Discharge Current Measurement of Pulsed High Magnetic Field Facility Based on PCB Air-Core Coil and Digital Integrator
Han Xiaotao1, 2, Huang Lantao1, 2, Sun Wenwen1, 2, Ding Pengcheng1, 2, Xie Jianfeng1, 2, Shi Jiangtao1, 2
1. Wuhan National High Magnetic Field Center, Huazhong University of Science and Technology Wuhan 430074 China 2. State Key Laboratory of Advanced Electromagnetic Engineering and Technology Huazhong University of Science and Technology Wuhan 430074 China
Abstract:In order to monitor discharging process of the pulsed high magnetic facility, the discharge current must be measured accurately. In this paper, the two stages of discharge and the characteristics of the discharge current are analyzed in details by simulation. According to the characteristics of the discharge current and the fundamental principle of air-core coil, a measurement scenario of combination printed circuit board (PCB) air-core coil and digital integrator based on improved Al-Alaoui algorithm is put forward. A calibration system using Pearson 4427 current transformer is designed and tested. These tests verify the accuracy and the stability of the scenario can meet the measurement requirement of pulsed high current.
韩小涛, 黄澜涛, 孙文文, 丁鹏程, 谢剑锋, 施江涛. 基于PCB空心线圈和数字积分器的脉冲强磁场装置放电电流测量[J]. 电工技术学报, 2012, 27(12): 13-19.
Han Xiaotao, Huang Lantao, Sun Wenwen, Ding Pengcheng, Xie Jianfeng, Shi Jiangtao. Discharge Current Measurement of Pulsed High Magnetic Field Facility Based on PCB Air-Core Coil and Digital Integrator. Transactions of China Electrotechnical Society, 2012, 27(12): 13-19.
[1] Herlach F, Miura N. High magnetic fields: science and technology[M]. Singapore: World Scientific Publishing Co., Pte., Ltd., 2003. [2] Li Liang, Ding Hongfa, Peng Tao, et al. The pulsed high magnetic field facility at HUST, Wuhan, China and associated magnets[J]. IEEE Transactions on Applied Superconductivity, 2008, 18(2): 596-599. [3] 揭秉信. 大电流测量[M]. 北京: 机械工业出版社, 1987. [4] Locci Nicola, Muscas Carlo. Comparative analysis between active and passive current transducers in sinusoidal and distorted conditions[J]. IEEE Transactions on Instrumentation and Measurement, 2001, 50(1): 123-128. [5] Dupraz J P, Alain Fanget, Wolfgang Grieshaber, et al. Rogowski coil: exceptional current measurement tool for almost any application[C]. Proceedings of the IEEE Power Engineering Society General Meeting, Tampa , 2007, 6: 3768-3775. [6] Ray W F, Hewson C R. High performance rogowski current transducers[C]. Proceedings of the 2000 IEEE Industry Applications Society 35th IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy, Roma, 2000, 10: 3083-3090. [7] Han Xiaotao, Xie Jianfeng, Song Zhiwei. et al. Design and realization of the control and measurement system of the Wuhan pulsed high magnetic field facility[J]. Journal of Low Temperature Physics, 2010, 159 (1-2): 345-348. [8] 王程远, 陈幼平, 张冈, 等. PCB空心线圈位置误差分析与控制[J]. 中国电机工程学报, 2008, 28(15): 103-108. Wang Chengyuan, Cheng Youping, Zhang Gang, et al. Analysis and control on the position errors of PCB air-core coils[J]. Proceedings of CSEE. 2008, 28(15): 103-108. [9] 陈辉, 陈卫, 李伟基. Rogowski线圈的数字积分器仿真及研究[J]. 电力系统保护与控制, 2009, 37(2): 43-47. Chen Hui, Chen Wei, Li Weiji. The simulation and research based on the digital integrator of the Rogowski coil[J]. Power System Protection and Control, 2009, 37(2): 43-47. [10] 张可畏, 王宁, 段雄英, 等. 用于电子式电流互感器的数字积分器[J]. 中国电机工程学报, 2004, 24(12): 104-107. Zhang Kewei, Wang Ning, Duan Xiongying, et al. A digital integrator for electronic current transducer[J]. Proceedings of CSEE, 2004, 24(12): 104-107. [11] AI-Alaoui M A. Novel digital integrator and differentiator[J]. Electronic Letters, 1993, 29(4): 376-378. [12] AI-Alaoui M A. Using fractional delay to control the magnitudes and phases of integrators and differentiators[J]. IET Signal Processing, 2007, 1(2): 107-119. [13] IEC 61000—4—5 Electromagnetic compatibility(EMC)—Part 4—5: Testing and measurement techniques- surge immunity test[S].