Topology Synthesis of Hybrid Buck Three-Level Converter and Its Operation Control with Extreme Low Voltage-Gain |
Zhang Yun1, Wang Yifeng1, Shao Hongjun1, Sun Jiantao2 |
1. School of Electrical Engineering and Automation Tianjin University Tianjin 300072 China 2. China Electric Power Research Institute Beijing 100192 China |
|
|
Abstract In order to satisfy the high step-down conversion demand of the DC zonal electric distribution system on the ship, two quasi Buck three-level DC-DC converters are deduced based on the traditional single-phase diode-clamped three-level inverter. Then a novel hybrid Buck three-level converter is synthesized by the mode of the “input sides in parallel—output sides in series” of the two quasi converters. The double-wave PWM control method is adopted, and it can not only operate with transformerless extreme low voltage-gain, but also avoid extreme duty cycles of the power switches. The restricted functions of the double-wave indexes are established by means of the given ranges of the voltage gains and duty cycles, then the harmonic control method for the non-extreme duty cycles and the fluctuating amplitude of the inductor current can be obtained. Finally, the feasibility and validity of the proposed topology and control method are verified by two groups of typical experiments.
|
Received: 17 September 2012
Published: 25 March 2014
|
|
|
|
|
[1] 马伟明. 舰船动力发展的方向——综合电力系统[J]. 海军工程大学学报, 2002, 14(6): 1-5, 9. [2] 马伟明. 电力电子在舰船电力系统中的典型应用[J]. 电工技术学报, 2011, 26(5): 1-7. [3] Ciezki J, Ashton R. Selection and stability issues associated with a navy shipboard DC zonal electric distribution system[J]. IEEE Transactions on Power Delivery, 2000, 15(2): 665-669. [4] Certuche Alzate J, Vélez Reyes M. A reconfiguration algorithm for a DC zonal electric distribution system based on graph theory methods[C]. Electric Ship Technologies Symposium, 2009: 235-241. [5] Su C, Yeh C. Probabilistic security analysis of shipboard DC zonal electrical distribution systems[C]. Power and Energy Society General Meeting, 2008: 1-7. [6] Elshaer M, Mohamed A, Mohammed O. Integration of sustainable energy sources into DC zonal electric distribution systems[C]. Power and Energy Society General Meeting, 2011: 1-7. [7] Song B, McDowell R, Bushnell A, et al. A three-level DC-DC converter with wide-input voltage operations for ship-electric-power-distribution systems[J]. IEEE Transactions on Plasma Science, 2004, 32(5): 1856-1863. [8] Cuzner R, Bendre A, Widmann J, et al. Considerations when diode auctioneering multiple DC buses in a non-isolated DC distribution system[C]. Electric Ship Technologies Symposium, 2011: 277-282. [9] 阮新波, 李斌, 陈乾宏. 一种适用于高压大功率变换器的三电平直流变换器[J]. 中国电机工程学报, 2003, 23(5): 19-23. [10] Wu Hongyang, He Xiangning. Single phase three-level power factor correction circuit with passive lossless snubber[J]. IEEE Transactions on Power Electronics, 2002, 17(6): 946-957. [11] 张云, 孙力, 吴凤江, 等. 电容箝位型非对称H桥五电平逆变器正弦脉宽调制控制[J]. 中国电机工程学报, 2009, 29(21): 40-45. [12] 阮新波, 危健, 薛雅丽. 非隔离三电平变换器中分压电容均压的一种方法[J]. 中国电机工程学报, 2003, 23(10): 27-31. |
|
|
|