Abstract:Within nowadays substations, static var compensator (SVC) devices are being realized to achieve high flexibility and wide tolerance to load variation. However, due to frequent switching of the thyristors, large amount of broadband electromagnetic emissions are being generated, which results in electromagnetic contamination to both the power grids and the victim electronic devices positioned nearby. Based on optical fiber, circuit and field transducers, an advanced acquisition system is established to implement on-site measurements of the electromagnetic interference (EMI). Based on the corrected measurement data, the switching bursts of the radiated EMI data within a power cycle are analyzed to give the frequency and amplitude range of the radiated interferences. Further, with utilization of time-frequency analysis techniques, a feature extraction methodology for electromagnetic emissions based on time-frequency analysis is established, and more detailed and useful information of the SVC-based electromagnetic environment can be obtained through 2-D and 3-D display, which presents fundamental reference for characterizing the SVC-based interfering mechanisms and effectively evaluating the electromagnetic environment.
张黎, 李庆民, 王伟, Siew W. H.. 静态无功补偿器电磁辐射干扰的测量与特征提取方法[J]. 电工技术学报, 2010, 25(12): 8-15.
Zhang Li, Li Qingmin, Wang Wei, Siew W. H.. Measurement and Feature Extraction of the Radiated Emissions Generated by a Static Var Compensator. Transactions of China Electrotechnical Society, 2010, 25(12): 8-15.
[1] Edris A. FACTS technology development: an update[J]. Power Engineering Review, 2000, 20(3): 4-9.
[2] Tihanyi Laszio. Electromagnetic compatibility in power electronics[M]. New York: IEEE Press, 1995.
[3] 纪勇, 李向荣. 基于GTO的±20Mvar STATCOM的现场运行及改进[J]. 电力系统自动化, 2003, 7(4): 61-65.
[4] Siew W H, Li Qingmin, Stewart M. Measurement of electromagnetic emissions from FACTS equipment operational within substations—Part I [J]. IEEE Transactions on Power Delivery, 2005, 20(2): 1-7.
[5] Stewart M, Siew W H, Li Qingmin. Conducted emissions rrom FACTS equipment operational within substations—Part II [J]. IEEE Transactions on Power Delivery, 2005, 20(2): 8-13.
[6] Li Qingmin, Siew W H, Stewart M. Radiated emissions from FACTS equipment operational within substations—Part II [J]. IEEE Transactions on Power Delivery, 2005, 20(2): 14-22.
[7] 徐政. 基于晶闸管的柔性交流输电控制装置[M]. 北京: 机械工业出版社, 2005.
[8] 陈淑凤, 马蔚宇, 马晓庆. 电磁兼容试验技术[M]. 北京: 北京邮电大学出版社, 2001.
[9] Gustavsen B, Semlyen A. Combined phase and modal domain calculation of transmission line transients based on vector fitting[J]. IEEE Transactions on Power Delivery, 1998, 13(2): 596-604.
[10] Gustavsen B, Semlyen A. Application of vector fitting to state equation representation of transformers for simulation of electromagnetic transients[J]. IEEE Transactions on Power Delivery, 2004, 19(3): 952-956.
[11] Wouter H, Tom D. A discussion of rational approximation of frequency domain responses by vector fitting[J]. IEEE Transactions on Power Delivery, 2006, 21(1): 441-443.
[12] 张重远, 梁贵书, 崔翔. GIS电站内传导干扰计算模型的建立[J]. 高压电器, 2003, 39(4): 11-13.
[13] 张重远, 梁贵书, 崔翔. 气体绝缘变电站内PT的特快速暂态仿真建模[J]. 中国电机工程学报, 2003, 23(7): 84-87.
[14] 张重远, 梁贵书, 崔翔. 气体绝缘变电站内电压互感器高频传输函数模型的建立[J]. 电工技术杂志, 2002, 21(12): 26-28.
[15] 张黎, 李庆民, 王伟, 等. 用于传递函数参数辨识的改进复向量拟合法[J]. 高电压技术, 2008, 34(8): 1542-1546.
[16] 胡广书. 数字信号处理[M]. 北京: 清华大学出版社, 2002.
[17] 袁鹏, 司文荣, 李军浩, 等. 局部放电脉冲的Wigner时频分布特性研究[J]. 高压电器, 2008, 44(6): 524-526.