Abstract:The geometry of a Halbach magnet is ideal for use as a magnetic field source in a table-top nuclear magnetic resonance (NMR) spectrometer. But the magnetic field of an unmodified Halbach magnet is not sufficiently homogeneous to allow observation of a nuclear magnetic resonance signal. In this paper, the saddle coils, which are used in the superconducting magnet, are introduced into the shimming of Halbach magnet. For the development of high resolution table-top NMR spectrometer, the special cylinder shim coils comprised of saddle coils are designed to improve the homogeneity of the transverse magnetic field of Halbach magnet.
[1] Kumada M, Fujisawa T, Hirao Y. Development of a model 4 tesla diple magnet[C]. Proceedings of the Second Asian Partical Accelerator Conference, 2001: 840-842. [2] Robert M Pearson, John G Pearson. Halbach dipole magnet shim system. US 2002/0179830 A1[P]. [3] Zhang Xiaofeng, Venu Mahesh, David Ng. Design construction and NMR testing of a 1 tesla halbach permanent magnet for magnetic resonance[C]. Excerpt from the Proceedings of the COMSOL Users Conference 2005. [4] Chen Jizhong, Xu Chunyan. An improved discrete configuration of a cylinder magnet for portable nuclear magnetic resonance instruments[J]. Journal of Applied Physics, 2007, 101: 123926. [5] Halbach K. Design of permanent multipole magnets with oriented rare earth cobalt materials[J]. Nucl. Instr. Meth., 1980, 169(1): 1-10. [6] Sauzade M D, Kan S K. High resolution nuclear magnetic resonance spectroscopy in high magnetic fields[J]. Advances in Electronics and Electron Physics, 1973, 34: 1-92. [7] Romeo F, Hoult L I. Magnet field profiling: analysis and correcting coil design[J]. Magnetic Resonance in Medicine, 1984, 1:44-65. [8] Bobrov E S, Punchard W F B. A general method of design of axial and radial shim coils for NMR and MRI magnets[J]. IEEE Transactions on Magnetics, 1988, 24(1): 533-536. [9] Dorri Bizhan, Benesch F. Method of optimizing shim coil current selection in magnetic resonance magnetics: US 5006804[P]. [10] Jan Chládek, Pavel Konzbul, Pavel smera, et al. Evolutionary and genetic optimization of NMR gradient and shim coils[J]. IEEE Transactions on Magnetics, 2000, 36(4): 1102-1105. [11] Crozier S, Doddrell D M. Gradient-coil design by simulated annealing[J]. J. Magn. Reson., 1993, 103(3): 354-357. [12] Michael A Brideson, Larry K Forbes, Stuart Crozier. Determining complicated winding patterns for shim coils using stream functions and the target-field method[J]. Concepts in Magnetic Resonance, 2002, 14(1): 9-18. [13] Larry K Forbes, Michael A Brideson, Stuart Crozier. A target-field method to design circular biplanar coils for asymmetric shim and gradient fields[J]. IEEE Transactions on Magnetics, 2005, 41(6): 2134-2144. [14] Anderson W A. Apparatus for improving the homogeneity of a magnetic field. US3469180[P]. [15] 赵微, 刘志文, 刘勇, 等. 开放式低场永磁MRI磁体的匀场方法研究[J]. 电工电能新技术, 2007, 26(3):29-32. [16] 夏平畴. 永磁机构[M]. 北京:北京工业大学出版社, 2000. [17] Jin Jianming. Electromagnetic analysis and design in magnetic resonance imaging[M]. New York: CRC Press, 1999. [18] 俎栋林. 电动力学[M]. 北京:清华大学出版社, 2006.