Abstract:Inadvertent islanding causes serious problems. For these reasons islanding detection is an indispensable feature for DG-systems. The Slip-mode frequency shift(SMS) method was discussed. And the non-detection zones of the SMS in Qf×f0 coordinate system was analyzed. In order to overcome the disadvantage of SMS, an adaptive sliding-mode frequency shift method is proposed. This method sets the starting angle. When the measured frequency deviation is beyond the error range, the maximum phase angle and starting angle will be increased in the positive feedback manner. Thus, the frequency deviation of point of common coupling is accelerated, and the time of islanding detection is shortened. The experimental results verified the validity of the proposed method.
刘鸿鹏, 吴辉, 王卫. 自适应滑模频移孤岛检测方法的研究[J]. 电工技术学报, 2013, 28(1增): 186-190.
Liu Hongpeng, Wu Hui, Wang Wei. Research on the Adaptive Slip-Mode Frequency Shift Method. Transactions of China Electrotechnical Society, 2013, 28(1增): 186-190.
[1] Moradzadeh M, Rajabzadeh M, Bathaee S M T. A novel hybrid islanding detection method for distributed generations[C]. The 3rd International Conference on Deregulation and Restructuring and Power Technologies, 2008: 2290-2295. [2] Mohamad H, Crossley P A. Islanded operation of UK radial distribution: earthing strategy[C]. The 44th International Universities Power Engineering Conference, Glasgow, 2009: 1-6. [3] 侯梅毅, 高厚磊, 刘炳旭, 等. 基于相位偏移的孤岛检测新方法[J]. 电力自动化设备, 2009, 29(11): 22-26. HouMeiyi, Gao Houlei, Liu Bingxu, et al. Islanding detection method based on phase shift[J]. Electric Power Automation Equipment,2009, 29(11): 22-26. [4] 张琦, 孙向东, 钟彦儒, 等. 用于分布式发电系统孤岛检测的偶次谐波电流扰动方法[J]. 电工技术学报, 2011, 26(7): 112-119. Zhang Qi, Sun Xiangdong, Zhong Yanru, et al. Even harmonic current distrbing method for islanding detection in the distributed power generation systems[J]. Tansactions of China Eletrotechnical Society, 2011, 26(7): 112-119. [5] Hernández-González Guillermo, Irvani Reza. Current injection for active islanding detection of electronically-interfaced distributed resources[J]. IEEE Transactions on Power Delivery, 2006, 21(3): 1978-1705. [6] Samuelsson O, Strath N. Islanding detection and connection requirements[C]. IEEE Power Engineering Society General Meeting, 2007: 1-6. [7] Mulhausen John, Schaefer Joe, Mynam Mangapathirao, et al. Anti-islanding today, successful islanding in the future[C]. The 63rd Annual Conference for Protective Relay Engineers, 2010: 1-8. [8] 关雅娟, 邬伟扬, 郭小强. 微电网中三相逆变器孤岛运行控制技术[J]. 中国电机工程学报, 2011, 31(33): 52-60. Guan Yajuan, Wu Weiyang, Guo Xiaoqiang. Control strategy for three-phase inverters dominated microgrid in autonomous operation[J]. Proceedings of the CSEE, 2011, 31(33): 52-60. [9] 龚会茹, 易灵芝, 深建飞, 等. 光伏并网系统中的新型孤岛检测方法[J]. 电力系统及其自动化学报, 2012, 24(1): 59-65. Gong Huiru, Yi Lingzhi, Shen Jianfei, et al. New island detection method of PV grid-connected system[J]. Proceedings of the Chinese Society of Universities for Electric Power System and its Automation, 2012, 24(1): 59-65. [10] Lee Soo Hyoung, Park Jung Wook. New islanding detection method for inverter-based distributed generation considering its switching frequency[J]. IEEE Transactions on Industry Applications, 2010, 46(5): 2089-2098. [11] Kim Jae Hyung, Kim Jun Gu, Ji Young Hyok, et al. An islanding detection method for a grid-connected system based on the goertzel algorithm[J]. IEEE Transactions on Power Electronics, 2011, 26(4): 1049-1055. [12] Esébanez E J, Moreno V M, Pigazo A, et al. Performance evaluation of active islanding-detection algorithms in distributed-generation photovoltaic systems: two inverters case[J]. IEEE Transactions on Industrial Electronics, 2011, 58(4): 1185-1193.