Analysis of Three-Phase Grid-Connected Inverter Proportional Resonant Control and Grid Voltage Feed-Forward
Ma Lin1, 2, Jin Xinmin1, Tang Fen1, Pedro Rodriguez2, Sun Kai3
1. School of Electrical Engineering Beijing Jiaotong University Beijing 100044 China 2. Universitat Politècnica de Catalunya Barcelona 08222 Spain 3. State Key Lab of Power Systems Tsinghua University Beijing 100084 China
Abstract:Nowadays, all kinds of distributed generation (DG) systems are developed rapidly. Grid connected inverter as one of the most important parts in the DG system, its controller are always the investigated focus. In order to improve the connected current and the response of the controller, stationary reference frame control strategy with proportional resonant (PR) controller due to its high dynamic and good harmonic compensation performance characteristics is widely used in many different DG applications. This paper proposes a new additional proportional resonant control method with positive sequence grid voltage feed-forward. By using this method, both the quality of grid connected current and the dynamic performance are improved, which also validated by experiments.
马琳, 金新民, 唐芬, PedroRodriguez, 孙凯. 三相并网逆变器比例谐振控制及其网压前馈问题分析[J]. 电工技术学报, 2012, 27(8): 56-63.
Ma Lin, Jin Xinmin, Tang Fen, Pedro Rodriguez, Sun Kai. Analysis of Three-Phase Grid-Connected Inverter Proportional Resonant Control and Grid Voltage Feed-Forward. Transactions of China Electrotechnical Society, 2012, 27(8): 56-63.
[1] 周德佳, 赵争鸣, 袁立强, 等. 300kW光伏并网系统优化控制与稳定性分析[J]. 电工技术学报, 2008, 23(11): 116-122. Zhou Dejia, Zhao Zhengming, Yuan Liqiang, et al. Optimum control and tability stability analysis analysis for a 300kW photovoltaic gridgrid-connected connected system[J]. Transactions of China Electrotechnical Society, 2008, 23(11): 116-122. [2] Lin Ma, Xinmin Jin, Kerekes, et al. The PWM strategies of grid-connected distributed generation active NPC inverters[C]. Energy Conversion Congress and Exposition, 2009, 9: 920-927. [3] Blaabjerg F, Teodorescu R, Liserre M, et al. Overview of control and grid synchronization for distributed power generation systems[J]. IEEE Transactions on Industrial Electronics, 2006, 53(5): 1398-1409. [4] 马琳, 金新民, 唐芬, 等. 小功率单相并网逆变器并网电流的比例谐振控制[J]. 北京交通大学学报, 2010, 34(2): 118-133. Ma Lin, Jin Xinmin, Tang Fen, et al. Proportional- resonant gird-connected current control of low power single phase inverte[J]. Journal of Beijing Jiaotong University, 2010, 34(2): 118-133. [5] Teodorescu R, Blaabjerg F, Borup U, et al. A new control structure for grid-connected LCL PV inverters with zero steady-state error and selective harmonic compensation[C]. IEEE Applied Power Electronics Conference, and Exposition, 2004, 1: 580-586. [6] 陈炜, 陈成, 宋战锋, 等. 双馈风力发电系统双PWM变换器比例谐振控制[J]. 中国电机工程学报, 2009, 29(15): 1-7. Chen Wei, Chen Cheng, Song Zhanfeng, et al. Proportional-resonant control for dual PWM converter in doubly fed wind generation system[J]. Proceedings of the CSEE, 2009, 29(15): 1-7. [7] Bhowmik S, Spee R, Enslin J H R.Performance optimization for doubly fed wind power generation systems[J]. IEEE Transactions on Industry Applications, 1999, 35(4): 949-958. [8] Petersson A, Harnefors L, Thiringer T.Evaluation of current control methods for wind turbines using doubly-fed induction machines[J].IEEE Transactions on Power Electronics, 2005, 20(1): 227-235. [9] Teodorescu R, Blaabjerg F, Liserre M, et al. Proportional-resonant controllers and filters for grid-connected voltage-source converters[J]. IEE Proceedings of Electric Power Applications, 2006, 153(5): 750-762. [10] Mattavelli P. A closed-loop selective harmonic compensation for active filters[J]. IEEE Transactions on Industrial Applications, 2001, 37(1): 81-89. [11] Zmood D N, Holmes D G.Stationary frame cruuent regulation of PWM inverters with zero steady-state error[J].IEEE Transactions on Power Electronics, 2003, 18(3): 814-822. [12] Hasanzadeh A, Onar O C, Mokhtari H, et al. A proportional-resonant controller-based wireless control strategy with a reduced number of sensors for parallel-operated UPSs[J]. IEEE Transactions on Power Delivery, 2010, 25(1): 468-478. [13] Yuan X, Merk W, Stemmler H, et al. Stationary-frame generalized integrators for current control of active power filters with zero steady-state error for current harmonics of concern under unbalanced and distorted operating conditions[J]. IEEE Transactions on Industrial Applications, 2002, 38(2): 523-532. [14] Shuitao Yang, Qin Lei, Peng F Z, et al. A robust control scheme for grid-connected voltage source inverters[C]. Applied Power Electronics Conference and Exposition, 2010 Twenty-Fifth Annual IEEE, 2010: 1002-1009. [15] Rodriguez P, Teodorescu R, Candela I, et al. New positive-sequence voltage detector for grid synchronization of power converters under faulty grid conditions[C]. IEEE Power Electronics Specialists Conference, 2006, 37: 1-7.