Operation and Control on the Grid-Side Converter of the Directly-Driven Wind Turbine With PM Synchronous Generator During Asymmetrical Faults |
Huang Shoudao, Xiao Lei, Huang Keyuan, Chen Ziqiang, Xiong Shan |
Hunan University Changsha 410082 China |
|
|
Abstract Fluctuation mechanism on DC voltage of converter and stability control strategy in order to improve the capability of faults ride through were studied when asymmetry faults took place. By the introduction of proportional-integral-resonant controller to grid-side converter, and steady-state non-poor regulation for positive and negative sequence current in the positive-sequence synchronous rotating frame, a new control algorithm was proposed to eliminate the quadratic fluctuations of DC voltage caused by the negative-sequence current out of control, and maintain the wind turbine stable. Simulation and experimental results show that the proposed control algorithm can effectively control positive and negative-sequence currents in the positive-sequence synchronous rotating frame, and eliminate the DC voltage fluctuation.
|
Received: 14 May 2010
Published: 07 March 2014
|
|
|
|
|
[1] 张春晖. 大型风电设备发展的新方向—定子超高压转子永磁化[J]. 电器工业, 2007(7): 48-50. [2] Mukhtiar Singh, Ambrish Chandra, et al. Power maximization and voltage sag/swell ride-through capability of PMSG based variable speed wind energy conversion system[C]. 34th Annual Conference of IEEE on Industrial Electronics, 2008: 2206-2211. [3] Marius Fatu, Cristian Lascu, Gheorghe Daniel Andreescu, et al. Voltage sags ride-through of motion sensorless controlled PMSG for wind turbines[C]. IEEE Industry Applications Conference, 42nd IAS Annual Meeting, 2007: 171-178. [4] Vincenti D, Jin H. A three phase regulated PWM rectifier using direct on-line feed forward input unbalance correction control[C]. Electrical and Computer Engineering Conference, 1993: 72-75. [5] Song H S, Joo I W, Nam K. Source voltage sensorless estimation scheme for PWM rectifiers under unbalanced conditions[J]. IEEE Transactions on Inductry Electron., 2003, 50(6): 1238-1245. [6] Yin B, Oruganti R, Panda S K, et al, An output-power-control strategy for a three-phase PWM rectifier under unbalanced supply conditions[J]. IEEE Transactions on Inductry Electron., 2008, 55(5): 2140-2151. [7] 徐金榜, 何顶新, 赵金, 等. 电压不平衡情况下PWM整流器功率分析方法[J]. 中国电机工程学报, 2006, 26(16): 80-85. [8] Xiaoming Yuan, Jost Allmeling, Willi Merk, et al. Stationary frame generalized integrators for current control of active power filters with zero steady state error for current harmonics of concern under unbalanced and distorted operation conditions[J]. IEEE Transactions on Industry Applications, 2002, 38(2): 2134-2150. [9] Zmood D N, Holmes D G, Bode G. Frequency domain analysis of three phase linear current regulators[C]. IEEE Industry Applications Conference, 34th IAS Annual Meeting, 1999: 818-825. [10] Zmood D N, Holmes D G. Stationary frame current regulation of PWM inverters with zero steady-state error[J]. IEEE Transactions on Power Electronics, 2003, 18(2): 814-822. [11] Teodorescu R, Blaabjerg F, Borup U, et al. A new control structure for grid-connected LCL PV inverters with zero steady-state error and selective harmonic compensation[C]. Nineteenth Annual IEEE, on Applied Power Electronics Conference and Exposition, 2004: 580-586. [12] Hu Jiabing, He Yikang, Multi-frequency proportional- resonant(MFPR) current controller for PWM VSC under unbalanced supply conditions[J]. Journal of Zhe Jiang University Science A, 2007, 8(10): 1527- 1531. [13] Marco Liserre, Remus Teodorescu, Frede Blaabjerg. Multiple harmonics control for three-phase grid converter systems with the use of PI-RES current controller in a rotating frame[J]. IEEE Transactions on Power Electronics, 2006, 21(3): 836-841. [14] 梁亮, 李建林, 赵斌, 等. 适合于风力发电系统的电压跌落发生器[J]. 可再生能源, 2007, 25(3): 64-68. |
|
|
|