D,et al.Understanding automatic generation control[J].IEEE Transactions on Power System,1992,7(3):1106-1122. [2] Ibraheem,Kumar P,Kothari D P.Recent philosophies of automatic generation control strategies in power systems[J].IEEE Transactions on Power Systems,2005,20(1):346-357. [3] 颜伟,赵瑞锋,赵霞,等.自动发电控制中控制策略研究发展综述[J].电力系统保护与控制,2013,41(8):149-155. Yan Wei,Zhao Ruifeng,Zhao Xia,et al.Review on control strategies in automatic generation control[J].Power System Protection and Control,2013,41(8):149-155. [4] 高宗和,滕贤亮,张小白.互联电网CPS标准下的自动发电控制策略[J].电力系统自动化,2005,29(19):40-44. Gao Zonghe,Teng Xianliang,Zhang Xiaobai.Automatic generation control strategy under control performance standard for interconnected power system[J].Automation of Electric Power Systems,2005,29(19):40-44. [5] 余涛,周斌,陈家荣.基于多步回溯Q(λ)学习的互联电网随机最优CPS控制[J].电工技术学报,2011,26(6):179-186. Yu Tao,Zhou Bin,Chan Jiarong.Stochastic optimal CPS control for interconnected power girds using multi-step backtrack Q(λ) learning[J].Transactions of China Electrotechnical Society,2011,26(6):179-186. [6] Rishabh V,Shalini P,Sathans S.Intelligent automatic generation control of two-area hydrothermal power system using ANN and fuzzy logic[C]//IEEE International Conference on Communication Systems and Network Technologies,Gwalior,2013:552-556. [7] Sahu R K,Panda S,Sekhar G T C.A novel hybrid PSO-PS optimized fuzzy PI controller for AGC in multi area interconnected power systems[J].International Journal of Electrical Power and Energy Systems,2015,64(1):880-893. [8] Bevrani H,Daneshfar F,Hiyama T.A new intelligent agent-based AGC design with real-time Application[J].IEEE Transactions on Systems,Man,and Cybernetics,Part C:Applications and Reviews,2012,42(6):994-1002. [9] 余涛,周斌.基于强化学习的互联电网CPS自校正控制[J].电力系统保护与控制,2009,37(10):33-38. Yu Tao,Zhou Bin.Reinforcement learning based CPS self-tuning control methodology for interconnected power system[J].Power System Protection and Control,2009,37(10):33-38. [10]Banakar H,Luo Changling,Boon T O.Impacts of wind power minute-to-minute variations on power system operation[J].IEEE Transactions on Power Systems,2008,23(1):150-160. [11]Jaleeli N,Vanslyck L S.NERC’s new control performance standards[J].IEEE Transactions on Power Systems,1999,14(3):1092-1099. [12]高宗和,丁恰,温柏坚,等.利用超短期负荷预报实现AGC的超前控制[J].电力系统自动化,2000,24(11):42-44. Gao Zonghe,Ding Qia,Wen Bojian,et al.AGC-in-advance based on super-short-term load forecasting[J].Automation of Electric Power Systems,2000,24(11):42-44. [13]陈铭,刘娆,吕泉,等.AGC机组分群控制策略[J].电网技术,2013,37(3):868-873. Chen Ming,Liu Rao,Lü Quan,et al.A grouping control strategy for AGC units[J].Power Systems Technology,2013,37(3):868-873. [14]李树山,廖胜利,申建建,等.厂网协调模式下梯级AGC控制策略[J].中国电机工程学报,2014,34(7):1113-1123. Li Shushan,Liao Shengli,Shen Jianjian,et al.Automatic generation control strategies of cascaded hydropower plants oriented to the coordination of power plants and power grids[J].Proceedings of the CSEE,2014,34(7):1113-1123. [15]李滨,韦化,农蔚涛,等.基于现代内点理论的互联电网控制性能评价标准下的AGC控制策略[J].中国电机工程学报,2008,28(25):56-61. Li Bin,Wei Hua,Nong Weitao,et al.AGC control strategy under control performance standard for interconnected power gird based on optimization theory[J].Proceeding of the CSEE,2008,28(25):56-61. [16]Yan Wei,Zhao Ruifeng,Zhao Xia,et al.Dynamic optimization model of AGC strategy under CPS for interconnected power system[J].International Review of Electrical Engineering,2012,7(5):5733-5743. [17]赵瑞锋.互联电网AGC的动态优化策略及其在线计算平台研究[D].重庆:重庆大学,2013. [18]Zhang P.CPS Based Control Algorithms for Modern AGC Systems[R].California:California Independent System Operator(CAISO),2002. [19]巴宇,刘娆,李卫东.CPS及其考核在北美与国内的应用对比[J].电力系统自动化,2012,36(15):63-72. Ba Yu,Liu Rao,Li Weidong.Comparison of CPS and its assessment between North America and China[J].Automation of Electric Power Systems,2012,36(15):63-72. [20]汪德星.关于CPS应用的学术讨论[J].电力系统自动化,2012,36(15):73-77,82. Wang Dexing.Academic discussions on CPS application[J].Automation of Electric Power Systems,2012,36(15):73-77,82. [21]黄韬,王坚.南方电网频率控制性能标准考核方法探讨[J].南方电网技术,2012,6(1):34-37. Huang Tao,Wang Jian.On the frequency-control performance standard for china southern power grid[J].Southern Power System Technology,2012,6(1):34-37. [22]葛炬,张粒子,周小兵,等.AGC机组参与电力市场辅助服务的探讨[J].电网技术,2002,26(12):61-65. Ge Ju,Zhang Lizi,Zhou Xiaobing,et al.Discussion on AGC units participating ancillary services in electricity market[J].Power System Technology,2002,26(12):61-65. [23]Cardell J B.Marginal loss pricing for hours with transmission congestion[J].IEEE Transactions on Power Systems,2007,22(4):1466-1474. [24]朱泽磊,周京阳,潘毅,等.考虑电力电量平衡的安全约束经济调度[J].中国电机工程学报,2013,33(10):168-176. Zhu Zelei,Zhou Jingyang,Pan Yi,et al.Constrained economic dispatch considering balance of electric power and energy[J].Proceedings of the CSEE,2013,33(10):168-176.
|
|
|
|