Abstract:Based on the vector resonant regulator,this paper proposes a novel PAPF closed-loop scheme with source current detection.The novel scheme does not need the harmonics extraction algorithm and treats the PAPF as an equivalent band stop filter between the nonlinear load and the power source,which could realize better harmonics filtering performance in a reasonable way.
易皓, 卓放, 翟灏. 基于矢量谐振调节器的有源电力滤波器网侧电流检测控制方法研究[J]. 电工技术学报, 2015, 30(7): 72-79.
Yi Hao, Zhuo Fang, Zhai Hao. Research on Source Current Detection Type APF Control Scheme Based on Vector Resonant Regulator. Transactions of China Electrotechnical Society, 2015, 30(7): 72-79.
[1] Zhong C,Yingpeng L,Miao C.Control and performance of a cascaded shunt active power filter for aircraft electric power system[J].IEEE Transactions on Industrial Electronics,2012,59(9):3614-3623. [2] Mattavelli P.A closed-loop selective harmonic compensation for active filters[J].IEEE Transactions on Industry Applications,2001,37(1):81-89. [3] Mariethoz S,Rufer A C.Open loop and closed loop spectral frequency active filtering[J].IEEE Transactions on Power Electronics,2002,17(4):564-573. [4] Sun Xiaofeng,Li Ningning,Wang Baocheng,et al.Improvement for the closed-loop control of shunt Active Power Filter[C].IEEE 6th International Power Electronics and Motion Control Conference,Wuhan,China,2009:2371-2376. [5] Ohnishi T,Ueki K,Hojo M.Stable control method of source current detection type active filter by voltage harmonics feedback[C].European Conference on Power Electronics and Applications,Dresden,Germany,2005:1-9. [6] de Araujo Ribeiro R L,de Azevedo C C,de Sousa R M.A robust adaptive control strategy of active power filters for power-factor correction,harmonic compensation,and balancing of nonlinear loads[J].IEEE Transactions on Power Electronics,2012,27(2):718-730. [7] Miret J,Castilla M,Matas J,et al.Selective harmonic-compensation control for single-phase active power filter with high harmonic rejection[J].IEEE Transactions on Industrial Electronics,2009,56(8):3117-3127. [8] Zmood D N,Holmes D G,Bode G H.Frequency-domain analysis of three-phase linear current regulators[J].IEEE Transactions on Industry Applications,2001,37(2):601-610. [9] Zmood D N,Holmes D G.Stationary frame current regulation of PWM inverters with zero steady-state error[J].IEEE Transactions on Power Electronics,2003,18(3):814-822. [10]杨秋霞,梁雄国,郭小强,等.准谐振控制器在有源电力滤波器中的应用[J].中国电机工程学报,2009,24(7):171-176. Yang Qiuxia,Liang Xiongguo,Guo Xiaoqiang,et al.Application of quasi resonant controller for active power filter[J].Proceedings of the CSEE,2009,24(7):171-176. [11]Yi H,Zhuo F,Li Y,et al.Comparison analysis of resonant controllers for current regulation of selective active power filter with mixed current reference[J].Journal of Power Electronics,2013,13(5):861-876. [12]Bojoi R,Limongi L,Profumo F,et al.Analysis of current controllers for active power filters using selective harmonic compensation schemes[J].IEEJ Transactions on Electrical and Electronic Engineering,2009,4(2):139-157. [13]Lascu C,Asiminoaei L,Boldea I,et al.Frequency response analysis of current controllers for selective harmonic compensation inactive power filters[J].IEEE Transactions on Industrial Electronics,2009,56(2):337-347. [14]黄如海,谢少军.基于比例谐振调节器的逆变器双环控制策略研究[J].电工技术学报,2012,27(2):77-81. Huang Ruhai,Xie Shaojun.Double-loop digital control strategy based on proportional-resonant controller[J].Transactions of China Electrotechnical Society,2012,27(2):77-81. [15]王剑,郑琼林,高吉磊.基于根轨迹法的单相PWM整流器比例谐振电流调节器设计[J].电工技术学报,2012,27(9):251-256. Wang Jian,Zheng Qionglin,Gao Jilei.Design of current proportional-resonant regulator for single phase PWM rectifier based on root-locus method[J].Transactions of China Electrotechnical Society,2012,27(9):251-256. [16]章玮,王宏胜,任远,等.不对称电网电压条件下三相并网型逆变器的控制[J].电工技术学报,2010,25(12):103-110. Zhang Wei,Wang Hongsheng,Ren Yuan,et al.Investigation on control of three-phase grid-connected inverters under unbalanced grid voltage conditions[J].Transactions of China Electrotechnical Society,2010,25(12):103-110. [17]Trinh Q N,Lee H H.An Advanced current control strategy for three-phase shunt active power filters[J].IEEE Transactions on Industrial Electronics,2013,60(12):5400-5410. [18]Lascu C,Asiminoaei L,Boldea I,et al.High performance cur L rent controller for selective harmonic compensation in active power filters[J].IEEE Transactions Power Electron,2007,27(5):1826-1835.