Abstract Two novel experimental methods of acquiring dq inductance of permanent magnet synchronous motors(PMSM) are presented to improve the previous experimental methods. Based on the experimental wiring diagrams, the mathematical models of equivalent impedances of PMSM in the motor terminals are derived by impedance decoupling analysis. It is revealed that with the different position of the motor rotor, there are specific multiple relationships between the terminal equivalent inductance and dq inductance when the modulus of terminal equivalent impedances is in minimum or maximum. Some previous researches indicate that with conventional AC method, dq inductance is less affected by AC armature currents, so the methods presented in this paper are valid to quickly and effectively acquire the dq inductance by simply rotating the rotor with hand and measuring the impedance with test instruments. The methods are approved to be effective and practicable by the practical test with some PMSM.
|
Received: 17 April 2013
Published: 05 August 2014
|
|
|
|
|
[1] Pillay P, Krishnan R. Modeling, simulation, and analysis of permanent-magnet motor drives, part I: the permanent-magnet synchronous motor drive[J]. IEEE Transactions on Industry Applications, 1989, 25(2): 265-273. [2] 唐任远. 现代永磁电机与理论[M]. 北京: 机械工业出版社, 1997. [3] Rahman M A, Vilathgamuwa D M, Uddin M N, et al. Nonlinear control of interior permanent-magnet synchronous motor[J]. IEEE Transactions on Industry Applications, 2003, 39(2): 408-416. [4] Sun T, Kwon S O, Lee S H, et al. Investigation and comparison of inductance calculation methods in interior permanent magnet synchronous motors[C]. Proceedings of the 11th International Conference on Electrical Machines and Systems, Wuhan, China, 2008: 3131-3136. [5] 王宏, 于泳, 徐殿国.永磁同步电机位置伺服系统[J]. 中国电机工程学报, 2004, 24(7): 151-155. Wang Hong, Yu Yong, Xu Dianguo. The position servo system of PMSM[J]. Proceedings of the CSEE, 2004, 24(7): 151-155. [6] Chen W, Lee F C, Zhou X, et al. Integrated planar inductor scheme for multi-module interleaved quasi- square-wave(QSW) DC/DC converter[C]. IEEE Power Electronics Specialists Conference, 1999: 759-762. [7] 陈为, 何建农. 电力电子高频磁技术及其发展趋势[J]. 电工电能新技术, 2000, 19(2): 30-34. Chen Wei, He Jiannong. Power electronics high- frequency magnetics technology and their development [J]. Advanced Technology of Electrical Engineering and Energy, 2000, 19(2): 30-34. [8] 卢增艺, 陈为, 白亚东, 等. 一种新型磁集成倍流整流半桥变换器[J]. 中国电机工程学报, 2011, 31(15): 15-21. Lu Zengyi, Chen Wei, Bai Yadong, et al. A novel half-bridge converter with integrated magnetic current doubler rectifier[J]. Proceedings of the CSEE, 2011, 31(15): 15-21. [9] Blaschke F. The principle of field orientation as applied to the new transvektor closed-loop control system for rotating-field machines[J]. Siemens Review, 1972, 34(5): 217-220. [10] Leonhard W. Control of electrical drives[M]. 3rd ed. New York: Springer, 2001. [11] IEEE GUIDE: Test procedures for synchronous machine, Part I-Acceptance and performance testing, Part II-Test procedures and parameter determination for dynamic analysis[Z]. IEEE Standard 115-1995, 1995. [12] IEEE standard procedures for obtaining synchronous machine parameters by standstill frequency response testing[S]. IEEE Standard 115A-1987, 1987. [13] Dutta R, Rahman M F. A comparative analysis of two test methods of measuring d- and q-Axes inductances of interior permanent-magnet machine[J]. IEEE Transactions on Magnetics, 2006, 42(11): 3712-3718. [14] Gieras J F, Santini E, Wing M. Calculation of synchronous reactances of small permanent-magnet alternating-current motors: comparison of analytical approach and finite element method with measurements [J]. IEEE Transactions on Magnetics, 1998, 34(5): 3712-3720. [15] Nakatsugawa J, Notohara Y, Li D S, et al. Inductance measurement method for permanent magnet synchronous motors using AC with DC bias[C]. 8th International Conference on Electrical Machines, 2008: 1-4. [16] Gieras J F, Wing M. Permanent magnet motor technology: design and applications[M]. 3rd ed. New York: CRC, 2010. [17] Rahman K M, Hiti S. Identification of machine parameters of a synchronous motor[J]. IEEE Transac- tions on Industry Applications, 2005, 41(2): 557-565. [18] Fitzgerald A E, Kingsley C, Umans S D.Electric machinery[M]. 6th ed. 北京: 清华大学出版社, 2003. [19] 王秀和. 永磁电机[M]. 2版. 北京: 中国电力出版社, 2010. [20] Gebregergis A, Islam M, Sebastian T, et al. Evaluation of inductance in a permanent magnet synchronous motor[C]. IEEE International Conference on Electric Machines & Drives(IEMDC), 2011: 1171-1176. [21] 汪海波, 周波, 方斯琛. 永磁同步电机调速系统的滑模控制[J]. 电工技术学报, 2009, 24(9): 71-77. Wang Haibo, Zhou Bo, Fang Sichen. A PMSM sliding mode control system based on exponential reaching law[J]. Transactions of China Electrotechnical Society, 2009, 24(9): 71-77. [22] 黄佳佳, 周波, 李丹, 等. 滑模控制永磁同步电动机位置伺服系统抖振[J]. 电工技术学报, 2009, 24(11): 41-47. Huang Jiajia, Zhou Bo, Li Dan, et al. Sliding mode control for permanent magnet synchronous motor servo system[J]. Transactions of China Electrotechnical Society, 2009, 24(11): 41-47. [23] 刘栋良, 王家军, 崔丽丽. 永磁同步电机参数自适应调速控制[J]. 电工技术学报, 2011, 26(8): 159-165. Liu Dongliang, Wang Jiajun, Cui Lili. Speed tracking control of permanent magnet synchronous motors with adaptive parameters[J]. Transactions of China Electrotechnical Society, 2011, 26(8): 159-165. [24] 刘婷婷, 谭彧, 吴刚, 等. 基于SVPWM的高转速永磁同步电机控制系统的研究[J]. 电力系统保护与控制, 2009, 37(12): 11-19. Liu Tingting, Tan Yu, Wu Gang, et al. Simulating of high speed PMSM control system based on SVPWM [J]. Power System Protection and Control, 2009, 37(12): 11-19. [25] 程启明, 程尹曼, 王映斐, 等. 交流电机控制策略的发展综述[J]. 电力系统保护与控制, 2011, 39(9): 145-154. Cheng Qiming, Cheng Yinman, Wang Yingfei, et al. Overview of control strategies for AC motor[J]. Power System Protection and Control, 2011, 39(9): 145-154. [26] 郝正航, 余贻鑫. 双馈风力发电机组对电力系统稳定性影响[J]. 电力系统保护与控制, 2011, 39(3): 7-17. Hao Zhenghang, Yu Yixin. The influence of doubly- fed induction generator on stability of power system [J]. Power System Protection and Control, 2011, 39(3): 7-17. [27] Stumberger B, Stumberger G, Dolinar D, et al. Evaluation of saturation and cross-magnetization effects in interior permanent-magnet synchronous motor[J]. IEEE Transactions on Industry Applications, 2003, 39(5): 1264-1271. |
|
|
|