| Research on Unbalanced Arcing Characteristics of Bridge-Type Double-Breakpoint DC Electrical Apparatus |
| Huang Jinglong, Deng Chuanchuan, Wei Feng, Sun Mengyao, Liu Xiangjun |
| College of Electrical Engineering and Automation Fuzhou University Fuzhou 350108 China |
|
|
|
Abstract The bridge-type double-break DC electrical apparatus relies on two series-connected breaks to jointly perform circuit breaking, significantly enhancing breaking capacity. It features a small, compact structure with rectangular permanent magnets for magnetic blowout arc extinction. The non-uniform magnetic field generated by the permanent magnets significantly affects the arc's dynamic characteristics. Due to the randomness of the arcing process and potential imbalances in the arc-extinguishing chamber, the unbalanced arcing phenomenon often occurs between two pairs of contacts during the breaking process of bridge-type double-break DC electrical apparatus. As a result, uneven distribution of arc energy leads to differences in erosion, significantly reducing electrical life and reliability. Therefore, based on the theory of electromagnetic fields and magnetohydrodynamics, this paper establishes a direct-coupled three-dimensional permanent-magnet magnetic blowing-arc simulation model and enables real-time interactive calculation of the magnetic field and arc plasma across multiple physical fields. The influence of unbalanced factors, such as the permanent magnet magnetic field, contact-breaking speed, and arcing position, on arcing characteristics is analyzed. The simulation results show that: (1) The magnetic field generated by the rectangular permanent magnet is unevenly distributed, and the magnetic induction line diffuses and attenuates outward from the magnetization direction. The arc is subjected to the Lorentz force in this field. Moreover, because the direction of the magnetic induction lines changes continuously, the magnitude and direction of the force vary continuously. Thus, the arc moves both toward vertical magnetization and toward the permanent magnet. In severe cases, the arc may contact the surface of the permanent magnet, causing irreversible demagnetization. (2) When the magnetic field of the permanent magnet on both sides is seriously unbalanced, the contact on one side bears significantly increased electric field strength and arc energy. The side is more likely to reach the critical breakdown field strength, leading to arc reignition and prolonged arc duration. In addition, the asynchronous breaking of contact and the imbalance of the arc starting point greatly prolong the arc blowing stage on one side of the contact, form a significant difference in arc voltage and energy, and aggravate the unbalanced ablation of the two contacts. The experimental results show that the arc characteristics are basically consistent with the simulation results. Within a certain range, the arc reignition probability increases with increasing magnetic field imbalance. A decay of residual magnetism in a one-sided permanent magnet to 80% results in a 42.5% reignition probability. Further decay to 50% raises the probability to 72.5%. At the same time, an unbalanced break between the two contacts significantly distorts the distribution of arc voltage and arc energy. When the difference in breaking speed reaches 500 mm/s, the arc energy of the faster contact is about 58.6% higher than that of the other one. Therefore, the synchronization of contact breaking must be strictly controlled to prevent uneven distribution of arc energy caused by differences in arc initiation position and timing.
|
|
Received: 28 September 2025
|
|
|
|
|
|
[1] 谢黄涛, 宋威, 朱梓航, 等. 不同磁场下高压直流继电器电弧运动特性研究[J]. 电工技术, 2026(1): 182-187, 190. Xie Huangtao, Song Wei, Zhu Zihang, et al.Research on the arc motion characteristics of high voltage direct current relays under different magnetic field intensities[J]. Electric Engineering, 2026(1): 182-187, 190. [2] Bo Kai, Zhou Xue, Zhai Guofu.Simulation of arc dwelling behavior during bridge-type contacts opening process for high-power relay[J]. IEEE Transactions on Components, Packaging and Manufacturing Tech-nology, 2018, 8(6): 975-981. [3] 吴承创. 触桥结构电侵蚀表征方法与分合性能退化机理的研究[D]. 哈尔滨: 哈尔滨工业大学, 2025. Wu Chengchuang.Research on the characterization method of electrical erosion and switching characte-ristics degradation mechanisms of bridge contact structures[D]. Harbin: Harbin Institute of Technology, 2025. [4] 杨文英, 潘宇航, 鲍家璇, 等. 温振多维应力下航天电磁继电器动态特性和抗振性能研究[J]. 电工技术学报, 2025, 40(19): 6317-6328. Yang Wenying, Pan Yuhang, Bao Jiaxuan, et al.Study on the dynamic characteristics and failure mechanism of aerospace electromagnetic relays under multidimensional stress of temperature-vibration interaction[J]. Transactions of China Electrotechnical Society, 2025, 40(19): 6317-6328. [5] 曹启纯, 刘向军. 直动式双断点继电器不平衡燃弧现象研究[J]. 电器与能效管理技术, 2018(24): 7-12. Cao Qichun, Liu Xiangjun.Study on unbalanced arcing phenomena in direct-motion double-break relay[J]. Electrical & Energy Management Tech-nology, 2018(24): 7-12. [6] 耿云, 姚晓飞, 许闽榉, 等. 双断口真空断路器高频涌流预击穿特性实验[J]. 电工技术学报, 2026, 41(10): 3465-3481. Geng Yun, Yao Xiaofei, Xu Minju, et al.High-frequency inrush current prestrike characteristics of double-break vacuum circuit breakers[J]. Trans-actions of China Electrotechnical Society, 2026, 41(10): 3465-3481. [7] Hou Guobin, Zhang Dandan, Li Zhenbiao, et al.Study on magnetically blown arc characteristics and the resulting contact erosion mechanisms of high-power DC relays[J]. Journal of Physics D: Applied Physics, 2023, 56(21): 215201. [8] 董华军, 程靖洲, 赵一鉴, 等. 大电流真空电弧开断过程瞬态特性仿真分析[J]. 电机与控制学报, 2024, 28(1): 189-196. Dong Huajun, Cheng Jingzhou, Zhao Yijian, et al.Simulation analysis on transient characteristics of high-current vacuum arc in process of interruption[J]. Electric Machines and Control, 2024, 28(1): 189-196. [9] Zhou Xue, Zhou Yuxin, Li Donghui, et al.Suppression of swirl arc re-strike under magnetic blowing for DC high-power application[J]. IEEE Access, 2023, 11: 140418-140427. [10] 马飞越, 姚晓飞, 刘志远, 等. 2/3匝线圈式纵磁触头大开距真空断路器分闸速度设计[J]. 电工技术学报, 2024, 39(13): 4139-4152. Ma Feiyue, Yao Xiaofei, Liu Zhiyuan, et al.Design of opening velocities for large-gap vacuum circuit breakers with 2/3 coil-type axial magnetic field contacts[J]. Transactions of China Electrotechnical Society, 2024, 39(13): 4139-4152. [11] 李静, 郭沛鑫, 彭世东, 等. 基于改进结构的自激式直流空气断路器小电流开断能力提升方法[J]. 电工技术学报, 2024, 39(22): 7278-7290. Li Jing, Guo Peixin, Peng Shidong, et al.Enhance small current breaking performance of self-excited DC air circuit breaker based on an improved structure[J]. Transactions of China Electrotechnical Society, 2024, 39(22): 7278-7290. [12] 李静, 张龙豪, 段薇, 等. 多场耦合下栅片特性对直流空气电弧开断性能影响[J]. 电工技术学报, 2026, 41(16): 5651-5662. Li Jing, Zhang Longhao, Duan Wei, et al.Investi-gating the influence of splitter characteristics on DC air arc interruption in a multi-physics coupling environment[J]. Transactions of China Electrotech-nical Society, 2026, 41(16): 5651-5662. [13] 李静, 钱宇, 王奥飞, 等. 磁吹直流空气断路器弧根跃迁及对开断特性的影响研究[J]. 中国电机工程学报, 2023, 43(4): 1651-1660 3. Li Jing, Qian Yu, Wang Aofei, et al.Research on arc root transition of magnetic DC air circuit breaker and its influence on breaking characteristics[J]. Pro-ceedings of the CSEE, 2023, 43(4): 1651-1660. [14] Hou Guobin, Zhang Dandan, Li Zhenbiao, et al.Study on the influence of transverse magnetic field on the arc and reignition characteristics of HVDC relays[J]. Journal of Physics D: Applied Physics, 2024, 57(38): 385207. [15] 武稼祥, 于丽琴, 常东旭, 等. 耦合磁吹和触头运动的直流接触器电弧特性研究[J]. 高压电器, 2024, 60(9): 212-220. Wu Jiaxiang, Yu Liqin, Chang Dongxu, et al.Study on DC contactor arc characteristics coupled with magnetic field and contact motion[J]. High Voltage Apparatus, 2024, 60(9): 212-220. [16] 王海波, 邹海荣, 龚祚勇, 等. 三维无极性直流接触器电弧模型[J]. 上海电机学院学报, 2024, 27(6): 351-355, 361. Wang Haibo, Zou Hairong, Gong Zuoyong, et al.Research on arc model of three-dimensional non-polarity DC contactor[J]. Journal of Shanghai Dianji University, 2024, 27(6): 351-355, 361. [17] Huang Keyao, Sun Hao, Niu Chunping, et al.Simulation of arcs for DC relay considering different impacts[J]. Plasma Science and Technology, 2020, 22(2): 024003. [18] 任万滨, 何育斌, 郑哲. 具有触桥结构的大功率电磁继电器电寿命分析[J]. 电工材料, 2022(2): 3-5, 10. Ren Wanbin, He Yubin, Zheng Zhe.Electrical lifetime analysis of high-power electromagnetic relay with double contact bridges[J]. Electrical Engineering Materials, 2022(2): 3-5, 10. [19] Zheng Zhe, Zhang Chao, Ren Wanbin.Failure analysis of power relays with multiple breaks in the electrical endurance experiments[J]. IEEE Trans-actions on Components, Packaging and Manufa-cturing Technology, 2022, 12(8): 1311-1317. [20] 巴·马科斯尔. 双触桥结构继电器电寿命的试验研究[D]. 哈尔滨: 哈尔滨工业大学, 2021. Ba Marcos.Experimental study on electric life of the electromagnetic relay with double contact bridge[D]. Harbin: Harbin Institute of Technology, 2021. [21] 王朝. 非平衡分断燃弧下的双桥式直流接触器电寿命研究[D]. 大连: 大连理工大学, 2024. Wang Chao.Research on the electrical life of DC contactor with double contact bridge under unbalanced break arcing[D]. Dalian: Dalian University of Tech-nology, 2024. [22] Wang Gongrun, Dong Enyuan, Wang Yongxing, et al.Investigation on arc asynchronous characteristics of the double bridge-type contacts in DC relays[J]. IEEE Transactions on Plasma Science, 2023, 51(2): 572-580. [23] 刘亚奇. 桥式触头分断电弧特性实验研究[D]. 哈尔滨: 哈尔滨工业大学, 2013. Liu Yaqi.Research on breaking arc characteristics of bridge-type contact[D]. Harbin: Harbin Institute of Technology, 2013. [24] Clegg A G, Coulson I M, Hilton G, et al.The temperature stability of NdFeB and NdFeBCo mag-nets[J]. IEEE Transactions on Magnetics, 1990, 26(5): 1942-1944. [25] 刘向军, 林臻, 林琼, 等. 永磁体磁场作用下高压直流继电器电弧重燃及抑制方法研究[J]. 中国电机工程学报, 2025, 45(20): 8255-8266. Liu Xiangjun, Lin Zhen, Lin Qiong, et al.Arc reignition and suppression for high-voltage DC relay under influence of permanent magnet magnetic field[J]. Proceedings of the CSEE, 2025, 45(20): 8255-8266. [26] Bo Kai, Zhou Xue, Zhai Guofu.Investigation on arc dwell and restriking characteristics in DC high-power relay[J]. IEEE Transactions on Plasma Science, 2017, 45(6): 1032-1042. [27] 兰太寿, 李炜荣, 刘向军. 基于虚拟双目视觉的电器电磁机构三维动态测试研究[J]. 电子测量与仪器学报, 2014, 28(1): 29-35. Lan Taishou, Li Weirong, Liu Xiangjun.Three-dimensional dynamic test research for electro-magnetic mechanism of electrical apparatus based on virtual binocular vision[J]. Journal of Electronic Measurement and Instrumentation, 2014, 28(1): 29-35. |
|
|
|