Abstract:Sheds configuration of composite insulators is one of the main factors affecting the icing flashover voltage, and thus it is imperative to optimal the sheds configuration in order to ensure the safe operation of composite insulators at icing areas. Simulating the natural icing conditions in the artificial climate chamber, this paper studies the icing and flashover characteristics of composite insulators energized with the maximum working voltage. The results show: the icing quality of composite insulators has something to do with the sheds configuration characteristics, leakage distance, freezing water conductivity, etc. In other words, with the increase of the leakage distance and the ratio of leakage distance and the arc distance(CF coefficient), the ice coating on the insulators become more serious and the flashover voltage drops notably. As the influence law of the leakage and the CF coefficient on the icing and the flashover voltage of composite insulators is complex, several new characteristic parameters characterizing the sheds configuration of composite insulators are proposed in this paper, By optimizing the new parameters, the best sheds configuration of composite insulators adapted to severe icing districts could be found.
[1] 蒋兴良, 舒立春, 孙才新. 电力系统污秽与覆冰绝缘[M]. 北京: 中国电力出版社, 2009. [2] 谢从珍. 硅橡胶绝缘子伞裙优化研究[D]. 广州: 华南理工大学, 2010. [3] 张锐, 吴光亚. 高压输电线路绝缘子行业发展和技术综述[J]. 电力技术, 2009, 72(2): 47-53. Zhang Rui, Wu Guangya. Development and technical review of the high-voltage transmission line insulator industry[J]. Electric Power Standardization, 2009, 72(2): 47-53. [4] 蒋兴良, 张志劲, 等. 高海拔下不同伞形结构750kV合成绝缘子短样交流污秽闪络特性及其比较[J]. 中国电机工程学报, 2005, 25(12): 159-164. Jiang Xingliang, Zhang Zhijin, et al. AC pollution flashover performance and comparison of short samples of 750kv composite insulators with different configuration in high altitude area[J]. Proceedings of the CSEE, 2005, 25(12): 159-164. [5] 王波. 伞裙结构对复合绝缘子直流冰闪特性影响的研究[D]. 重庆: 重庆大学, 2007. [6] 欧阳丽莎, 黄新波, 李俊峰, 等. 1 000kV特高压输电线路覆冰区的研究与划分[J]. 高压电器, 2010, 46(5): 4-8, 13. Ouyang Lisha, Huang Xinbo, Li Junfeng, et al. Research and division of icing area along 1 000kV ultra high voltage AC transmission lines[J]. High Voltage Apparatus, 2010, 46(5): 4-8, 13. [7] 王绍武. 污秽地区有机外绝缘特性的研究[D]. 北京: 清华大学, 2001. [8] 袁前飞, 舒立春, 蒋兴良, 等. 低气压下不同伞裙结构复合绝缘子交流污闪性能对比[J]. 高电压技术, 2010, 36(7): 1662-1668. Yuan Qianfei, Shu Lichun, Jiang Xingliang, et al. Comparison of AC pollution flashover performances for composite insulators with different configuration under low atmospheric pressure[J]. High Voltage Engineering, 2010, 36(7): 1662-1668. [9] 蒋兴良, 巢亚峰, 陈凌, 等. 高海拔地区不同伞裙结构复合绝缘子短样直流冰闪性能对比[J]. 高电压技术, 2011, 37(5): 1066-1073. Jiang Xingliang, Chao Yafeng, Chen Ling, et al. Comparison of DC icing flashover performances for pre-polluted short samples of composite insulators with different configuration in high altitude area[J]. High Voltage Engineering, 2011, 37(5): 1066-1073. [10] 杨庆. 绝缘子沿面电场特性和放电模型研究[D]. 重庆: 重庆大学, 2006. [11] 温作铭. 基于流体力学的覆冰地区用复合绝缘子伞裙结构研究[D]. 重庆: 重庆大学, 2007. [12] 舒立春, 蒋兴良, 田玉春, 等. 海拔4 000m以上地区4种合成绝缘子覆冰交流闪络特性及电压校正[J]. 中国电机工程学报, 2004, 24(1): 97-101. Shu Lichun, Jiang Xingliang, Tian Yuchun, et al. AC flashover performance and voltage correction of four types of iced composite insulator at altitude 4000m above[J]. Proceedings of the CSEE, 2004, 24(1): 97-101. [13] 黄斌. 交流电场对复合绝缘子覆冰过程及放电特性影响的研究[D]. 重庆: 重庆大学, 2008. [14] International Electrotechnical Commission. International standard IEC 60507 Artificial pollution tests on high voltage insulators to be used on AC systems[S]. 1991. [15] 张志劲, 蒋兴良, 马俊, 等. 工作电压下110kV交流绝缘子串覆冰特性研究[J]. 中国电机工程学报, 2006, 26(4): 140-143. Zhang Zhijin, Jiang Xingliang, Ma Jun, et al. Study on icing performance of 110kV insulator strings at AC service voltage[J]. Proceedings of the CSEE, 2006, 26(4): 40-143. [16] 马俊, 蒋兴良, 张志劲, 等. 带电覆冰过程对盘型悬式绝缘子覆冰及电场特性的影响[J]. 高电压技术, 2010, 36(8): 1936-1941. Ma Jun, Jiang Xingliang, Zhang Zhijin, et al. Influence of the icing period with voltage on the icing and electric field characteristics of impendent insulators[J]. High Voltage Engineering, 2010, 36(8): 1936-1941. [17] 张志劲, 蒋兴良, 胡建林, 等. 间插布置方式对交流绝缘子串覆冰特性影响[J]. 电工技术学报, 2011, 26(1): 170-176. Zhang Zhijin, Jiang Xingliang, Hu Jianlin, et al. Influence of the type of insulators connected with alternately large and small diameter sheds on AC icing flashover performance[J]. Transactions of China Electrotechnical Society, 2011, 26(1): 170-176. [18] 孙才新, 舒立春, 蒋兴良, 等. 高海拔、污秽、覆冰环境条件下超高压线路绝缘子交直流放点特性及闪络电压校正研究[J]. 中国电机工程学报, 1999, 22(11): 115-120. Sun Caixin, Shu Lichun, Jiang Xingliang, et al. AC/DC flashover performance and its voltage correction of UHV insulators in high altitude and icing and pollution environments[J]. Proceedings of the CSEE, 1999, 22(11): 115-120. [19] Farzaneh M, Kienicki J. Ice accretion on energized line insulators[J]. International of Offshore and Polar Engineering, 1992, 2(3): 228-233. [20] Farzaneh M, Brettschneider S, Srivastava K D. Study of visible discharge onset and development on ice surfaces[C]. Conference Record of the 2000 IEEE International Symposium on Electrical Insulation, Anaheim, CA USA, 2000: 216-221. [21] 司马文霞, 蒋兴良, 武利会, 等. 低气压下覆冰染污10kV合成绝缘子直流电气特性[J]. 中国电机工程学报, 2004, 24(7): 121-126. Sima Wenxia, Jiang Xingliang, Wu Lihui, et al. DC electric performance of icing and polluted 10kV composite insulator at low atmospheric pressures[J]. Proceedings of the CSEE, 2004, 24(7): 121-126. [22] Farzaneh M, Drapeau J F. Ac flashover performance of insulators covered with artificial ice[J]. IEEE Transactions on Power Delivery, 1995, 10(2): 1038- 1051. [23] Jiang Xingliang, Chao Yafeng, Zhang Zhijin, et al. DC flashover performance and effect of sheds configuration on polluted and ice-covered composite insulators at low atmospheric pressure[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2011, 18(1): 97-105.